Illumination and fluorescence collection volumes for fiber optic probes in tissue

被引:23
作者
Tai, Dean C. S.
Hooks, Darren A.
Harvey, John D.
Smaill, Bruce H.
Soeller, Christian
机构
[1] Univ Auckland, Bioengn Inst, Auckland 1001, New Zealand
[2] Univ Auckland, Dept Phys, Auckland 1001, New Zealand
[3] Univ Auckland, Dept Physiol, Auckland 1001, New Zealand
关键词
fluorescence imaging; optical probe; imaging system; collection volume; illumination volume; intramural measurement;
D O I
10.1117/1.2750288
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical fibers can deliver light to, and collect it from, regions deep in tissue. However, reported illumination and fluorescence collection volumes adjacent to the fiber tip have been inconsistent, and systematic data on this topic are not available. Illumination and fluorescence collection profiles were characterized with high spatial resolution for different optical fibers in tissue and various fluids using two-photon flash photolysis and excitation. We confirm that illumination and fluorescence collection volumes for optical fibers are near identical. Collection volume is determined by the core dimensions and numerical aperture (NA) of the fiber and the scattering properties of the medium. For a multimode optical fiber with 100 Am core diam and NA=0.22, 80% of the total fluorescence is collected from a depth of 170 Am in tissue and 465 Am in nonscattering fluid. A semiempirical mathematical description of photon flux adjacent to the fiber tip was also developed and validated. This was used to quantify the extent of temporal blurring associated with propagation of a wavefront of altered fluorescence emission across the region addressed by fiber optic probes. We provide information that will facilitate the design of optical probes for tissue imaging or therapeutic applications. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:12
相关论文
共 36 条
[1]  
Ackroyd R, 2001, PHOTOCHEM PHOTOBIOL, V74, P656, DOI 10.1562/0031-8655(2001)074<0656:THOPAP>2.0.CO
[2]  
2
[3]   Visualizing excitation waves inside cardiac muscle using transillumination [J].
Baxter, WT ;
Mironov, SF ;
Zaitsev, AV ;
Jalife, J ;
Pertsov, AM .
BIOPHYSICAL JOURNAL, 2001, 80 (01) :516-530
[4]   Synthesis of voltage-sensitive optical signals: Application to panoramic optical mapping [J].
Bishop, MJ ;
Rodriguez, B ;
Eason, J ;
Whiteley, JP ;
Trayanova, N ;
Gavaghan, DJ .
BIOPHYSICAL JOURNAL, 2006, 90 (08) :2938-2945
[5]   Development of an optrode for intramural multisite optical recordings of Vm in the heart [J].
Byars, JL ;
Smith, WM ;
Ideker, RE ;
Fast, VG .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (11) :1196-1202
[6]   Intramural measurement of transmembrane potential in the isolated pig heart: Validation of a novel technique [J].
Caldwell, BJ ;
Legrice, IJ ;
Hooks, DA ;
Tai, DCS ;
Pullan, AJ ;
Smaill, BH .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (09) :1001-1010
[7]   Probing microscopic diffusion by 2-photon flash photolysis: Measurement of isotropic and anisotropic diffusion in lens fiber cells [J].
Cannell, MB ;
Jacobs, MD ;
Donaldson, PJ ;
Soeller, C .
MICROSCOPY RESEARCH AND TECHNIQUE, 2004, 63 (01) :50-57
[8]   Metabolism-enhanced tumor localization by fluorescence imaging:: in vivo animal studies [J].
Chen, Y ;
Zheng, G ;
Zhang, ZH ;
Blessington, D ;
Zhang, M ;
Li, H ;
Liu, Q ;
Zhou, L ;
Intes, X ;
Achilefu, S ;
Chance, B .
OPTICS LETTERS, 2003, 28 (21) :2070-2072
[9]   Nonuniform responses of transmembrane potential during electric field stimulation of single cardiac cells [J].
Cheng, DKL ;
Tung, L ;
Sobie, EA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 277 (01) :H351-H362
[10]   A REVIEW OF THE OPTICAL-PROPERTIES OF BIOLOGICAL TISSUES [J].
CHEONG, WF ;
PRAHL, SA ;
WELCH, AJ .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (12) :2166-2185