Test-retest reliability of the 5-minute psychomotor vigilance task in working-aged females

被引:5
|
作者
Thompson, Brennan J. [1 ,2 ]
Shugart, Caroline [1 ,2 ]
Dennison, Katharine [1 ,2 ]
Louder, Talin J. [1 ,2 ]
机构
[1] Utah State Univ, Kinesiol & Hlth Sci Dept, Logan, UT 84322 USA
[2] Utah State Univ, Sorenson Legacy Fdn, Movement Res Clin, Ctr Clin Excellence, Logan, UT 84322 USA
关键词
PVT; Neurocognitive assessment; Fatigue; Neurobehavioral alertness; Occupational fatigue; SLEEP; PVT; PERFORMANCE; VALIDITY;
D O I
10.1016/j.jneumeth.2021.109379
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: The psychomotor vigilance task (PVT) is a commonly used test that effectively assesses neurobehavioral alertness. The originally developed PVT is 10 minutes in duration, which presents practical and logistical issues, particularly when administered to large samples or on a repetitive basis. More recently the PVT has been used in both 3- and 5-minute formats. While both of these durations have been shown to be field sensitive to identify impairments from sleep- and fatigue-related interventions, the 5-minute version has been suggested to be more valid than the 3-minute. However, while these have shown field-validity in a number of working populations, there is a paucity of data reporting the test-retest reliability statistics of the 5-minute PVT, particularly in working-aged females. The purpose of the study was to examine the test-retest reliability of a comprehensive set of PVT variables for the 5-minute PVT in a population of working-aged females (20-63 years). New method: Participants reported to the laboratory on two separate days and performed a 5-minute PVT on each occasion. Outcome measures included the mean reaction time (MRT), fastest and slowest 10% of reaction times (F10RT% and S10RT%, respectively), standard deviation of reaction times (SDRT) as well as error-based metrics including major and minor lapses, anticipations, and false starts. In addition, total errors (ERR) were computed as a composite of all types of errors. Reliability statistics were reported as intraclass correlation coefficients (ICCs), standard error of measurement (SEM, SEM%), and minimal difference to be considered real (MD, MD%). Systematic error was also evaluated between sessions. Results: Overall high reliability was shown for the MRT (ICC = 0.79, SEM% = 4.14%) and F10RT% (ICC = 0.83, SEM% = 4.43%) variables, with moderate relative reliability (based on ICCs) for the false starts, ERR, and sleepiness scale (ICC = 0.50 - 0.70) variables but these all exhibited poor absolute reliability (based on SEM% values of 32.60 - 168.69%). Poor relative reliability was found for the SDRT and S10RT% variables (ICCs < 0.50) but the S10RT% variable had good absolute reliability (SEM% = 7.12%). The minor and major lapses and anticipations variables had too few of event occurrences for a confident determination of the reliability. Conclusions: The finding that the MRT variable displayed systematic error (P = 0.01) indicating that a learning curve may have been present, but the F10RT% did not show systematic error, suggests the F10RT% may be the most reliable PVT variable in a 5-minute duration test. These findings provide researchers and practitioners with reliability statistics that may help in determining which variable(s) to use, and which to avoid when specifically conducting 5-minute PVT assessments, particularly in a population of working-aged females. These results suggest that the 5-minute PVT can be used in place of the 10-minute version, if used appropriately.
引用
收藏
页数:5
相关论文
共 48 条
  • [1] Reliability of the 5-min psychomotor vigilance task in a primary school classroom setting
    Wilson, Andrew
    Dollman, James
    Lushington, Kurt
    Olds, Timothy
    BEHAVIOR RESEARCH METHODS, 2010, 42 (03) : 754 - 758
  • [2] Test-Retest Reliability of the 6-Minute Walk Test in Individuals With Down Syndrome
    Casey, Amanda F.
    Wang, Xu
    Osterling, Kristin
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11): : 2068 - 2074
  • [3] Recovery of reliability by retest after a 5-minute interval in frequency doubling technology perimetry
    Tsukamoto, Hidetoshi
    Mukai, Satoshi
    Iwase, Aiko
    Mishima, Hiromu K.
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2006, 50 (04) : 380 - 382
  • [4] Recovery of Reliability by Retest After a 5-Minute Interval in Frequency Doubling Technology Perimetry
    Hidetoshi Tsukamoto
    Satoshi Mukai
    Aiko Iwase
    Hiromu K Mishima
    Japanese Journal of Ophthalmology, 2006, 50 : 380 - 382
  • [5] Test-retest reliability of the play-or-pass version of the Iowa Gambling Task
    Haynes, Jeremy M.
    Haines, Nathaniel
    Sullivan-Toole, Holly
    Olino, Thomas M.
    COGNITIVE AFFECTIVE & BEHAVIORAL NEUROSCIENCE, 2024, 24 (04) : 740 - 754
  • [6] Test-Retest Reliability of the Tower of London Planning Task (TOL-F)
    Koestering, Lena
    Nitschke, Kai
    Schumacher, F. Konrad
    Weiller, Cornelius
    Kaller, Christoph P.
    PSYCHOLOGICAL ASSESSMENT, 2015, 27 (03) : 925 - 931
  • [7] Test-retest reliability of prepulse inhibition (PPI) and PPI correlation with working memory
    Freudenberg, Florian
    Althen, Heike
    Falk, Kim
    Bittner, Robert A.
    Reif, Andreas
    Plichta, Michael M.
    ACTA NEUROPSYCHIATRICA, 2022, 34 (06) : 344 - 353
  • [8] Test-retest reliability and construct validity of the Pro-Environmental Behavior Task
    Lange, Florian
    Dewitte, Siegfried
    JOURNAL OF ENVIRONMENTAL PSYCHOLOGY, 2021, 73
  • [9] Test-retest reliability of kinematic and kinetic parameters during dual-task stair walking in the elderly
    Li, Yue
    Yu, Ning
    Zhang, Cui
    Song, Qipeng
    Wang, Jiangna
    Sun, Wei
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [10] Test-retest reliability of drop jumps in students aged seven and eight: exploratory investigation
    Sortwell, Andrew
    Ramirez-Campillo, Rodrigo
    SPORT SCIENCES FOR HEALTH, 2022, 18 (04) : 1379 - 1385