Electrochemical detection of cortisol on graphene quantum dots modified electrodes using a rationally truncated high affinity aptamer

被引:13
作者
Sharma, Vipasha [1 ,2 ]
Sharma, Tarun Kumar [3 ]
Kaur, Inderpreet [1 ,2 ]
机构
[1] CSIR Cent Sci Instruments Org, Biomol Elect & Nanotechnol Grp, Sect 30-C, Chandigarh 160030, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
[3] Translat Hlth Sci & Technol Inst THSTI, Multidisciplinary Clin & Translat Res Grp, Aptamer Technol & Diagnost Lab, Faridabad 12100, Haryana, India
关键词
Stress; Cortisol; Aptamer; Graphene quantum dots; RAPID DETECTION; BIOSENSOR; STRESS; BLUE; NANOMATERIALS; MOLECULES;
D O I
10.1007/s13204-021-02086-x
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Stress nowadays is one of the major causes of various pathologies in humans. Monitoring of stress associated biomarker levels in biological fluids on demand can help in effective management of stress. Since cortisol has been recognised as a potential biomarker for stress, its detection can help in an appropriate therapeutic intervention or stress management. Various types of biosensors such as immunosensors, aptasensors, molecularly imprinted polymers and enzyme-linked based biosensors have been reported till now for the cortisol sensing. Out of all, aptasensors have shown various advantages over other sensors such as specificity, high room temperature stability, reproducibility, etc. Among various reported aptasensors, full-length aptamer (> 60-mer) has been used. However, only a portion of aptamer interact with its target, therefore, establishing its structure-activity relationship is vital for a biosensor to achieve an optimized performance. In the current work, we have rationally truncated already existing 61-mer aptamer sequence into its smaller variant with only 14 bases. Parent and truncated aptamers were immobilized on the graphene quantum dots modified electrodes for electrochemical biosensing of cortisol. Detection limits and cross-reactivities of both the aptamers were compared and it was found that truncated aptamer showed better results in terms of specificity. Though the limit of detection is same for both parent and truncated aptamers, i.e. 0.1 pg/ml but cross-reactivity from various structural analogues in sensing is reduced drastically in case of truncated variant. In brief, we are reporting a label-free electrochemical aptasensor utilizing the truncated aptamer (14-mer) that has remarkable limit of detection (0.1 pg/ml), high level of selectivity and reproducibility for the direct analysis of the cortisol.
引用
收藏
页码:2577 / 2588
页数:12
相关论文
共 50 条
  • [31] A Highly Sensitive Cefotaxime Electrochemical Detection Technique Based on Graphene Quantum Dots
    Duan, Mengting
    He, Xiaowen
    Zhang, Qiu
    Zheng, Bingxin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (07):
  • [32] The beneficial impact of MXene on the electrochemical performance of graphene quantum dots for dopamine detection
    Facure, Murilo H. M.
    Sampaio, Bruno S.
    Mercante, Luiza A.
    Correa, Daniel S.
    MATERIALS TODAY COMMUNICATIONS, 2025, 42
  • [33] A fluorometric sandwich biosensor based on rationally imprinted magnetic particles and aptamer modified carbon dots for the detection of tropomyosin in seafood products
    Wang, Yanbo
    Li, Linfang
    Li, Huan
    Peng, Yafei
    Fu, Linglin
    FOOD CONTROL, 2022, 132
  • [34] A fluorescent sandwich assay for thrombin using aptamer modified magnetic beads and quantum dots
    Xiaofang Wang
    Qiang Zhao
    Microchimica Acta, 2012, 178 : 349 - 355
  • [35] Highly Sensitive and Selective Detection of Cortisol Using a Novel SPR-Aptamer Sensor Modified by Gold Nanoparticles
    Ding, Liyun
    Wei, Shenghu
    Wu, Tian
    Zhang, Yumei
    Ma, Fei
    Zhao, Jue
    Jiang, Xingdong
    Zuo, Juanjuan
    IEEE SENSORS JOURNAL, 2024, 24 (04) : 4199 - 4204
  • [36] Aptamer modified magnetic nanoparticles coupled with fluorescent quantum dots for efficient separation and detection of Alicyclobacillus acidoterrestris in fruit juices
    Tian, Yu
    Li, Xueke
    Cai, Rui
    Yang, Kang
    Gao, ZhenPeng
    Yuan, Yahong
    Yue, Tianli
    Wang, Zhouli
    FOOD CONTROL, 2021, 126
  • [37] Recognition and detection of histamine in foods using aptamer modified fluorescence polymer dots sensors
    Wu, Gan
    Ding, Zhaoyang
    Dou, Xilin
    Chen, Ze
    Xie, Jing
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 317
  • [38] Fentogram electrochemical detection of HIV RNA based on graphene quantum dots and gold nanoparticles
    Moco, Anna C. R.
    Gomide, Jose A. L.
    Flauzino, Jose M. R.
    Brussasco, Jessica G.
    Luz, Luiz F. G.
    Soares, Marcia M. C. N.
    Madurro, Joao M.
    Brito-Madurro, Ana G.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 242
  • [39] Novel electrochemical sensor based on graphene quantum dots/riboflavin nanocomposite for the detection of persulfate
    Roushani, Mahmoud
    Abdi, Zeinab
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 201 : 503 - 510
  • [40] A fluorescent nanosensor based on graphene quantum dots-aptamer probe and graphene oxide platform for detection of lead (II) ion
    Qian, Zhao Sheng
    Shan, Xiao Yue
    Chai, Lu Jing
    Chen, Jian Rong
    Peng, Hui
    BIOSENSORS & BIOELECTRONICS, 2015, 68 : 225 - 231