Assessment of automated cone-beam CT vessel identification software during transarterial hepatic embolisation: radiation dose, contrast medium volume, processing time, and operator perspectives compared to digital subtraction angiography

被引:11
作者
Durack, J. C. [1 ]
Brown, K. T. [1 ]
Avignon, G. [2 ]
Brody, L. A. [1 ]
Sofocleous, C. T. [1 ]
Erinjeri, J. P. [1 ]
Solomon, S. B. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, Intervent Radiol Serv, New York, NY 10065 USA
[2] GE Healthcare, 283 Rue Miniere, F-78533 Buc, France
关键词
TRANSCATHETER ARTERIAL CHEMOEMBOLIZATION; SMALL HEPATOCELLULAR-CARCINOMA; FEEDER DETECTION SOFTWARE; TUMOR-FEEDING VESSELS; COMPUTED-TOMOGRAPHY; ARM CT; DETECTABILITY; TECHNOLOGY;
D O I
10.1016/j.crad.2018.08.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate arterial cone-beam computed tomography (A-CBCT) automated analysis software for identification of vessels supplying tumours during transarterial hepatic embolisation (TAE). MATERIALS AND METHODS: This study was approved by the institutional review board, with waiver of consent. Consecutive TAE procedures using arterial mapping software (AMS), and performed between February 2014 and August 2014, were reviewed. Hepatic arteries were imaged using digital subtraction angiography (DSA) as well as A-CBCT processed with AMS. Interventional radiologists reported potential embolisation target vessels computed using AMS versus DSA alone,(2) modification of the embolisation plan based on AMS, and(3) operator confidence related to technical success. Imaging set-up, processing time, radiation dose, and contrast media volume were recorded. RESULTS: Thirty of 34 consecutive procedures were evaluated retrospectively. At least one additional embolisation target vessel was identified using AMS in 13 procedures (43%, 95% confidence interval [CI]: 26-61%) and embolisation plan modified in 11 (37%, 95% CI: 19-54%). Radiologists reported AMS increased operator confidence and reduced the number of DSA acquisitions in 25 (83%, 95% CI: 70-97%) and 15 cases (50%, 95% CI: 32-68%), respectively. The average A-CBCT acquisition and processing time was 4 minutes 53 seconds and 3 minutes 45 seconds, respectively. A-CBCT contributed to 11% of the radiation dose and 18% of the contrast media volume. CONCLUSION: Physicians report increased tumour supplying vessel detection and intraprocedural confidence using AMS during TAE without substantial impact on radiation dose, contrast media volume, and procedure time. (C) 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1057.e1 / 1057.e6
页数:6
相关论文
共 21 条
[1]   Society of Interventional Radiology Position Statement on Chemoembolization of Hepatic Malignancies (Reprinted from J Vasc Interv Radiol vol 17, pg 217-223, 2006) [J].
Brown, Daniel B. ;
Geschwind, Jean-Francois H. ;
Soulen, Michael C. ;
Millward, Steven F. ;
Sacks, David .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (07) :S317-S323
[2]   Randomized Trial of Hepatic Artery Embolization for Hepatocellular Carcinoma Using Doxorubicin-Eluting Microspheres Compared With Embolization With Microspheres Alone [J].
Brown, Karen T. ;
Do, Richard K. ;
Gonen, Mithat ;
Covey, Anne M. ;
Getrajdman, George I. ;
Sofocleous, Constantinos T. ;
Jarnagin, William R. ;
D'Angelica, Michael I. ;
Allen, Peter J. ;
Erinjeri, Joseph P. ;
Brody, Lynn A. ;
O'Neill, Gerald P. ;
Johnson, Kristian N. ;
Garcia, Alessandra R. ;
Beattie, Christopher ;
Zhao, Binsheng ;
Solomon, Stephen B. ;
Schwartz, Lawrence H. ;
DeMatteo, Ronald ;
Abou-Alfa, Ghassan K. .
JOURNAL OF CLINICAL ONCOLOGY, 2016, 34 (17) :2046-+
[3]   Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study [J].
Deschamps, Frederic ;
Solomon, Stephen B. ;
Thronton, Raymond H. ;
Rao, Pramod ;
Hakime, Antoine ;
Kuoch, Viseth ;
de Baere, Thierry .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (06) :1235-1242
[4]  
Itsubo M, 2002, HEPATO-GASTROENTEROL, V49, P735
[5]   Accuracy of software-assisted detection of tumour feeders in transcatheter hepatic chemoembolization using three target definition protocols [J].
Iwazawa, J. ;
Ohue, S. ;
Hashimoto, N. ;
Mitani, T. .
CLINICAL RADIOLOGY, 2014, 69 (02) :145-150
[6]   Comparison of the Number of Image Acquisitions and Procedural Time Required for Transarterial Chemoembolization of Hepatocellular Carcinoma with and without Tumor-Feeder Detection Software [J].
Iwazawa, Jin ;
Ohue, Shoichi ;
Hashimoto, Naoko ;
Mitani, Takashi .
RADIOLOGY RESEARCH AND PRACTICE, 2013, 2013
[7]   Clinical utility and limitations of tumor-feeder detection software for liver cancer embolization [J].
Iwazawa, Jin ;
Ohue, Shoichi ;
Hashimoto, Naoko ;
Muramoto, Osamu ;
Mitani, Takashi .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (10) :1665-1671
[8]   Survival after C-arm CT-assisted chemoembolization of unresectable hepatocellular carcinoma [J].
Iwazawa, Jin ;
Ohue, Shoichi ;
Hashimoto, Naoko ;
Muramoto, Osamu ;
Mitani, Takashi .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) :3985-3992
[9]   Comparing the Detectability of Hepatocellular Carcinoma by C-Arm Dual-Phase Cone-Beam Computed Tomography During Hepatic Arteriography With Conventional Contrast-Enhanced Magnetic Resonance Imaging [J].
Loffroy, Romaric ;
Lin, MingDe ;
Rao, Pramod ;
Bhagat, Nikhil ;
Noordhoek, Niels ;
Radaelli, Alessandro ;
Blijd, Jarl ;
Geschwind, Jean-Francois .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (01) :97-104
[10]   SMALL HEPATOCELLULAR-CARCINOMA - TREATMENT WITH SUBSEGMENTAL TRANSCATHETER ARTERIAL EMBOLIZATION [J].
MATSUI, O ;
KADOYA, M ;
YOSHIKAWA, J ;
GABATA, T ;
ARAI, K ;
DEMACHI, H ;
MIYAYAMA, S ;
TAKASHIMA, T ;
UNOURA, M ;
KOGAYASHI, K .
RADIOLOGY, 1993, 188 (01) :79-83