Rapid motion correction in MR-guided high-intensity focused ultrasound heating using real-time ultrasound echo information

被引:28
作者
de Oliveira, Philippe Lourenco [1 ]
de Senneville, Baudouin Denis [1 ]
Dragonu, Lulius [1 ]
Moonen, Chrit T. W. [1 ]
机构
[1] Univ Bordeaux 2, CNRS, UMR 5231, Lab Mol & Funct Imaging Physiol Therapy, F-33076 Bordeaux, France
关键词
motion correction; real time; MRI; ultrasound echo; PERFORMANCE; SURGERY;
D O I
10.1002/nbm.1526
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The objective of this study was to evaluate the feasibility of integrating real time ultrasound echo guidance in MR-guided high-intensity focused ultrasound (HIFU) heating of mobile targets in order to reduce latency between displacement analysis and HIFU treatment Experiments on a moving phantom were carried out with MRI-guided HIFU during continuous one-dimensional ultrasound echo detection using separate HIFU and ultrasound imaging transducers Excellent correspondence was found between MR- and ultrasound-detected displacements Real-time ultrasound echo-based target tracking during MR-guided HIFU heating is shown with the dimensions of the heated area similar to those obtained for a static target This work demonstrates that the combination of the two modalities opens up perspectives for motion correction in MRI-guided HIFU with negligible latency Copyright (C) 2010 John Wiley & Sons, Ltd
引用
收藏
页码:1103 / 1108
页数:6
相关论文
共 19 条
[1]  
[Anonymous], 2008, NVIDIA CUDA C Programming Guide, P1
[2]   PERFORMANCE OF OPTICAL-FLOW TECHNIQUES [J].
BARRON, JL ;
FLEET, DJ ;
BEAUCHEMIN, SS .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1994, 12 (01) :43-77
[3]  
CHAMPENEY DC, 1973, CONVOLUTION CORRELAT, P68
[4]   Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound [J].
de Senneville, Baudouin Denis ;
Mougenot, Charles ;
Moonen, Chrit T. W. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (02) :319-330
[5]  
de Zwart JA, 2001, MAGNET RESON MED, V45, P128, DOI 10.1002/1522-2594(200101)45:1<128::AID-MRM1017>3.0.CO
[6]  
2-M
[7]   Real-Time Geometric Distortion Correction for Interventional Imaging with Echo-Planar Imaging (EPI) [J].
Dragonu, Iulius ;
de Senneville, Baudouin Denis ;
Quesson, Bruno ;
Moonen, Chrit ;
Ries, Mario .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (04) :994-1000
[8]  
Friston KJ., 1995, HUM BRAIN MAP, V2, P1
[9]   Magnetic resonance-guided focused ultrasound surgery of breast cancer: Reliability and effectiveness [J].
Furusawa, H ;
Namba, K ;
Thomsen, S ;
Akiyama, F ;
Bendet, A ;
Tanaka, C ;
Yasuda, Y ;
Nakahara, H .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2006, 203 (01) :54-63
[10]   A theoretical assessment of the relative performance of spherical phased arrays for ultrasound surgery [J].
Gavrilov, LR ;
Hand, JW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :125-139