Device-associated infection rates for non-intensive care unit patients

被引:54
|
作者
Vonberg, Ralf-Peter
Behnke, M.
Geffers, C.
Sohr, D.
Rueden, H.
Dettenkofer, M.
Gastmeier, P.
机构
[1] Hannover Med Sch, Hosp Epidemiol, Inst Med Microbiol, Div Hosp Epidemiol & Infect Control, D-30625 Hannover, Germany
[2] Hannover Med Sch, Hosp Epidemiol, Inst Med Microbiol, German Natl Reference Ctr Surveillance Nosocomial, D-3000 Hannover, Germany
[3] Humboldt Univ, Berlin, Germany
[4] Univ Hosp, Univ Med Ctr, Hosp Epidemiol, Inst Environm Med, Freiburg, Germany
来源
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY | 2006年 / 27卷 / 04期
关键词
D O I
10.1086/503339
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background. Reference data from intensive care units (ICUs) are not applicable to non-ICU patients because of the differences in device use rates, length of stay, and severity of underlying diseases among the patient populations. In contrast to the huge amount of data available for ICU patients, appropriate surveillance data for non-ICU patients have been missing in Germany. Objective. To establish a new module ('' DEVICE-KISS '') of the German Nosocomial Infection Surveillance System for generating stratified reference data for non-ICU wards. Setting. Non-ICU patients from 42 German hospitals. Methods. Monthly patient-days, device-days and nosocomial infections (NIs) ( using Centers for Disease Control and Prevention definitions) were counted. Device use rates were calculated, and NI rates were stratified by different medical specialities. Results. From July 2002 through June 2004, among the 77 wards, there were a total of 536,955 patient-days and 74,188 device- days ( for CVC-associated primary bloodstream infections, there were 181,401 patient-days and 8,317 central vascular catheter [CVC]-days in 29 wards; for urinary catheter - associated urinary tract infections, there were 445,536 patient-days and 65,871 urinary catheter-days in 65 wards) and 483 NIs ( 36 bloodstream infections and 447 urinary tract infections). The mean device use rates were 4.6 device- days per 100 patient- days for CVCs (29 wards) and 14.8 device- days per 100 patient- days for urinary catheters (65 wards), respectively. Mean deviceassociated NI rates were 4.3 infections per 1,000 CVC- days for CVC-associated bloodstream infections and 6.8 infections per 1,000 urinary catheter - days for catheter-associated urinary tract infections. Conclusions DEVICE-KISS allows non-ICUs to recognize an outlier position with regard to NIs by providing well-founded reference data for non-ICU patients.
引用
收藏
页码:357 / 361
页数:5
相关论文
共 50 条
  • [1] Evaluation and Monitoring of Device-Associated Infection Rates in Anesthesiology Intensive Care Unit
    Avci, Meltem
    Oezgenc, Onur
    Kidak, Levent B.
    Coskuner, Ayten
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2009, 29 (04): : 917 - 921
  • [2] Device-associated infection and mortality in a Tunisian intensive care unit
    N Bouafia
    M Mahjoub
    I Chouchéne
    A Bencheikh
    O Ezzi
    S Bouchoucha
    M Njah
    Antimicrobial Resistance and Infection Control, 4 (Suppl 1)
  • [3] Device-associated, device-day infection rates in an Israeli adult general intensive care unit
    Finkelstein, R
    Rabino, G
    Kassis, I
    Mahamid, E
    JOURNAL OF HOSPITAL INFECTION, 2000, 44 (03) : 200 - 205
  • [4] Device-associated nosocomial infection rates in intensive care units in Greece
    Dima, Sofia
    Kritsotakis, Evangelos I.
    Roumbelaki, Maria
    Metalidis, Simeon
    Karabinis, Andreas
    Maguina, Nina
    Klouva, Fyllis
    Levidiotou, Stamatina
    Zakynthinos, Epaminondas
    Kioumis, John
    Gikas, Achilleas
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2007, 28 (05): : 602 - 605
  • [5] Device-associated nosocomial infection rates in intensive care units of Argentina
    Rosenthal, VD
    Guzmán, S
    Crnich, C
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2004, 25 (03): : 251 - 255
  • [6] Device-associated nosocomial infection surveillance in a Turkish pediatric intensive care unit
    Sevketoglu, Esra
    Durdu, Buelent
    Acikgoz, Ozlem
    Gunay, Leyla
    Bulgur, Aysun
    Hatipoglu, Sami
    TURK PEDIATRI ARSIVI-TURKISH ARCHIVES OF PEDIATRICS, 2010, 45 (01): : 13 - 17
  • [7] Infectious complications associated with parenteral nutrition in intensive care unit and non-intensive care unit patients
    Comerlato, Pedro Henrique
    Stefani, Joel
    Viana, Marina Vercoza
    Viana, Luciana Vercoza
    BRAZILIAN JOURNAL OF INFECTIOUS DISEASES, 2020, 24 (02): : 137 - 143
  • [8] SURVEILLANCE OF DEVICE-ASSOCIATED INFECTION RATES AND MORTALITY IN 3 GREEK INTENSIVE CARE UNITS
    Apostolopoulou, Eleni
    Raftopoulos, Vasilios
    Filntisis, Georgios
    Kithreotis, Prokopis
    Stefanidis, Evagelos
    Galanis, Petros
    Veldekis, Dimitrios
    AMERICAN JOURNAL OF CRITICAL CARE, 2013, 22 (03) : E12 - E20
  • [9] Device-associated bloodstream infection rate in a neonatal intensive care unit in Saudi Arabia
    Aly, Nasser Yehia A.
    Al-Mousa, Haifaa H.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2010, 38 (06) : 495 - 496
  • [10] Device-associated infections in a paediatric intensive care unit in Pakistan
    Haque, A.
    Ahmed, S. A.
    Rafique, Z.
    Abbas, Q.
    Jurair, H.
    Ali, S. A.
    JOURNAL OF HOSPITAL INFECTION, 2017, 95 (01) : 98 - 100