Real-time chemical analysis of root filling materials with heating: guidelines for safe temperature levels

被引:28
作者
Atmeh, A. R. [1 ]
Hadis, M. [2 ]
Camilleri, J. [2 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, POB 1982, Dammam 31441, Saudi Arabia
[2] Univ Birmingham, Inst Clin Sci, Coll Med & Dent Sci, Sch Dent, Birmingham, W Midlands, England
关键词
calcium silicate; endodontic heat carriers; epoxy resin sealer; gutta-percha; Raman spectroscopy; warm obturation; GUTTA-PERCHA; THERMOMECHANICAL PROPERTIES; VIBRATIONAL DYNAMICS; NATURAL-RUBBER; DEGRADATION; COMPACTION; SPECTROSCOPY; STABILITY; DENSITY; SEALERS;
D O I
10.1111/iej.13269
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To investigate the chemical changes affecting different types of gutta-percha and endodontic sealers during heating, and correlate changes with the heating capacity of different heat carriers. Methodology The heating capacity of three endodontic heat carriers was evaluated using thermocouples to produce heat profiles. The devices were activated at different temperature set-ups, in continuous or cut-out modes. Chemical changes of six brands of gutta-percha and four types of sealers were assessed in real time during heating using micro-Raman spectroscopy equipped with a heating stage. Raman spectra of each tested material were averaged and compared at different temperature levels. The sealers were further assessed by Fourier transform infrared (FT-IR) spectroscopy. Results None of the tested heat carriers achieved the temperature levels that were set by the devices and recommended by the manufacturer. The use of continuous heating mode resulted in higher rises in temperature than the 4 s cut-out mode that reached 110 degrees C. The various brands of gutta-percha exhibited different chemical changes in response to heat. Some changes even occurred below temperature levels generated by the heating devices. All sealers revealed changes in their chemical composition upon heating. Changes in epoxy resin- and zinc oxide-eugenol-based sealers were detectable at 100 degrees C, with structural alterations beyond that temperature and irreversible changes after cooling. Water loss was irreversible in BioRoot, but its chemical structure was stable as well as for the TotalFill. Conclusions The heating capacity of endodontic heat carriers needs to be standardized, so that the temperatures delivered by the tips are the same as that set on the dial. Practitioners should be aware of the actual temperatures generated by these devices, and the suitability of sealers to be used at the temperature levels achieved.
引用
收藏
页码:698 / 708
页数:11
相关论文
共 41 条
  • [1] Fourier transform infrared and Raman spectral analysis of trans-1,4-polyisoprene
    Arjunan, V
    Subramanian, S
    Mohan, S
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2001, 57 (13) : 2547 - 2554
  • [2] The Effect of Heating Time and Temperature on Epoxy Resin and Calcium Silicate-based Endodontic Sealers
    Atmeh, Amre R.
    AlShwaimi, Emad
    [J]. JOURNAL OF ENDODONTICS, 2017, 43 (12) : 2112 - 2118
  • [3] Sealers and Warm Gutta-percha Obturation Techniques
    Camilleri, Josette
    [J]. JOURNAL OF ENDODONTICS, 2015, 41 (01) : 72 - 78
  • [4] Infrared and Raman Spectroscopy of Eugenol, Isoeugenol, and Methyl Eugenol: Conformational Analysis and Vibrational Assignments from Density Functional Theory Calculations of the Anharmonic Fundamentals
    Chowdhry, Babur Z.
    Ryall, John P.
    Dines, Trevor J.
    Mendham, Andrew P.
    [J]. JOURNAL OF PHYSICAL CHEMISTRY A, 2015, 119 (46) : 11280 - 11292
  • [5] SETTING REACTION OF ZINC OXIDE AND EUGENOL
    COPELAND, HI
    BRAUER, GM
    SWEENEY, WT
    FORZIATI, AF
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1955, 55 (03): : 133 - 138
  • [6] Raman spectra of single micrometer-sized tubular ZnO
    Dong, Z. W.
    Zhang, C. F.
    Deng, H.
    You, G. J.
    Qian, S. X.
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2006, 99 (01) : 160 - 163
  • [7] Real-time Intracanal Temperature Measurement During Different Obturation Techniques
    Donnermeyer, David
    Schaefer, Edgar
    Buerklein, Sebastian
    [J]. JOURNAL OF ENDODONTICS, 2018, 44 (12) : 1832 - 1836
  • [8] Ellis B., 1993, Chemistry and Technology of Epoxy Resins, DOI DOI 10.1007/978-94-011-2932-9
  • [9] Oxidative degradation of cis- and trans-1,4-polyisoprenes and vulcanized natural rubber with enzyme-mediator systems
    Enoki, M
    Doi, Y
    Iwata, T
    [J]. BIOMACROMOLECULES, 2003, 4 (02) : 314 - 320
  • [10] Thermal analysis of commercial gutta-percha
    Ferrante, Maurizio
    Trentini, Paolo
    Croce, Fausto
    Petrini, Morena
    Spoto, Giuseppe
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2011, 103 (02) : 563 - 567