Determination of Trace Perchlorate Concentrations by Anion-Selective Membranes and Total Reflection X-ray Fluorescence Analysis

被引:36
作者
Hatzistavros, Vasilios S. [1 ]
Kallithrakas-Kontos, Nikolaos G. [1 ]
机构
[1] Tech Univ Crete, Analyt & Environm Chem Lab, GR-73100 Khania, Greece
关键词
COMPLEX;
D O I
10.1021/ac103295a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work a method for the determination of perchlorate trace levels by total reflection X-ray fluorescence (TXRF) is introduced. Perchlorate anions were concentrated on anion-selective membranes that had been prepared on the surface of TXRF quartz reflectors. Various complexation substances were used in the membranes. The reflectors were immersed in water solutions containing nanogram per milliliter (ppb) concentrations of perchlorate. After this step, the reflectors were taken out of the solution and they were analyzed by TXRF, using a copper X-ray tube and helium flow on the target (to lower the argon peak which is present in the air). The effects of various experimental parameters were examined, and the possibility of discrimination between chloride and perchlorate anions was shown. Minimum detection limits lower than 1 ng/mL and good linearity at the concentration range of 1-50 ng/mL were achieved. The method is applicable for the analysis of perchlorate in drinking water samples.
引用
收藏
页码:3386 / 3391
页数:6
相关论文
共 23 条
  • [1] [Anonymous], HLTH IMPL PERCHL ING
  • [2] ION CHROMATOGRAPHIC DETERMINATION OF PERCHLORATE IN CATTLE URINE
    BATJOENS, P
    DEBRABANDER, HF
    TKINDT, L
    [J]. ANALYTICA CHIMICA ACTA, 1993, 275 (1-2) : 335 - 340
  • [3] CLARK JJJ, 2000, PERCHLORATE ENV, pCH3
  • [4] Gallego M., 1998, ANAL CHIM ACTA, V98, P1593
  • [5] Bromate determination in water after membrane complexation and total reflection X-ray fluorescence analysis
    Hatzistavros, Vasilios S.
    Koulouridakis, Pavlos E.
    Aretaki, Ioanna I.
    Kallithrakas-Kontos, Nikolaos G.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (07) : 2827 - 2832
  • [6] Highly selective thiocyanate electrode based on bis-[N-(2-hydroxyethyl)salicylaldimino]copper(II) complex as a neutral carrier
    Huang, XQ
    Chai, YQ
    Yuan, R
    Wang, XL
    Li, QF
    [J]. ANALYTICAL SCIENCES, 2004, 20 (08) : 1185 - 1188
  • [7] Perchlorate in milk
    Kirk, AB
    Smith, EE
    Tian, K
    Anderson, TA
    Dasgupta, PK
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (21) : 4979 - 4981
  • [8] Neonatal thyroxine level and perchlorate in drinking water
    Li, Z
    Li, FX
    Byrd, D
    Deyhle, GM
    Sesser, DE
    Skeels, MR
    Lamm, SH
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2000, 42 (02) : 200 - 205
  • [9] Perchlorate: Problems, detection, and solutions
    Motzer, WE
    [J]. ENVIRONMENTAL FORENSICS, 2001, 2 (04) : 301 - 311
  • [10] Water analysis: Emerging contaminants and current issues
    Richardson, Susan D.