Mechanical Property Assessment of Bone Healing around a Titanium-Zirconium Alloy Dental Implant

被引:27
作者
Anchieta, Rodolfo B. [1 ,2 ]
Baldassarri, Marta [1 ]
Guastaldi, Fernando [1 ,2 ]
Tovar, Nick [1 ]
Janal, Malvin N. [3 ]
Gottlow, Jan [4 ]
Dard, Michel [5 ]
Jimbo, Ryo [6 ]
Coelho, Paulo G. [1 ,5 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY USA
[2] Sao Paulo State Univ, Aracatuba Dent Sch UNESP, Aracatuba, SP, Brazil
[3] NYU, Coll Dent, Dept Epidemiol, New York, NY USA
[4] Univ Gothenburg, Sahlgrenska Acad, Inst Surg Sci, Dept Biomat, Gothenburg, Sweden
[5] NYU, Coll Dent, Dept Periodontol & Implant Dent, New York, NY USA
[6] Malmo Univ, Fac Odontol, Dept Prosthodont, S-20506 Malmo, Sweden
关键词
animal model; biomechanics; bone; dental; endosteal implants; nanoindentation; TISSUE INTEGRATION; OSSEOINTEGRATION; NANOINDENTATION; PURE;
D O I
10.1111/cid.12061
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundIt has been reported that titanium-zirconium alloy with 13-17% zirconium (TiZr1317) implants show higher biomechanical stability and bone area percentage relative to commercially pure titanium (cpTi) grade 4 fixtures. PurposeThis study aimed to determine whether the higher stability for TiZr1317 implants is associated with higher mechanical properties of remodeling bone in the areas around the implants. Materials and MethodsThis study utilized 36 implants (n=18: TiZr1317, n=18: cpTi), which were placed in the healed ridges of the mandibular premolar and first molar of 12 mini pigs (n=3 implants/animal). After 4 weeks in vivo, the samples were retrieved, and resin-embedded histologic sections of approximately 100m in thickness were prepared. In order to determine the nanomechanical properties, nanoindentation (n=30 tests/specimen) was performed on the bone tissue of the sections under wet conditions with maximum load of 300N (loading rate: 60N/s). ResultsThe mean (standard deviation) elastic modulus (E) and hardness (H) for the TiZr1317 group were 2.73 +/- 0.50GPa and 0.116 +/- 0.017GPa, respectively. For the cpTi group, values were 2.68 +/- 0.51GPa and 0.110 +/- 0.017GPa for E and H, respectively. Although slightly higher mechanical properties values were observed for the TiZr1317 implants relative to the cpTi for both elastic modulus and hardness, these differences were not significant (E=p>0.75; H=p>0.59). ConclusionsThe titanium-zirconium alloy used in this study presented similar degrees of nanomechanical properties to that of the cpTi implants.
引用
收藏
页码:913 / 919
页数:7
相关论文
共 29 条
[1]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]   Mechanical properties of human bone surrounding plateau root form implants retrieved after 0.3-24 years of function [J].
Baldassarri, Marta ;
Bonfante, Estevam A. ;
Suzuki, Marcelo ;
Marin, Charles ;
Granato, Rodrigo ;
Tovar, Nick ;
Coelho, Paulo G. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (07) :2015-2021
[4]  
Balshi T J, 1996, Int J Oral Maxillofac Implants, V11, P660
[5]  
Bernhard N., 2009, FORUM IMPLANTOL, V5, P30
[6]   OSSEOINTEGRATED TITANIUM FIXTURES IN THE TREATMENT OF EDENTULOUSNESS [J].
BRANEMARK, PI ;
ADELL, R ;
ALBREKTSSON, T ;
LEKHOLM, U ;
LUNDKVIST, S ;
ROCKLER, B .
BIOMATERIALS, 1983, 4 (01) :25-28
[7]   The histological evaluation of osseointegration of surface enhanced microimplants immediately loaded in conjunction with sinuslifting in humans [J].
Browaeys, Hilde ;
Vandeweghe, Stefan ;
Johansson, Carina B. ;
Jimbo, Ryo ;
Deschepper, Ellen ;
De Bruyn, Hugo .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (01) :36-44
[8]   Harder and stiffer bone Osseointegrated to roughened titanium [J].
Butz, F. ;
Aita, H. ;
Wang, C. J. ;
Ogawa, T. .
JOURNAL OF DENTAL RESEARCH, 2006, 85 (06) :560-565
[9]   A method for interpreting the data from depth-sensing indentation instruments [J].
Doerner, M. F. ;
Nix, W. D. .
JOURNAL OF MATERIALS RESEARCH, 1986, 1 (04) :601-609
[10]   Evaluation of a New Titanium-Zirconium Dental Implant: A Biomechanical and Histological Comparative Study in the Mini Pig [J].
Gottlow, Jan ;
Dard, Michel ;
Kjellson, Fred ;
Obrecht, Marcel ;
Sennerby, Lars .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (04) :538-545