Validation of the A&D UM-101 professional hybrid device for office blood pressure measurement according to the International Protocol

被引:30
|
作者
Stergiou, George S. [1 ]
Giovas, Periklis P. [1 ]
Gkinos, Charilaos P. [1 ]
Tzamouranis, Dimitris G. [1 ]
机构
[1] Third Univ, Sotiria Hosp, Dept Med, Hypertens Ctr, GR-11527 Athens, Greece
关键词
accuracy; European Society of Hypertension; hybrid sphygmomanometer; International Protocol; office blood pressure; professional device; validation;
D O I
10.1097/MBP.0b013e3282c9acb0
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective Assessment of the accuracy of the A&D UM-101 mercury-free professional device for auscultatory blood pressure (BP) measurement according to the European Society of Hypertension International Protocol. Further to auscultation, the device has a button to mark readings during deflation. Methods Fifteen adults were included in phase 1 and another 18 in phase 2. Simultaneous BP measurements were taken by two observers (connected mercury sphygmomanometers) four times, sequentially with three measurements using the tested device (two connected tested devices, one used with and the other without the mark button). Results In phase 1, the device produced 44/45/45 measurements within 5/10/15 mmHg, respectively, for systolic BP (SBP) and 39/43/45 for diastolic (DBP). In phase 2.1, 87/97/99 measurements within 5/10/15 mmHg, respectively, for SBP, and 91/97/99 for DBP (using the mark button 65/93/98 for SBP and 76/96/99 for DBP). In phase 2.2, 29 participants had at least two of their SBP differences within 5 mmHg and none had any differences within 5 mmHg, whereas 32 and none, respectively, for DBP (with mark 24/4 participants for SBP; 29/1 for DBP). Mean SBP differences were -1.5 +/- 3.5 mmHg and DBP -1.3 +/- 3.0 (with mark -3.6 +/- 4.2 and -2.8 +/- 3.7). The difference in SBP measured by the tested device with versus without using the mark button was 3.0 +/- 3.3 mmHg (P<0.001) and DBP 1.9 +/- 2.5 mmHg (P<0.001). Conclusion The device comfortably passed the validation protocol requirements. Using the mark button, the device, however, failed to meet the validation criteria. Therefore, it is recommended for clinical use without using the mark button.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [31] Validation of the Omron 637IT wrist blood pressure measuring device with a position sensor according to the International Protocol in the elderly
    Altunkan, S
    Altunkan, E
    BLOOD PRESSURE MONITORING, 2006, 11 (02) : 97 - 102
  • [32] Validation of the iHealth BP7 wrist blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010
    Wang, Qing
    Zhao, Huadong
    Chen, Wan
    Li, Ni
    Wan, Yi
    BLOOD PRESSURE MONITORING, 2014, 19 (01) : 54 - 57
  • [33] Validation of A&D TM-2430 upper-arm blood pressure monitor for ambulatory blood pressure monitoring in children and adolescents, according to the British Hypertension Society protocol
    Yip, Gabriel Wai-Kwok
    So, Hung-Kwan
    Li, Albert Martin
    Tomlinson, Brian
    Wong, Sik-Nin
    Sung, Rita Yn-Tz
    BLOOD PRESSURE MONITORING, 2012, 17 (02) : 76 - 79
  • [34] Validation of the A&D wrist-cuff UB-511 (UB-512) device for self-measurement of blood pressure
    Angeli, Fabio
    Sardone, Mariagrazia
    Angeli, Enrica
    Repaci, Salvatore
    Gattobigio, Roberto
    Verdecchia, Paolo
    BLOOD PRESSURE MONITORING, 2006, 11 (06) : 349 - 354
  • [35] Validation of the Andon KD-391 semiautomated blood pressure monitor in adults according to the International Protocol
    Wan, Yi
    Pan, Feng
    Liu, Ya
    Liang, Ying
    Yang, Zhe
    Zhao, Huadong
    Xu, Yongyong
    BLOOD PRESSURE MONITORING, 2009, 14 (04) : 181 - 184
  • [36] Simultaneous validation of the SunTech 247 diagnostic station blood pressure measurement device according to the British Hypertension Society protocol, the International Protocol and the Association for the Advancement of Medical Instrumentation standards
    Friz, Hernan Polo
    Facchetti, Rita
    Primitz, Laura
    Beltrame, Luca
    Galbiati, Valentina
    Ricioppo, Aristodemo
    Bombelli, Michele
    Sega, Roberto
    BLOOD PRESSURE MONITORING, 2009, 14 (05) : 222 - 227
  • [37] Validation of Panasonic EW3106 and EW3109 devices for blood pressure measurement according to the International Protocol
    Bonso, Elisa
    Dorigatti, Francesca
    Palatini, Paolo
    BLOOD PRESSURE MONITORING, 2010, 15 (01) : 55 - 58
  • [38] Validation of the Andon KD-575 automated blood pressure monitor according to the European Society of Hypertension International Protocol in adults
    Pan, Feng
    Wan, Yi
    Chen, Wan
    Li, Ni
    Tong, Wei
    Xu, Yongyong
    BLOOD PRESSURE MONITORING, 2010, 15 (03) : 167 - 170
  • [39] Accuracy of the visomat handy wrist blood pressure measuring device according to the International Protocol
    Saladini, Francesca
    Benetti, Elisabetta
    Palatini, Paolo
    BLOOD PRESSURE MONITORING, 2010, 15 (05) : 281 - 284
  • [40] 'Legacy publication of a 2009 validation of the Riester Big Ben Square Desk aneroid device for blood pressure measurement according to the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults (2002)'
    McNally, Ryan J.
    Dunkerley, Janette
    Holland, Maureen
    Eatough, Ruth
    Lacy, Peter
    McManus, Richard J.
    Chapman, Neil
    Chowienczyk, Philip J.
    Lewis, Philip
    Clark, Christopher E.
    Denver, Elizabeth
    Neary, Annette
    McDonagh, Sinead T. J.
    Sheppard, James P.
    BLOOD PRESSURE MONITORING, 2024, 29 (04) : 203 - 206