PM2.5 and SO3 collaborative removal in electrostatic precipitator

被引:65
作者
Hu Bin [1 ]
Zhang Lin [1 ]
Yi Yang [2 ]
Luo Fei [1 ]
Liang Cai [1 ]
Yang Linjun [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Key Lab Energy Thermal Convers & Control, Minist Educ, Nanjing 210096, Jiangsu, Peoples R China
[2] Wroclaw Univ Sci & Technol, Adv Mat Engn & Modelling Grp, Fac Chem, PL-50370 Wroclaw, Poland
关键词
Low temperature electrostatic precipitator; PM2.5; SO3; Simultaneous control; FIRED POWER-PLANT; COAL FLY-ASH; PARTICULATE MATTER; FLUE-GAS; COLLECTION EFFICIENCY; TEMPERATURE; NUCLEATION; EMISSIONS; VAPOR;
D O I
10.1016/j.powtec.2017.06.008
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Coal-burning pollution caused harmfully to human and environment. However, the efficiency of electrostatic precipitator (ESP) for PM2.5 is low. Reducing the ESP inlet temperature is widely concerned. This technology could simultaneously control of PM2.5 and SO3. In this study, a lab-scale low temperature ESP performance was designed under controlled conditions, the operating effects were evaluated under different temperature and SO3 concentration, SO3 and particles coagulation mechanism was discussed. Experimental results show that the operating temperature was important for ESP, The ESP outlet particle size showed a increasing trend that the median diameter d(50) increased to 0.08 mu m from 0.05 mu m, and the d(90) increased to 0.23 mu m from 0.09 mu m with the inlet temperature reduced from 150 degrees C to 90 degrees C. Particle removal efficiency increased when ESP inlet temperature reduced, especially particles with diameters of around 0.1-1 mu m increased obviously. SO3 removal efficiency improved from about 20% to above 80%, when the ESP inlet temperature drops below the acid dew point. Furthermore, SO3 binary nucleation mechanism was discussed, the analysis results of the adsorption mechanism indicated that SO3 condensation on the fly ash was mainly controlled by internal diffusion. (C) 2017 Published by Elsevier B.V.
引用
收藏
页码:484 / 490
页数:7
相关论文
共 29 条
[1]  
[Anonymous], 11 INT C EL PREC 200, P406
[2]  
[Anonymous], 2015, Measurement method of smoke and dust emission from boilers, GB/116913 2008, Patent No. 116913
[3]   Numerical modeling of electrostatic precipitation: Effect of Gas temperature [J].
Guo, Bao-Yu ;
Yu, Ai-Bing ;
Guo, Jun .
JOURNAL OF AEROSOL SCIENCE, 2014, 77 :102-115
[4]   HETEROMOLECULAR NUCLEATION IN THE SULFURIC ACID-WATER SYSTEM [J].
JACKERVOIROL, A ;
MIRABEL, P .
ATMOSPHERIC ENVIRONMENT, 1989, 23 (09) :2053-2057
[5]   HYDRATES IN SUPERSATURATED BINARY SULFURIC ACID-WATER VAPOR - A REEXAMINATION [J].
JAECKERVOIROL, A ;
MIRABEL, P ;
REISS, H .
JOURNAL OF CHEMICAL PHYSICS, 1987, 87 (08) :4849-4852
[6]   Modern electrostatic devices and methods for exhaust gas cleaning: A brief review [J].
Jaworek, Anatol ;
Krupa, Andrzej ;
Czech, Tadeusz .
JOURNAL OF ELECTROSTATICS, 2007, 65 (03) :133-155
[7]   Effect of temperature on carbon nanoparticle collection efficiency using photoelectric ESP [J].
Kim, Woojin ;
Junga, Jae Hee ;
Song, Dong Keun ;
Kim, Hakjoon ;
Kim, Yong Jin ;
Kim, Sang Soo .
SCIENCE OF THE TOTAL ENVIRONMENT, 2009, 407 (06) :2136-2141
[8]   BINARY NUCLEATION OF WATER SULFURIC-ACID SYSTEM - COMPARISON OF CLASSICAL-THEORIES WITH DIFFERENT H2SO4 SATURATION VAPOR-PRESSURES [J].
KULMALA, M ;
LAAKSONEN, A .
JOURNAL OF CHEMICAL PHYSICS, 1990, 93 (01) :696-701
[9]   Low-pressure economizer increases fly ash collection efficiency in ESP [J].
Li, Zhi-min ;
Sun, Feng-zhong ;
Ma, Lei ;
Wei, W. ;
Li, Fei .
APPLIED THERMAL ENGINEERING, 2016, 93 :509-517
[10]   Analysis and discussion on formation and control of primary particulate matter generated from coal-fired power plants [J].
Lu, Jianyi ;
Ren, Xudan .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2014, 64 (12) :1342-1351