LOW-DOSE CT IMAGE RECONSTRUCTION BASED ON WAVELET-TGV AND NON-CONVEX PENALTY FUNCTION

被引:0
|
作者
Zhang, Wei [1 ,2 ,3 ,4 ]
Chen, Xiaozhao [1 ,2 ,3 ,4 ]
Wang, Haiyan [1 ,2 ,3 ,4 ]
Kang, Yan [1 ,2 ,3 ,4 ]
机构
[1] Jilin Normal Univ, Coll Comp, Siping 136000, Peoples R China
[2] Shenyang Pharmaceut Univ, Coll Med Device, Shenyang 110016, Peoples R China
[3] Changchun Univ, Coll Comp Sci & Technol, Changchun 130022, Peoples R China
[4] Minist Educ, Engn Res Ctr Med Imaging & Intelligent Anal, Shenyang 110169, Peoples R China
关键词
Low-dose CT; image reconstruction; denoising; wavelet; total generalized variation; REGULARIZATION; RESTORATION;
D O I
暂无
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Reducing the computed tomography (CT) scanning dose decreases the risk of cancer; however, low-dose imaging is accompanied by a high level of noise. The present paper focuses on the noise statistical characteristics of low-dose CT projection data and establishes a low-dose CT projection domain denoising based on wavelet-total generalized variation (wavelet-TGV) and non-convex penalty function with a view to promoting the quality of reconstructed images. The model utilizes the high-order derivative information of the total generalized variation, which can avoid the staircase effect and block artifacts introduced by the TV minimizing denoising process, further enhancing the sparseness of the objective function under the constraints of the non-convex penalty function. The Split Augmented Lagrange Shrinkage algorithm was exploited to optimize the solution, and the reconstructed results of the proposed denoising method were experimentally compared with those of other methods. In terms of visual effects and quantitative analysis, we demonstrate that the quality of the image reconstructed using the present denoising method can be significantly improved while preserving the boundary and textural details.
引用
收藏
页码:2219 / 2230
页数:12
相关论文
共 50 条
  • [1] Total variation image reconstruction algorithm based on non-convex function
    Bi, Shaojiu
    Li, Minmin
    Cai, Guangcheng
    Zhang, Xi
    SIGNAL IMAGE AND VIDEO PROCESSING, 2024, 18 (05) : 4491 - 4503
  • [2] Low-dose CT reconstruction using spatially encoded nonlocal penalty
    Kim, Kyungsang
    El Fakhri, Georges
    Li, Quanzheng
    MEDICAL PHYSICS, 2017, 44 (10) : e376 - e390
  • [3] Deep Learning With Adaptive Hyper-Parameters for Low-Dose CT Image Reconstruction
    Ding, Qiaoqiao
    Nan, Yuesong
    Gao, Hao
    Ji, Hui
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2021, 7 : 648 - 660
  • [4] Prior-image-based low-dose CT reconstruction for adaptive radiation therapy
    Xu, Yao
    Wang, Jiazhou
    Hu, Weigang
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (21)
  • [5] A non-smooth and non-convex regularization method for limited-angle CT image reconstruction
    Zhang, Lingli
    Zeng, Li
    Wang, Chengxiang
    Guo, Yumeng
    JOURNAL OF INVERSE AND ILL-POSED PROBLEMS, 2018, 26 (06): : 799 - 820
  • [6] Unbiased statistical image reconstruction in low-dose CT
    Hayes, John
    Zhang, Ran
    Zhang, Chengzhu
    Gomez-Cardona, Daniel
    Chen, Guang-Hong
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [7] Non-convex primal-dual algorithm for image reconstruction in spectral CT
    Chen, Buxin
    Zhang, Zheng
    Xia, Dan
    Sidky, Emil Y.
    Pan, Xiaochuan
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2021, 87
  • [8] Statistical image reconstruction for low-dose CT using nonlocal means-based regularization
    Zhang, Hao
    Ma, Jianhua
    Wang, Jing
    Liu, Yan
    Lu, Hongbing
    Liang, Zhengrong
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2014, 38 (06) : 423 - 435
  • [9] Iterative reconstruction of low-dose CT based on differential sparse
    Lu, Siyu
    Yang, Bo
    Xiao, Ye
    Liu, Shan
    Liu, Mingzhe
    Yin, Lirong
    Zheng, Wenfeng
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [10] Low-dose CT reconstruction method based on prior information of normal-dose image
    Chen, Zixiang
    Zhang, Qiyang
    Zhou, Chao
    Zhang, Mengxi
    Yang, Yongfeng
    Liu, Xin
    Zheng, Hairong
    Liang, Dong
    Hu, Zhanli
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (06) : 1091 - 1111