Glycated albumin and continuous glucose monitoring metrics across pregnancy in women with pre-gestational diabetes

被引:4
作者
Toft, Johanne Holm [1 ,2 ]
Dalen, Ingvild [3 ]
Skadberg, Oyvind [4 ]
Goransson, Lasse Gunnar [5 ,6 ]
Okland, Inger [1 ,7 ]
Bleskestad, Inger Hjordis [5 ]
机构
[1] Stavanger Univ Hosp, Dept Obstet & Gynecol, POB 8100, N-4068 Stavanger, Norway
[2] Univ Bergen, Dept Clin Sci, Bergen, Norway
[3] Stavanger Univ Hosp, Dept Res, Sect Biostat, Stavanger, Norway
[4] Stavanger Univ Hosp, Dept Med Biochem, Stavanger, Norway
[5] Stavanger Univ Hosp, Dept Internal Med, Stavanger, Norway
[6] Univ Bergen, Dept Clin Med, Bergen, Norway
[7] Univ Stavanger, Dept Caring & Eth, Stavanger, Norway
关键词
continuous glucose monitoring; glycated albumin; glycated haemoglobin A1c; pregnancy; type; 1; diabetes; 2; REFERENCE INTERVALS; HEMOGLOBIN LEVELS; HBA(1C); BIRTH; SERUM; A1C;
D O I
10.1002/edm2.376
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Glycated albumin (GA), a biomarker reflecting short-term glycaemia, may be useful to assess glycaemic control in pregnancy. We examined the association between GA and continuous glucose monitoring (CGM) metrics across gestation. Methods In this prospective cohort study including 40 women with pre-gestational diabetes, blood samples for analysis of GA and glycated haemoglobin A1c (HbA1c) were collected at pregnancy week 12, 20, 24, 28, 32 and 36. In the CGM-group (n = 19), CGM data were collected from first trimester until pregnancy week 36. Receiver operating characteristic (ROC) curves were used to assess the accuracy of GA and HbA1c to detect poor glycaemic control, using CGM metrics as the reference standard. This study was conducted at Stavanger University Hospital, Norway, in 2016-2018. Results Glycaemic control improved across gestation with more time spent in target range, coinciding with decreased glycaemic variability and lower mean GA level. There was statistically significant correlation between GA and most CGM metrics. The area under the ROC curves (AUC) for detecting time in range 25% for the pregnancy glucose target 63-140 mg/dl (3.5-7.8 mmol/L) were 0.78 and 0.82 for GA, whereas AUCs of 0.60 and 0.72 were found for HbA1c, respectively. Conclusions Higher GA levels were associated with less time spent in target range, more time spent in the above range area and increased glycaemic variability. GA was more accurate than HbA1c to detect time above range >25% and time in range <70%.
引用
收藏
页数:11
相关论文
共 30 条
[21]   Relationship between glycated haemoglobin levels and mean glucose levels over time [J].
Nathan, D. M. ;
Turgeon, H. ;
Regan, S. .
DIABETOLOGIA, 2007, 50 (11) :2239-2244
[22]   Diabetes Advances in Diagnosis and Treatment [J].
Nathan, David M. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2015, 314 (10) :1052-1062
[23]  
Norwegian Directorate of Health, 2016, NATL GUIDELINE DIABE
[24]  
Panyakat Wanwadee Sapmee, 2018, J Diabetes Sci Technol, V12, P622, DOI 10.1177/1932296817752374
[25]   ADIPS 2020 guideline for pre-existing diabetes and pregnancy [J].
Rudland, Victoria L. ;
Price, Sarah A. L. ;
Hughes, Ruth ;
Barrett, Helen L. ;
Lagstrom, Janet ;
Porter, Cynthia ;
Britten, Fiona L. ;
Glastras, Sarah ;
Fulcher, Ian ;
Wein, Peter ;
Simmons, David ;
McIntyre, H. David ;
Callaway, Leonie .
AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2020, 60 (06) :E18-E52
[26]   Closed-Loop Insulin Delivery during Pregnancy in Women with Type 1 Diabetes [J].
Stewart, Zoe A. ;
Wilinska, Malgorzata E. ;
Hartnell, Sara ;
Temple, Rosemary C. ;
Rayman, Gerry ;
Stanley, Katharine P. ;
Simmons, David ;
Law, Graham R. ;
Scott, Eleanor M. ;
Hovorka, Roman ;
Murphy, Helen R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (07) :644-654
[27]   Complications in Infants of Diabetic Mothers Related to Glycated Albumin and Hemoglobin Levels During Pregnancy [J].
Sugawara, Daisuke ;
Maruyama, Asami ;
Imanishi, Toshiyuki ;
Sugiyama, Yohei ;
Ichihashi, Ko .
PEDIATRICS AND NEONATOLOGY, 2016, 57 (06) :496-500
[28]   Glycated albumin in pregnancy: LC-MS/MS-based reference interval in healthy, nulliparous Scandinavian women and its diagnostic accuracy in gestational diabetes mellitus [J].
Toft, Johanne Holm ;
Bleskestad, Inger Hjordis ;
Skadberg, Oyvind ;
Goransson, Lasse Gunnar ;
Okland, Inger .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2022, 82 (02) :123-131
[29]   Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System During 10 Days of Use in Youth and Adults with Diabetes [J].
Wadwa, R. Paul ;
Laffel, Lori M. ;
Shah, Viral N. ;
Garg, Satish K. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (06) :395-402
[30]  
WHO, 2011, WORLD REPORT ON DISABILITY, P1