A non-enzymatic glucose sensor based on CuO-nanostructure modified carbon ceramic electrode

被引:27
|
作者
Rahim, Abdur [1 ]
Rehman, Zia Ur [2 ]
Mir, Sadullah [2 ]
Muhammad, Nawshad [1 ]
Rehman, Fozia [1 ]
Nawaz, Mian Hasnain [1 ]
Yaqub, Mustansara [1 ]
Siddiqi, Saadat Anwar [1 ]
Chaudhry, Aqif Anwar [1 ]
机构
[1] COMSATS Inst Informat Technol, Interdisciplinary Res Ctr Biomed Mat, Lahore, Pakistan
[2] COMSATS Inst Informat Technol, Dept Chem, Abbottabad, Pakistan
关键词
CuO; Glucose; Non-enzymatic; Nanocomposite; Sol-gel; Carbon ceramic material; SIO2/C ELECTRODE; IN-SITU; NANOPARTICLES; PHTHALOCYANINE; COMPOSITE; GRAPHENE; OXIDASE; FILM; IMMOBILIZATION; NANOCOMPOSITES;
D O I
10.1016/j.molliq.2017.10.087
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Mesoporous silica-graphite composite (SiO2/C-graphite) was synthesized by the sol-gel technique. The surface area (S-BET = 98.93 m(2)/g), pore volume (0.30 cm(3)/g) and pore size (12.16 nm) were characterized by BET. The novelty of this work lays in the fabrication of material in which ceramic material (SiO2/C-graphite) was decorated with copper oxide (CuO) nanostructure. SEM images revealed material compactness without phase segregation and EDX mapping showed a homogenous structure. Pressed disk electrode fabricated with SiO2/C/CuO nanocomposite material was evaluated as an amperometric non-enzymatic glucose sensor in 0.1 M NaOH solution. The linear response range, sensitivity, detection limit, and quantification limit were 0.0220.0 mmol L-1, 0.06 mu mol L-1, 472 mu A mmol(-1) L-1 cm(-2), and 0.76 mmol L-1, respectively. The electrode response time is < 1 s with the addition of 0.02 mmol L-1 glucose. The electrode is chemically stable, exhibits rapid and excellent sensitivity and does not show any interference from coexisting species present in the blood samples. The proposed sensor repeatability was assessed as 1.9% RSD for ten measurements of 13.0 mmol L-1 glucose solution. The sensor tested to ascertain glucose in blood serum showed to be a promising tool for the future evolution of non-enzymatic glucose sensors. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [41] A non-enzymatic photoelectrochemical glucose sensor based on BiVO4 electrode under visible light
    Wang, Shan
    Li, Shaoping
    Wang, Wenwen
    Zhao, Mengting
    Liu, Jiaofeng
    Feng, Haifeng
    Chen, Yiming
    Gu, Qi
    Du, Yi
    Hao, Weichang
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 291 : 34 - 41
  • [42] Non-enzymatic Sensing of Glucose Using Glassy Carbon Electrode Modified with Organometallic Complex of Nickel
    Ciszewski, Aleksander
    Stepniak, Izabela
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10): : 8298 - 8307
  • [43] Polyaniline/Cerium Oxide Hybrid Modified Carbon Paste Electrode for Non-Enzymatic Glucose Detection
    Zhang, Jie
    Guan, Panpan
    Li, Yongjian
    Li, Wei
    Guo, Qingping
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2016, 37 (07): : 985 - 986
  • [44] A novel non-enzymatic glucose electrochemical sensor based on CNF@Ni-Co layered double hydroxide modified glassy carbon electrode
    Fu, Rong
    Lu, Youlan
    Ding, Yaping
    Li, Li
    Ren, Zhongming
    Si, Xiaojing
    Wu, Qingsheng
    MICROCHEMICAL JOURNAL, 2019, 150
  • [45] An ultrasensitive non-enzymatic glucose sensors based on controlled petal-like CuO nanostructure
    Wang, Xiao
    Ge, Chuang-ye
    Chen, Ke
    Zhang, Yu Xin
    ELECTROCHIMICA ACTA, 2018, 259 : 225 - 232
  • [46] Non-Enzymatic Impedimetric Sensor Based on 3-Aminophenylboronic Acid Functionalized Screen-Printed Carbon Electrode for Highly Sensitive Glucose Detection
    Dorledo de Faria, Ricardo Adriano
    Iden, Hassan
    Dias Heneine, Luiz Guilherme
    Matencio, Tulio
    Messaddeq, Younes
    SENSORS, 2019, 19 (07)
  • [47] Non-Enzymatic Glucose Sensor Based on Copper Nanoparticles Modified Microelectrode
    Wang, Fang
    Sun, Xianping
    Chen, Yan
    Xie, Shijing
    Chen, Zilin
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2013, 5 (06) : 624 - 629
  • [48] A non-enzymatic glucose sensor based on NiO nanoparticles/functionalized SBA 15/MWCNT-modified carbon paste electrode
    Mehdi Baghayeri
    Alireza Sedrpoushan
    Alireza Mohammadi
    Masoud Heidari
    Ionics, 2017, 23 : 1553 - 1562
  • [49] MWCNT-ruthenium oxide composite paste electrode as non-enzymatic glucose sensor
    Tehrani, Ramin M. A.
    Ab Ghani, Sulaiman
    BIOSENSORS & BIOELECTRONICS, 2012, 38 (01) : 278 - 283
  • [50] Au nanoparticles modified CuO nanowireelectrode based non-enzymatic glucose detection with improved linearity
    Mishra, Ashwini Kumar
    Jarwal, Deepak Kumar
    Mukherjee, Bratindranath
    Kumar, Amit
    Ratan, Smrity
    Tripathy, Manas Ranjan
    Jit, Satyabrata
    SCIENTIFIC REPORTS, 2020, 10 (01)