Minimizing fuel and environmental costs for a variable-load power, plant (co-)firing fuel oil and natural gas - Part 2. Optimization of load dispatch

被引:7
作者
Kuprianov, V. I. [1 ]
Kaewboonsong, W. [1 ]
Douglas, P. L. [2 ]
机构
[1] Thammasat Univ, Sirindhorn Int Inst Technol, Sch Mfg Syst & Mech Engn, Pathum Thani 12121, Thailand
[2] Univ Waterloo, Dept Chem Engn, Waterloo, ON N2L 3G1, Canada
关键词
boiler units; fuel and emission rates; total costs; cost savings;
D O I
10.1016/j.fuproc.2007.07.001
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A linear programming-based approach was applied to optimize the power (or load) distribution among 200-MW and 310-MW units of a 1330-MW power plant (co-)firing fuel oil and natural gas. The objective function for the optimization was the total costs, including "internal" (or fuel) and "external" (or environmental) costs, for the power plant meeting the current load demand. Both fuel and environmental costs (the latter being associated with NOx, SO3, SO2 and CO2 emissions) of the units were predicted for different fuel options. The total costs for an individual boiler unit were shown to be quasi-linear with the unit load. Optimal load dispatch over the units was determined using a typical daily load curve of the power plant, for distinct climatic seasons in Thailand. The time-domain savings of the total costs resulted from switching the units from actual to the optimized loads were quantified for this power plant. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 14 条
[1]   Emission constrained secure economic dispatch [J].
Arya, LD ;
Choube, SC ;
Kothari, DP .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1997, 19 (05) :279-285
[2]  
*ESCAP UN, 1995, EN EFF
[3]   Minimizing fuel and environmental costs for a variable-load power plant (co-)firing fuel oil and natural gas - Part 1. Modeling of gaseous emissions from boiler units [J].
Kaewboonsong, W. ;
Kuprianov, V. I. ;
Chovichien, N. .
FUEL PROCESSING TECHNOLOGY, 2006, 87 (12) :1085-1094
[4]  
KAEWBOONSONG W, 2003, MACRO REV, V16, P83
[5]   Applications of a cost-based method of excess air optimization for the improvement of thermal efficiency and environmental performance of steam boilers [J].
Kuprianov, VI .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2005, 9 (05) :474-498
[6]  
Kuznetsov N. V., 1973, THERMAL CALCULATION
[7]   EMISSION DISPATCH MODELS AND ALGORITHMS FOR THE 1990S [J].
LAMONT, JW ;
OBESSIS, EV .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (02) :941-947
[8]   Fuzzy model-based optimal dispatching for NOx reduction in power plants [J].
Liu, ZP ;
Huang, YL .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1998, 20 (03) :169-176
[9]  
Muslu M, 2004, ELECTR POW SYST RES, V71, P153, DOI 10.1016/j.epsr.2004.01.009
[10]   Real-time economic dispatch using merit order loading for linear decreasing and staircase incremental cost functions [J].
Ongsakul, W .
ELECTRIC POWER SYSTEMS RESEARCH, 1999, 51 (03) :167-173