A non-enzymatic glucose sensor based on CuO-nanostructure modified carbon ceramic electrode

被引:27
|
作者
Rahim, Abdur [1 ]
Rehman, Zia Ur [2 ]
Mir, Sadullah [2 ]
Muhammad, Nawshad [1 ]
Rehman, Fozia [1 ]
Nawaz, Mian Hasnain [1 ]
Yaqub, Mustansara [1 ]
Siddiqi, Saadat Anwar [1 ]
Chaudhry, Aqif Anwar [1 ]
机构
[1] COMSATS Inst Informat Technol, Interdisciplinary Res Ctr Biomed Mat, Lahore, Pakistan
[2] COMSATS Inst Informat Technol, Dept Chem, Abbottabad, Pakistan
关键词
CuO; Glucose; Non-enzymatic; Nanocomposite; Sol-gel; Carbon ceramic material; SIO2/C ELECTRODE; IN-SITU; NANOPARTICLES; PHTHALOCYANINE; COMPOSITE; GRAPHENE; OXIDASE; FILM; IMMOBILIZATION; NANOCOMPOSITES;
D O I
10.1016/j.molliq.2017.10.087
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Mesoporous silica-graphite composite (SiO2/C-graphite) was synthesized by the sol-gel technique. The surface area (S-BET = 98.93 m(2)/g), pore volume (0.30 cm(3)/g) and pore size (12.16 nm) were characterized by BET. The novelty of this work lays in the fabrication of material in which ceramic material (SiO2/C-graphite) was decorated with copper oxide (CuO) nanostructure. SEM images revealed material compactness without phase segregation and EDX mapping showed a homogenous structure. Pressed disk electrode fabricated with SiO2/C/CuO nanocomposite material was evaluated as an amperometric non-enzymatic glucose sensor in 0.1 M NaOH solution. The linear response range, sensitivity, detection limit, and quantification limit were 0.0220.0 mmol L-1, 0.06 mu mol L-1, 472 mu A mmol(-1) L-1 cm(-2), and 0.76 mmol L-1, respectively. The electrode response time is < 1 s with the addition of 0.02 mmol L-1 glucose. The electrode is chemically stable, exhibits rapid and excellent sensitivity and does not show any interference from coexisting species present in the blood samples. The proposed sensor repeatability was assessed as 1.9% RSD for ten measurements of 13.0 mmol L-1 glucose solution. The sensor tested to ascertain glucose in blood serum showed to be a promising tool for the future evolution of non-enzymatic glucose sensors. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [1] Non-Enzymatic Glucose Sensor Based on Cu Electrode Modified with CuO Nanoflowers
    Song, Min-Jung
    Lee, Seung-Koo
    Kim, Jong-Hoon
    Lim, Dae-Soon
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (04) : B43 - B46
  • [2] Non-enzymatic Glucose Sensor Based on Nickel/Carbon Composite
    Marini, Silvia
    Ben Mansour, Nabil
    Hjiri, Mokhtar
    Dhahri, Ramzi
    El Mir, Lassaad
    Espro, Claudia
    Bonavita, Anna
    Galvagno, Signorino
    Neri, Giovanni
    Leonardi, Salvatore Gianluca
    ELECTROANALYSIS, 2018, 30 (04) : 727 - 733
  • [3] A Novel Non-Enzymatic Glucose Sensor Based on CuO-Graphene Nanocomposites
    Yu, Hong-Ying
    Xu, Miao-Qing
    Yu, Shu-Hong
    Zhao, Guang-Chao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (06): : 8050 - 8057
  • [4] Non-Enzymatic Amperometric Determination of Glucose by CuO Nanobelt Graphene Composite Modified Glassy Carbon Electrode
    Muralikrishna, Sreeramareddygari
    Sureshkumar, Kempahanumakkagari
    Yan, Zhou
    Fernandez, Carlos
    Ramakrishnappa, Thippeswamy
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (08) : 1632 - 1641
  • [5] Nanoporous CuO layer modified Cu electrode for high performance enzymatic and non-enzymatic glucose sensing
    Li, Changli
    Kurniawan, Mario
    Sun, Dali
    Tabata, Hitoshi
    Delaunay, Jean-Jacques
    NANOTECHNOLOGY, 2015, 26 (01)
  • [6] Facile fabrication of CuO nanowire modified Cu electrode for non-enzymatic glucose detection with enhanced sensitivity
    Ni, Pengjuan
    Sun, Yujing
    Shi, Yan
    Dai, Haichao
    Hu, Jingting
    Wang, Yilin
    Li, Zhuang
    RSC ADVANCES, 2014, 4 (55) : 28842 - 28847
  • [7] A Sensitive and Selective Non-Enzymatic Glucose Sensor based on AuNPs/CuO NWs-MoS2 Modified Electrode
    Bao, Jing
    Qi, Yanli
    Huo, Danqun
    Hou, Jingzhou
    Geng, Xintong
    Samalo, Mickey
    Liu, Zishan
    Luo, Huibo
    Yang, Mei
    Hou, Changjun
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (13) : B1179 - B1185
  • [8] Non-Enzymatic Amperometric Glucose Sensor Based on Carbon Nanodots and Copper Oxide Nanocomposites Electrode
    Sridara, Tharinee
    Upan, Jantima
    Saianand, Gopalan
    Tuantranont, Adisorn
    Karuwan, Chanpen
    Jakmunee, Jaroon
    SENSORS, 2020, 20 (03)
  • [9] Non-enzymatic glucose sensor based on facial hydrothermal synthesized NiO nanosheets loaded on glassy carbon electrode
    Wang, Shutao
    Wang, Cong
    Wei, Guijuan
    Xiao, Huaqing
    An, Ning
    Zhou, Yan
    An, Changhua
    Zhang, Jun
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2016, 509 : 252 - 258
  • [10] A sensitive non-enzymatic glucose sensor in alkaline media based on Cu/MnO2-modified glassy carbon electrode