Reliability of F-Scan in-shoe measurements of plantar pressure

被引:98
|
作者
Ahroni, JH
Boyko, EJ
Forsberg, R
机构
[1] Vet Affairs Puget Sound Hlth Care Syst, Seattle Diabet Foot Study, Gen Internal Med Clin 111 M, Seattle, WA 98108 USA
[2] Univ Washington, Sch Nursing, Dept Biobehav Nursing & Hlth Syst, Seattle, WA 98195 USA
关键词
D O I
10.1177/107110079801901004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Research by our group and others indicates that many amputations of the lower limb occur after foot ulceration in patients with diabetes. It has been proposed that diabetic fool ulcers are mainly caused by repetitive trauma in areas of high plantar pressure during walking. Recent technology permits in-shoe measurement of plantar pressure. We assessed the reliability of the F-Scan in-shoe system for measurement of plantar pressure (Tekscan Inc., Boston, MA) in 51 subjects from a cohort of 977 diabetic veterans enrolled in a prospective study of risk factors for foot ulceration and amputation (the Seattle Diabetic Foot Study). Subjects were tested twice, wearing their own shoes. We used the coefficient of variation (CV) and the intraclass correlation coefficient (ICC) to estimate the reliability of F-Scan measurements of pressure. Peak pressure over the metatarsal heads proved to have the best indices of reliability, with CVs of 0.150 and 0.155, and ICCs of 0.755 and 0.751. Coefficients of variation for the heel, whole foot, and hallux ranged from 0.148 to 0.240, with ICCs ranging from 0.493 to 0.832. By published standards, peak pressures over the metatarsal heads and right hallux met the criteria for excellent reliability. Our ICCs for high pressures under the foot, heel, metatarsal heads, and hallux, and for peak pressures under the heel and left hallux represented fair-to-good reliability. No F-Scan plantar measurements could be judged by these criteria as having poor reliability. This clinical study found that for elderly patients with diabetes who were wearing their own shoes and were tested on two different days with different insoles, the F-Scan insole system was generally reliable for measurements of high pressure and peak pressure.
引用
收藏
页码:668 / 673
页数:6
相关论文
共 50 条
  • [41] Reliability of an in-shoe pressure measurement system during treadmill walking
    Kernozek, TW
    LaMott, EE
    Dancisak, MJ
    FOOT & ANKLE INTERNATIONAL, 1996, 17 (04) : 204 - 209
  • [42] An optimized design of in-shoe heel lifts reduces plantar pressure of healthy males
    Zhang, Xianyi
    Li, Bo
    Liang, Kaiyun
    Wan, Qiufeng
    Vanwanseele, Benedicte
    GAIT & POSTURE, 2016, 47 : 43 - 47
  • [43] Use Of An In-Shoe Pressure Device To Measure Plantar Pressures While Cycling With Orthotics
    Pazan, Steven E.
    Gracey, Chris
    Danoff, Jerome V.
    Paul, Scott
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05): : 558 - 558
  • [44] Can the F-Scan in-shoe pressure system be combined with the GAITRite® temporal and spatial parameter-recording walkway as a cost-effective alternative in clinical gait analysis? A validation study
    Speight, Stephanie
    Reel, Sarah
    Stephenson, John
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2023, 16 (01)
  • [45] Can the F-Scan in-shoe pressure system be combined with the GAITRite® temporal and spatial parameter-recording walkway as a cost-effective alternative in clinical gait analysis? A validation study
    Stephanie Speight
    Sarah Reel
    John Stephenson
    Journal of Foot and Ankle Research, 16
  • [46] A PORTABLE IN-SHOE PRESSURE MONITOR
    LEVIN, MR
    REINECK, KM
    HESSELINK, J
    VAUGHAN, CL
    JOURNAL OF BIOMECHANICS, 1986, 19 (06) : 475 - 475
  • [47] Integrated 3D motion and plantar pressure measurement for in-shoe orthoses evaluation
    Woodburn, J.
    Helliwell, P.
    Clinical Biomechanics, 1999, 14 (08):
  • [48] Observations of In-shoe plantar pressures in patients with rheumatoid arthritis
    Bowen, C. J.
    Backhouse, M.
    Burridge, J.
    Arden, N. K.
    RHEUMATOLOGY, 2007, 46 : I155 - I155
  • [49] Evaluation of in-shoe plantar pressure and shear during walking for diabetic foot ulcer prevention
    Tang, Jinghua
    Bader, Dan L.
    Parker, Daniel J.
    Forghany, Saeed
    Nester, Christopher J.
    Moser, David
    Jiang, Liudi
    JOURNAL OF WOUND CARE, 2023, 32 (09) : 587 - 596
  • [50] An anatomically-based masking protocol for the assessment of in-shoe plantar pressure measurement of the forefoot
    Saeed Forghany
    Daniel R. Bonanno
    Hylton B. Menz
    Karl B. Landorf
    Journal of Foot and Ankle Research, 11