Reliability of F-Scan in-shoe measurements of plantar pressure

被引:98
|
作者
Ahroni, JH
Boyko, EJ
Forsberg, R
机构
[1] Vet Affairs Puget Sound Hlth Care Syst, Seattle Diabet Foot Study, Gen Internal Med Clin 111 M, Seattle, WA 98108 USA
[2] Univ Washington, Sch Nursing, Dept Biobehav Nursing & Hlth Syst, Seattle, WA 98195 USA
关键词
D O I
10.1177/107110079801901004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Research by our group and others indicates that many amputations of the lower limb occur after foot ulceration in patients with diabetes. It has been proposed that diabetic fool ulcers are mainly caused by repetitive trauma in areas of high plantar pressure during walking. Recent technology permits in-shoe measurement of plantar pressure. We assessed the reliability of the F-Scan in-shoe system for measurement of plantar pressure (Tekscan Inc., Boston, MA) in 51 subjects from a cohort of 977 diabetic veterans enrolled in a prospective study of risk factors for foot ulceration and amputation (the Seattle Diabetic Foot Study). Subjects were tested twice, wearing their own shoes. We used the coefficient of variation (CV) and the intraclass correlation coefficient (ICC) to estimate the reliability of F-Scan measurements of pressure. Peak pressure over the metatarsal heads proved to have the best indices of reliability, with CVs of 0.150 and 0.155, and ICCs of 0.755 and 0.751. Coefficients of variation for the heel, whole foot, and hallux ranged from 0.148 to 0.240, with ICCs ranging from 0.493 to 0.832. By published standards, peak pressures over the metatarsal heads and right hallux met the criteria for excellent reliability. Our ICCs for high pressures under the foot, heel, metatarsal heads, and hallux, and for peak pressures under the heel and left hallux represented fair-to-good reliability. No F-Scan plantar measurements could be judged by these criteria as having poor reliability. This clinical study found that for elderly patients with diabetes who were wearing their own shoes and were tested on two different days with different insoles, the F-Scan insole system was generally reliable for measurements of high pressure and peak pressure.
引用
收藏
页码:668 / 673
页数:6
相关论文
共 50 条
  • [21] In-shoe pressure measurements with a viscoelastic heel orthosis
    Hsi, WL
    Lai, JS
    Yang, PY
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (07): : 805 - 810
  • [22] SENSATE AND INSENSATE IN-SHOE PLANTAR PRESSURES
    ZHU, HS
    WERTSCH, JJ
    HARRIS, GF
    ALBA, HM
    PRICE, MB
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1993, 74 (12): : 1362 - 1368
  • [23] A study of in-shoe plantar shear in normals
    Hosein, R
    Lord, M
    CLINICAL BIOMECHANICS, 2000, 15 (01) : 46 - 53
  • [24] Reliability of the Pedar in-shoe system for plantar pressure measurement in diabetic patients with and without neuropathy: a prospective study
    Forogh, Bijan
    Raissi, Gholam Reza
    Soleymanzadeh, Hosnieh
    Cham, Masumeh Bagherzadeh
    CURRENT ORTHOPAEDIC PRACTICE, 2022, 33 (01): : 56 - 61
  • [25] Software-Defined Design of In-shoe Plantar Pressure Measurement Mechanism
    Lee, Chao-Hsien
    Wu, Hsin-Liang
    2023 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, ICCE, 2023,
  • [26] In-shoe plantar pressure measurement technologies for the diabetic foot: A systematic review
    Castro-Martins, Pedro
    Marques, Arcelina
    Coelho, Luis
    Vaz, Mario
    Baptista, Joao Santos
    HELIYON, 2024, 10 (09)
  • [27] An in-shoe device to measure plantar pressure during daily human activity
    Saito, M.
    Nakajima, K.
    Takano, C.
    Ohta, Y.
    Sugimoto, C.
    Ezoe, R.
    Sasaki, K.
    Hosaka, H.
    Ifukube, T.
    Ino, S.
    Yamashita, K.
    MEDICAL ENGINEERING & PHYSICS, 2011, 33 (05) : 638 - 645
  • [28] The effect of foot type on in-shoe plantar pressure during walking and running
    Chuckpaiwong, Bavornrit
    Nunley, James A.
    Mall, Nathan A.
    Queen, Robin M.
    GAIT & POSTURE, 2008, 28 (03) : 405 - 411
  • [29] Validity and reliability of the XSENSOR in-shoe pressure measurement system
    Parker, Daniel
    Andrews, Jennifer
    Price, Carina
    PLOS ONE, 2023, 18 (01):
  • [30] Surface effects on in-shoe plantar pressure and tibial impact during running
    Fu, Weijie
    Fang, Ying
    Liu, David Ming Shuo
    Wang, Lin
    Ren, Sicong
    Liu, Yu