Reliability of F-Scan in-shoe measurements of plantar pressure

被引:98
|
作者
Ahroni, JH
Boyko, EJ
Forsberg, R
机构
[1] Vet Affairs Puget Sound Hlth Care Syst, Seattle Diabet Foot Study, Gen Internal Med Clin 111 M, Seattle, WA 98108 USA
[2] Univ Washington, Sch Nursing, Dept Biobehav Nursing & Hlth Syst, Seattle, WA 98195 USA
关键词
D O I
10.1177/107110079801901004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Research by our group and others indicates that many amputations of the lower limb occur after foot ulceration in patients with diabetes. It has been proposed that diabetic fool ulcers are mainly caused by repetitive trauma in areas of high plantar pressure during walking. Recent technology permits in-shoe measurement of plantar pressure. We assessed the reliability of the F-Scan in-shoe system for measurement of plantar pressure (Tekscan Inc., Boston, MA) in 51 subjects from a cohort of 977 diabetic veterans enrolled in a prospective study of risk factors for foot ulceration and amputation (the Seattle Diabetic Foot Study). Subjects were tested twice, wearing their own shoes. We used the coefficient of variation (CV) and the intraclass correlation coefficient (ICC) to estimate the reliability of F-Scan measurements of pressure. Peak pressure over the metatarsal heads proved to have the best indices of reliability, with CVs of 0.150 and 0.155, and ICCs of 0.755 and 0.751. Coefficients of variation for the heel, whole foot, and hallux ranged from 0.148 to 0.240, with ICCs ranging from 0.493 to 0.832. By published standards, peak pressures over the metatarsal heads and right hallux met the criteria for excellent reliability. Our ICCs for high pressures under the foot, heel, metatarsal heads, and hallux, and for peak pressures under the heel and left hallux represented fair-to-good reliability. No F-Scan plantar measurements could be judged by these criteria as having poor reliability. This clinical study found that for elderly patients with diabetes who were wearing their own shoes and were tested on two different days with different insoles, the F-Scan insole system was generally reliable for measurements of high pressure and peak pressure.
引用
收藏
页码:668 / 673
页数:6
相关论文
共 50 条
  • [31] In-Shoe Plantar Pressure Measurement and Analysis System Based on Fabric Pressure Sensing Array
    Shu, Lin
    Hua, Tao
    Wang, Yangyong
    Li, Qiao
    Feng, David Dagan
    Tao, Xiaoming
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (03): : 767 - 775
  • [32] Development of Self-Calibrating Sensor Footwear and Relevance of In-Shoe Characterization on Accurate Plantar Pressure Distribution Measurements
    Martinez-Barba, Daniel A.
    Martinez-Manuel, Rodolfo
    Daza-Benitez, Leonel
    Vidal-Lesso, Agustin
    IEEE SENSORS JOURNAL, 2021, 21 (06) : 8421 - 8431
  • [33] IN-SHOE PLANTAR PRESSURE MEASUREMENTS FOR THE EVALUATION AND ADAPTATION OF FOOT ORTHOSES IN PATIENTS WITH RHEUMATOID ARTHRITIS: A PROOF OF CONCEPT STUDY
    Tenten-Diepenmaat, M.
    Dekker, J.
    Steenbergen, M.
    Huybrechts, E.
    Roorda, L.
    van Schaardenburg, D.
    Bus, S.
    van der Leeden, M.
    ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 : 1354 - 1355
  • [34] In-shoe plantar pressure measurements for the evaluation and adaptation of foot orthoses in patients with rheumatoid arthritis: A proof of concept study
    Tenten-Diepenmaat, Marloes
    Dekker, Joost
    Steenbergen, Menno
    Huybrechts, Elleke
    Roorda, Leo D.
    van Schaardenburg, Dirkjan
    Bus, Sicco A.
    van der Leeden, Marike
    GAIT & POSTURE, 2016, 45 : 45 - 50
  • [35] The effects of off-the-shelf in-shoe heel inserts on forefoot plantar pressure
    Ramanathan, A. K.
    John, M. C.
    Arnold, G. P.
    Cochrane, L.
    Abboud, R. J.
    GAIT & POSTURE, 2008, 28 (04) : 533 - 537
  • [36] In-shoe Plantar Pressure Distribution in Nonneuropathic Type 2 Diabetic Patients in Singapore
    Tong, Jasper W. K.
    Acharya, U. Rajendra
    Chua, Kuang C.
    Tan, Peck H.
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2011, 101 (06) : 509 - 516
  • [37] Daily-life activities and in-shoe forefoot plantar pressure in patients with diabetes
    Guldemond, Nick A.
    Leffers, Pieter
    Sanders, Antal P.
    Schaper, Nicolaas C.
    Nieman, Fred
    Walenkamp, Geert H. I. M.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2007, 77 (02) : 203 - 209
  • [38] Comparison of in-shoe plantar pressure between Korean combat boots and running shoes
    Yoon, Young Sik
    An, D. H.
    Lee, Y. J.
    Lee, D. Y.
    Kyung, M. G.
    BMJ MILITARY HEALTH, 2024,
  • [39] Bare Foot and In-shoe Plantar Pressure in Diabetic Males and Females-Is There Difference?
    Altayyar, Saleh S.
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2021, 14 : 271 - 276
  • [40] IN-SHOE PLANTAR MEASUREMENT WITH TEKSCAN SENSOR SYSTEM
    KOCH, M
    BIOMEDIZINISCHE TECHNIK, 1993, 38 (10): : 243 - 248