The graft/tunnel angles in posterior cruciate ligament reconstruction: A cadaveric comparison of two techniques for femoral tunnel placement

被引:38
作者
Handy, MH [1 ]
Blessey, PB [1 ]
Kline, AJ [1 ]
Miller, MD [1 ]
机构
[1] Univ Virginia, Hlth Syst, Dept Orthopaed, Charlottesville, VA 22908 USA
关键词
PCL; killer turn; critical corner; failure; biomechanics; angle;
D O I
10.1016/j.arthro.2005.03.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: In posterior cruciate ligament reconstruction, the tibial tunnel/graft angle (or killer turn) has been implicated in graft failure when using transtibial tunnel placement. The graft/femoral tunnel angle (or critical corner) can also contribute to shear stress and early graft failure. The purpose of this study was to quantitate the killer turn angle in flexion and extension and to compare critical corner angles using outside-in and inside-out techniques for femoral tunnel placement. Type of Study: A cadaveric, biomechanical comparison. Methods: One transtibial tunnel and 2 femoral tunnels were marked with guidewires in 9 fresh-frozen cadaveric knees. The killer turn and the 2 critical corner angles were measured at 90 degrees of flexion and full extension on fluoroscopic images. Results were analyzed using a Student t test with paired data. Results: The average killer turn was 70 degrees +/- 12 degrees and 78 degrees +/- 7 degrees in flexion and extension, respectively. Knee extension significantly increased the killer turn angle (P = .048). The average critical corner was 50 degrees +/- 16 degrees and -14 degrees +/- 18 degrees with the outside-in technique versus 87 degrees +/- 8 degrees and 27 degrees +/- 14 degrees with the inside-out technique in flexion and extension, respectively. The inside-out technique significantly increased the critical corner in flexion (P = .00007) and extension (P = .00005). At 901 of flexion, the critical corner angle using the inside-out technique significantly exceeded the killer turn angle (P = .003). Conclusions: We recommend the outside-in technique for femoral tunnel placement to reduce the graft/femoral tunnel angle. Using the inside-out technique can significantly sharpen the critical corner, causing it to exceed the killer turn in flexion. Clinical Relevance: This study indicates that significantly lower graft/femoral tunnel angles can be obtained when using the outside-in technique for femoral tunnel placement when compared with the inside-out technique. This may translate to lower rates of graft failure in clinical application, although further clinical studies are needed.
引用
收藏
页码:711 / 714
页数:4
相关论文
共 7 条
[1]   A biomechanical comparison of posterior cruciate ligament reconstruction techniques [J].
Bergfeld, JA ;
McAllister, DR ;
Parker, RD ;
Valdevit, ADC ;
Kambic, HE .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2001, 29 (02) :129-136
[2]   Arthroscopic double-bundled posterior cruciate ligament reconstruction with quadriceps tendon-patellar bone autograft [J].
Chen, CH ;
Chen, WJ ;
Shih, CH .
ARTHROSCOPY, 2000, 16 (07) :780-782
[3]   Magnetic resonance imaging of tunnel placement in posterior cruciate ligament reconstruction [J].
Mariani, PP ;
Adriani, E ;
Bellelli, A ;
Maresca, G .
ARTHROSCOPY, 1999, 15 (07) :733-740
[4]   Cyclic loading of posterior cruciate ligament replacements fixed with tibial tunnel and tibial inlay methods [J].
Markolf, KL ;
Zemanovic, JR ;
McAllister, DR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (04) :518-524
[5]  
Miller Mark D, 2002, Instr Course Lect, V51, P347
[6]   A new endoscopic posterior cruciate ligament reconstruction: Minimization of graft angulation [J].
Ohkoshi, Y ;
Nagasaki, S ;
Yamamoto, K ;
Urushibara, M ;
Tada, H ;
Shigenobu, K ;
Hashimoto, T ;
Yamane, S .
ARTHROSCOPY, 2001, 17 (03) :258-263
[7]   Arthroscopic posterior cruciate ligament reconstruction using hamstring tendons: One-incision technique with EndoButton [J].
Shino, K ;
Nakagawa, S ;
Nakamura, N ;
Matsumoto, N ;
Toritsuka, Y ;
Natsuume, T .
ARTHROSCOPY, 1996, 12 (05) :638-642