A non-enzymatic glucose sensor based on CuO-nanostructure modified carbon ceramic electrode

被引:27
|
作者
Rahim, Abdur [1 ]
Rehman, Zia Ur [2 ]
Mir, Sadullah [2 ]
Muhammad, Nawshad [1 ]
Rehman, Fozia [1 ]
Nawaz, Mian Hasnain [1 ]
Yaqub, Mustansara [1 ]
Siddiqi, Saadat Anwar [1 ]
Chaudhry, Aqif Anwar [1 ]
机构
[1] COMSATS Inst Informat Technol, Interdisciplinary Res Ctr Biomed Mat, Lahore, Pakistan
[2] COMSATS Inst Informat Technol, Dept Chem, Abbottabad, Pakistan
关键词
CuO; Glucose; Non-enzymatic; Nanocomposite; Sol-gel; Carbon ceramic material; SIO2/C ELECTRODE; IN-SITU; NANOPARTICLES; PHTHALOCYANINE; COMPOSITE; GRAPHENE; OXIDASE; FILM; IMMOBILIZATION; NANOCOMPOSITES;
D O I
10.1016/j.molliq.2017.10.087
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Mesoporous silica-graphite composite (SiO2/C-graphite) was synthesized by the sol-gel technique. The surface area (S-BET = 98.93 m(2)/g), pore volume (0.30 cm(3)/g) and pore size (12.16 nm) were characterized by BET. The novelty of this work lays in the fabrication of material in which ceramic material (SiO2/C-graphite) was decorated with copper oxide (CuO) nanostructure. SEM images revealed material compactness without phase segregation and EDX mapping showed a homogenous structure. Pressed disk electrode fabricated with SiO2/C/CuO nanocomposite material was evaluated as an amperometric non-enzymatic glucose sensor in 0.1 M NaOH solution. The linear response range, sensitivity, detection limit, and quantification limit were 0.0220.0 mmol L-1, 0.06 mu mol L-1, 472 mu A mmol(-1) L-1 cm(-2), and 0.76 mmol L-1, respectively. The electrode response time is < 1 s with the addition of 0.02 mmol L-1 glucose. The electrode is chemically stable, exhibits rapid and excellent sensitivity and does not show any interference from coexisting species present in the blood samples. The proposed sensor repeatability was assessed as 1.9% RSD for ten measurements of 13.0 mmol L-1 glucose solution. The sensor tested to ascertain glucose in blood serum showed to be a promising tool for the future evolution of non-enzymatic glucose sensors. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [31] Electrodeposition of CuO from Cu-MOF on glassy carbon electrode: A non enzymatic sensor for glucose
    Arul, P.
    John, S. Abraham
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 61 - 69
  • [32] Non-enzymatic hydrogen peroxide sensor based on palladium-decorated poly(thionine) modified glassy carbon electrode
    Celebi, Mutlu Sonmez
    Kara, Songul Kirlak
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2024, 71 (05) : 482 - 492
  • [33] New CuO nanocomposite as non-enzymatic glucose biosensor
    Ghorbani, Mojtaba
    Tarlani, Aliakbar
    Taghvaei-Ganjali, Saeed
    Malekzade, Mercede
    NANOMEDICINE JOURNAL, 2025, 12 (02) : 252 - 261
  • [34] A non-enzymatic urea sensor based on the nickel sulfide/graphene oxide modified glassy carbon electrode
    Naik, T. S. Sunil Kumar
    Saravanan, S.
    Saravana, K. N. Sri
    Pratiush, Utkarsh
    Ramamurthy, Praveen C.
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 245
  • [35] Non-Enzymatic Glucose Sensor based on Electrodeposition of Platinum Particles on Polyaniline Modified Pt Electrode
    Malhotra, Shveta
    Tang, Yijun
    Varshney, Pradeep K.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 699 - 715
  • [36] A novel nonenzymatic sensor based on CuO nanoneedle/graphene/carbon nanofiber modified electrode for probing glucose in saliva
    Ye, Daixin
    Liang, Guohai
    Li, Huixiang
    Luo, Juan
    Zhang, Song
    Chen, Hui
    Kong, Julie
    TALANTA, 2013, 116 : 223 - 230
  • [37] Non-enzymatic glucose sensor with electrodeposited silver/carbon nanotubes composite electrode
    Shabbir, Syeda Ammara
    Tariq, Sana
    Ashiq, M. Gul Bahar
    Khan, Waqar A.
    BIOSCIENCE REPORTS, 2019, 39
  • [38] Highly sensitive non-enzymatic glucose sensor based on over-oxidized polypyrrole nanowires modified with Ni(OH)2 nanoflakes
    Yang, Jiao
    Cho, Misuk
    Pang, Changhyun
    Lee, Youngkwan
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 211 : 93 - 101
  • [39] Analysing the bifunctional ability of CuO/BiOBr/rGO as an electrode for non-enzymatic glucose sensor and supercapacitor
    AnnieCanisius, D.
    Jennifer, M. Joe Raja Ruban
    Rubana, M. Joe Raja
    Varghese, Davis
    Muthupandi, S.
    Madhavan, J.
    Raj, M. Victor Antony
    MATERIALS LETTERS, 2023, 346
  • [40] Preparation and performance of non-enzymatic glucose sensor electrode based on nanometer cuprous oxide
    Yu, Xiaojiao
    Zhang, Jie
    Tang, Xiyan
    Wei, Yuchen
    Kou, Song
    Niu, Jinfen
    Yao, Binghua
    NANOMATERIALS AND NANOTECHNOLOGY, 2018, 8