Performance analysis of an irreversible cogeneration heat pump cycle

被引:0
|
作者
Göktun, S [1 ]
机构
[1] ITU, Maritime Fac, Dept Marine Engn, TR-81716 Tuzla Istanbul, Turkey
关键词
cogeneration; heat pump; irreversible; coefficient of performance;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An irreversible heat engine-driven vapour compression and absorption heat pump system is considered as a cogeneration cycle. The effects of thermal resistances and internal irreversibilities on the coefficient of performance (COP) of this cogeneration cycle were investigated using finite-time thermodynamic approach. An improved equation for the COP of the system under consideration was obtained. The results obtained here may serve as a good guide for the evaluation of existing real cogeneration heat pumps or provide some theoretical bases for the optimal design of future cogeneration heat pumps. (C) 1998 John Wiley & Sons, Ltd.
引用
收藏
页码:1299 / 1304
页数:6
相关论文
共 50 条
  • [1] Optimum performance of an irreversible solar-driven cogeneration heat pump system
    Er, D
    Göktun, S
    ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (03) : 329 - 337
  • [2] Performance analysis of heat pump cycle with an expander
    Xue, Guijun
    Liang, Dawei
    Liu, Guangda
    Li, Shuiqing
    Zhou, Zhenjiang
    Xu, Fang
    Ye, Yunwang
    INFORMATION TECHNOLOGY APPLICATIONS IN INDUSTRY II, PTS 1-4, 2013, 411-414 : 3006 - 3009
  • [3] Thermodynamic analysis and optimization for an irreversible heat pump working on reversed Brayton cycle
    Ahmadi, Mohammad H.
    Ahmadi, Mohammad-Ali
    Pourfayaz, Fathollah
    Bidi, Mokhtar
    ENERGY CONVERSION AND MANAGEMENT, 2016, 110 : 260 - 267
  • [4] Performance analysis of irreversible energy selective electron (ESE) heat pump with heat leakage
    Ding, Z. M.
    Chen, L. G.
    Sun, F. R.
    JOURNAL OF THE ENERGY INSTITUTE, 2012, 85 (04) : 227 - 235
  • [5] General thermodynamic performance of irreversible absorption heat pump
    Zhao Xiling
    Fu Lin
    Zhang Shigang
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) : 494 - 499
  • [6] Thermodynamic Analysis of Irreversible Reversed Brayton Cycle Heat Pump with Finite Capacity Finite Conductance Heat Reservoirs
    Mundhra, Raghav
    Mukhopadhyay, Achintya
    ADVANCES IN MECHANICAL ENGINEERING, ICRIDME 2018, 2020, : 763 - 775
  • [7] Performance of cogeneration system incorporating gas engine driven heat pump
    Xie, Yingbai
    Lun, Liyong
    Yu, Zhun
    Zhang, Xuedong
    CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 61 - 63
  • [8] Thermal performance of a packed bed reactor of a chemical heat pump for cogeneration
    Kato, Y
    Takahashi, F
    Watanabe, A
    Yoshizawa, Y
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A5) : 745 - 748
  • [9] Performance Analysis of an Air Cycle Heat Pump with a Turbocharger Driven by a Blower
    Zhang, Qiuchen
    Wang, Shugang
    Li, Shuangshuang
    Wang, Jihong
    Zhang, Tengfei
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2720 - 2727
  • [10] Exergetic efficiency optimization for an irreversible heat pump working on reversed Brayton cycle
    Yuehong Bi
    Lingen Chen
    Fengrui Sun
    Pramana, 2010, 74 : 351 - 363