Fluid and White Matter Suppression New Sensitive 3 T Magnetic Resonance Imaging Contrasts for Cortical Lesion Detection in Multiple Sclerosis

被引:8
作者
Muller, Jannis [1 ,2 ,3 ,4 ]
La Rosa, Francesco [5 ,6 ]
Beaumont, Jeremy [7 ,8 ]
Tsagkas, Charidimos [1 ,2 ,3 ,4 ]
Rahmanzadeh, Reza [1 ,2 ]
Weigel, Matthias [1 ,2 ,3 ,4 ,9 ]
Bach Cuadra, Meritxell [6 ,10 ,11 ]
Gambarota, Giulio [7 ]
Granziera, Cristina [1 ,2 ,3 ,4 ]
机构
[1] Univ Hosp Basel, Fac Med, Dept Biomed Engn, Translat Imaging Neurol ThINk Basel, Basel, Switzerland
[2] Univ Basel, Petersgraben 4, CH-4031 Basel, Switzerland
[3] Univ Hosp Basel, MS Ctr, Neurol Clin & Policlin, Petersgraben 4, CH-4031 Basel, Switzerland
[4] Univ Hosp Basel, Res Ctr Clin Neuroimmunol & Neurosci Basel RC2NB, Petersgraben 4, CH-4031 Basel, Switzerland
[5] Ecole Polytech Fed Lausanne, Signal Proc Lab LTS5, Lausanne, Switzerland
[6] CIBM Ctr Biomed Imaging, Lausanne, Switzerland
[7] Univ Rennes, INSERM, UMR1099, LTSI, Rennes, France
[8] CSIRO, Australian E Hlth Res Ctr, Brisbane, Qld, Australia
[9] Univ Hosp Basel, Dept Radiol, Div Radiol Phys, Basel, Switzerland
[10] Lausanne Univ, Radiol Dept, Lausanne, Switzerland
[11] Univ Hosp, Lausanne, Switzerland
关键词
cortical lesions; FLAWS; FLAWS(hco); FLAWS(min); multiple sclerosis; MRI; MP2RAGE; T1; mapping; 3; T; INTRACORTICAL LESIONS; INVERSION-RECOVERY; MRI; RECOMMENDATIONS; VISUALIZATION; IMPROVES; TISSUE; PHASE;
D O I
10.1097/RLI.0000000000000877
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Cortical lesions are common in multiple sclerosis (MS), but their visualization is challenging on conventional magnetic resonance imaging. The uniform image derived from magnetization prepared 2 rapid acquisition gradient echoes (MP2RAGE(uni)) detects cortical lesions with a similar rate as the criterion standard sequence, double inversion recovery. Fluid and white matter suppression (FLAWS) provides multiple reconstructed contrasts acquired during a single acquisition. These contrasts include FLAWS minimum image (FLAWS(min)), which provides an exquisite sensitivity to the gray matter signal and therefore may facilitate cortical lesion identification, as well as high contrast FLAWS (FLAWS(hco)), which gives a contrast that is similar to one of MP2RAGE(uni). In this study, we compared the manual detection rate of cortical lesions on MP2RAGE(uni), FLAWS(min), and FLAWS(hco) in MS patients. Furthermore, we assessed whether the combined detection rate on FLAWS(min) and FLAWS(hco) was superior to MP2RAGE(uni) for cortical lesions identification. Last, we compared quantitative T1 maps (qT1) provided by both MP2RAGE and FLAWS in MS lesions. Materials and Methods We included 30 relapsing-remitting MS patients who underwent MP2RAGE and FLAWS magnetic resonance imaging with isotropic spatial resolution of 1 mm at 3 T. Cortical lesions were manually segmented by consensus of 3 trained raters and classified as intracortical or leukocortical lesions on (1) MP2RAGE uniform/flat images, (2) FLAWS(min), and (3) FLAWS(hco). In addition, segmented lesions on FLAWS(min) and FLAWS(hco) were merged to produce a union lesion map (FLAWS(min + hco)). Number and volume of all cortical, intracortical, and leukocortical lesions were compared among MP2RAGE(uni), FLAWS(min), and FLAWS(hco) using Friedman test and between MP2RAGE(uni) and FLAWS(min + hco) using Wilcoxon signed rank test. The FLAWS T1 maps were then compared with the reference MP2RAGE T1 maps using relative differences in percentage. In an exploratory analysis, individual cortical lesion counts of the 3 raters were compared, and interrater variability was quantified using Fleiss K. Results In total, 633 segmentations were made on the 3 contrasts, corresponding to 355 cortical lesions. The median number and volume of single cortical, intracortical, and leukocortical lesions were comparable among MP2RAGE(uni), FLAWS(min), and FLAWS(hco). In patients with cortical lesions (22/30), median cumulative lesion volume was larger on FLAWS(min) (587 mu L; IQR, 1405 mu L) than on MP2RAGE(uni) (490 mu L; IQR, 990 mu L; P = 0.04), whereas there was no difference between FLAWS(min) and FLAWS(hco), or FLAWS(hco) and MP2RAGE(uni). FLAWS(min + hco) showed significantly greater numbers of cortical (median, 4.5; IQR, 15) and leukocortical (median, 3.5; IQR, 12) lesions than MP2RAGE(uni) (median, 3; IQR, 10; median, 2.5; IQR, 7; both P < 0.001). Interrater agreement was moderate on MP2RAGE(uni) (K = 0.582) and FLAWS(hco) (K = 0.584), but substantial on FLAWS(min) (K = 0.614). qT1 in lesions was similar between MP2RAGE and FLAWS. Conclusions Cortical lesions identification in FLAWS(min) and FLAWS(hco) was comparable to MP2RAGE(uni). The combination of FLAWS(min) and FLAWS(hco) allowed to identify a higher number of cortical lesions than MP2RAGE(uni), whereas qT1 maps did not differ between the 2 acquisition schemes.
引用
收藏
页码:592 / 600
页数:9
相关论文
共 40 条
[1]  
Avants B, 2009, INSIGHT J, DOI 10.54294/uvnhin
[2]   Multi T1-weighted contrast MRI with fluid and white matter suppression at 1.5 T [J].
Beaumont, J. ;
Saint-Jalmes, H. ;
Acosta, O. ;
Kober, T. ;
Tanner, M. ;
Ferre, J. C. ;
Salvado, O. ;
Fripp, J. ;
Gambarota, G. .
MAGNETIC RESONANCE IMAGING, 2019, 63 :217-225
[3]  
Beaumont J., 2019, ISBI 2019 16 IEEE IN
[4]  
Beaumont J., BIORXIV, DOI [10.1101/2021.12.18.473283, DOI 10.1101/2021.12.18.473283]
[5]   High-resolution multi-T1-weighted contrast and T1mapping with lowB1>+sensitivity using the fluid and white matter suppression (FLAWS) sequence at 7T [J].
Beaumont, Jeremy ;
Gambarota, Giulio ;
Saint-Jalmes, Herve ;
Acosta, Oscar ;
Ferre, Jean-Christophe ;
Raniga, Parnesh ;
Fripp, Jurgen .
MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) :1364-1378
[6]   Improved Visualization of Cortical Lesions in Multiple Sclerosis Using 7T MP2RAGE [J].
Beck, E. S. ;
Sati, P. ;
Sethi, V. ;
Kober, T. ;
Dewey, B. ;
Bhargava, P. ;
Nair, G. ;
Cortese, I. C. ;
Reich, D. S. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (03) :459-466
[7]   Inversion Recovery Susceptibility Weighted Imaging With Enhanced T2 Weighting at 3 T Improves Visualization of Subpial Cortical Multiple Sclerosis Lesions [J].
Beck, Erin S. ;
Gai, Neville ;
Filippini, Stefano ;
Maranzano, Josefina ;
Nair, Govind ;
Reich, Daniel S. .
INVESTIGATIVE RADIOLOGY, 2020, 55 (11) :727-735
[8]   The combined Quantification and interpretation of Multiple Quantitative Magnetic resonance imaging Metrics enlightens longitudinal changes compatible with Brain repair in relapsing-remitting Multiple sclerosis Patients [J].
Bonnier, Guillaume ;
Marechal, Benedicte ;
Fartaria, Mario Joao ;
Falkowskiy, Pavel ;
Marques, Jose P. ;
Simioni, Samanta ;
Schluep, Myriam ;
Du Pasquier, Renaud ;
Thiran, Jean-Philippe ;
Krueger, Gunnar ;
Granziera, Cristina .
FRONTIERS IN NEUROLOGY, 2017, 8
[9]   Advanced MRI unravels the nature of tissue alterations in early multiple sclerosis [J].
Bonnier, Guillaume ;
Roche, Alexis ;
Romascano, David ;
Simioni, Samanta ;
Meskaldji, Djalel ;
Rotzinger, David ;
Lin, Ying-Chia ;
Menegaz, Gloria ;
Schluep, Myriam ;
Du Pasquier, Renaud ;
Sumpf, Tilman Johannes ;
Frahm, Jens ;
Thiran, Jean-Philippe ;
Krueger, Gunnar ;
Granziera, Cristina .
ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2014, 1 (06) :423-432
[10]   Histopathology-validated recommendations for cortical lesion imaging in multiple sclerosis [J].
Bouman, Piet M. ;
Steenwijk, Martijn D. ;
Pouwels, Petra J. W. ;
Schoonheim, Menno M. ;
Barkhof, Frederik ;
Jonkman, Laura E. ;
Geurts, Jeroen J. G. .