Reliability of F-Scan in-shoe measurements of plantar pressure

被引:98
|
作者
Ahroni, JH
Boyko, EJ
Forsberg, R
机构
[1] Vet Affairs Puget Sound Hlth Care Syst, Seattle Diabet Foot Study, Gen Internal Med Clin 111 M, Seattle, WA 98108 USA
[2] Univ Washington, Sch Nursing, Dept Biobehav Nursing & Hlth Syst, Seattle, WA 98195 USA
关键词
D O I
10.1177/107110079801901004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Research by our group and others indicates that many amputations of the lower limb occur after foot ulceration in patients with diabetes. It has been proposed that diabetic fool ulcers are mainly caused by repetitive trauma in areas of high plantar pressure during walking. Recent technology permits in-shoe measurement of plantar pressure. We assessed the reliability of the F-Scan in-shoe system for measurement of plantar pressure (Tekscan Inc., Boston, MA) in 51 subjects from a cohort of 977 diabetic veterans enrolled in a prospective study of risk factors for foot ulceration and amputation (the Seattle Diabetic Foot Study). Subjects were tested twice, wearing their own shoes. We used the coefficient of variation (CV) and the intraclass correlation coefficient (ICC) to estimate the reliability of F-Scan measurements of pressure. Peak pressure over the metatarsal heads proved to have the best indices of reliability, with CVs of 0.150 and 0.155, and ICCs of 0.755 and 0.751. Coefficients of variation for the heel, whole foot, and hallux ranged from 0.148 to 0.240, with ICCs ranging from 0.493 to 0.832. By published standards, peak pressures over the metatarsal heads and right hallux met the criteria for excellent reliability. Our ICCs for high pressures under the foot, heel, metatarsal heads, and hallux, and for peak pressures under the heel and left hallux represented fair-to-good reliability. No F-Scan plantar measurements could be judged by these criteria as having poor reliability. This clinical study found that for elderly patients with diabetes who were wearing their own shoes and were tested on two different days with different insoles, the F-Scan insole system was generally reliable for measurements of high pressure and peak pressure.
引用
收藏
页码:668 / 673
页数:6
相关论文
共 50 条
  • [1] Observations on the F-Scan in-shoe pressure measuring system
    Woodburn, J
    Helliwell, PS
    CLINICAL BIOMECHANICS, 1996, 11 (05) : 301 - 304
  • [2] Generalizability of in-shoe peak pressure measures using the F-scan system
    Mueller, MJ
    Strube, MJ
    CLINICAL BIOMECHANICS, 1996, 11 (03) : 159 - 164
  • [3] Detection of gait events using an F-Scan in-shoe pressure measurement system
    Catalfamo, Paola
    Moser, David
    Ghoussayni, Salim
    Ewins, David
    GAIT & POSTURE, 2008, 28 (03) : 420 - 426
  • [4] Quantification of the path of center of pressure (COP) using an F-scan in-shoe transducer
    Han, TR
    Paik, NJ
    Im, MS
    GAIT & POSTURE, 1999, 10 (03) : 248 - 254
  • [5] Reliability of in-shoe plantar pressure measurements in rheumatoid arthritis patients
    Vidmar, Gaj
    Novak, Primoz
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2009, 32 (01) : 36 - 40
  • [6] Test-retest reliability of the Tekscan® F-Scan® 7 in-shoe plantar pressure system during treadmill walking in healthy recreationally active individuals
    Patrick, Kyle
    Donovan, Luke
    SPORTS BIOMECHANICS, 2018, 17 (01) : 83 - 97
  • [7] Intrasession Reliability Of Insole In-shoe Plantar Pressure Measurements In Different Foot Areas
    Koenig, Niklas
    Stoll, Andreas
    Mayer, Frank
    Baur, Heiner
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 941 - 941
  • [8] Wearing the F-Scan mobile in-shoe pressure measurement system alters gait characteristics during running
    Kong, Pui W.
    De Heer, Hendrik
    GAIT & POSTURE, 2009, 29 (01) : 143 - 145
  • [9] Plantar pressure measurements using an in-shoe system and a pressure platform: A comparison
    Chevalier, Thierry Larose
    Hodgins, Helen
    Chockalingam, Nachiappan
    GAIT & POSTURE, 2010, 31 (03) : 397 - 399
  • [10] Sensing stability and dynamic response of the F-Scan in-shoe sensing system: A technical note
    Sumiya, T
    Suzuki, Y
    Kasahara, T
    Ogata, H
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1998, 35 (02): : 192 - 200