Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis

被引:141
作者
Zhelev, Zhivko [1 ]
Hyde, Christopher [1 ]
Youngman, Emily [1 ]
Rogers, Morwenna [1 ]
Fleming, Simon [2 ]
Slade, Toby [3 ]
Coelho, Helen [1 ]
Jones-Hughes, Tracey [1 ]
Nikolaou, Vasilis [1 ]
机构
[1] Univ Exeter, Sch Med, Inst Hlth Res, Exeter, Devon EX2 4SG, England
[2] Royal Cornwall Hosp, Truro TQ1 3LQ, England
[3] Royal Cornwall Hosp, Emergency Dept, Truro TQ1 3LQ, England
来源
BMJ-BRITISH MEDICAL JOURNAL | 2015年 / 350卷
关键词
CORONARY-ARTERY-DISEASE; EARLY RULE-OUT; CARDIAC TROPONIN; RELATIVE CHANGES; RAPID RULE; COPEPTIN; PERFORMANCE; ABSOLUTE; PROTEIN; UTILITY;
D O I
10.1136/bmj.h15
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To obtain summary estimates of the accuracy of a single baseline measurement of the Elecsys Troponin T high-sensitive assay (Roche Diagnostics) for the diagnosis of acute myocardial infarction in patients presenting to the emergency department. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Medline, Embase, and other relevant electronic databases were searched for papers published between January 2006 and December 2013. Study selection Studies were included if they evaluated the diagnostic accuracy of a single baseline measurement of Elecsys Troponin T high-sensitive assay for the diagnosis of acute myocardial infarction in patients presenting to the emergency department with suspected acute coronary syndrome. Study appraisal and data synthesis The first author screened all titles and abstracts identified through the searches and selected all potentially relevant papers. The screening of the full texts, the data extraction, and the methodological quality assessment, using the adapted QUADAS-2 tool, were conducted independently by two reviewers with disagreements being resolved through discussion or arbitration. If appropriate, meta-analysis was conducted using the hierarchical bivariate model. Results Twenty three studies reported the performance of the evaluated assay at presentation. The results for 14 ng/L and 3-5 ng/L cut-off values were pooled separately. At 14 ng/L (20 papers), the summary sensitivity was 89.5% (95% confidence interval 86.3% to 92.1%) and the summary specificity was 77.1% (68.7% to 83.7%). At 3-5 ng/L (six papers), the summary sensitivity was 97.4% (94.9% to 98.7%) and the summary specificity was 42.4% (31.2% to 54.5%). This means that if 21 of 100 consecutive patients have the target condition (21%, the median prevalence across the studies), 2 (95% confidence interval 2 to 3) of 21 patients with acute myocardial infarction will be missed (false negatives) if 14 ng/L is used as a cut-off value and 18 (13 to 25) of 79 patients without acute myocardial infarction will test positive (false positives). If the 3-5 ng/L cut-off value is used, < 1 (0 to 1) patient with acute myocardial infarction will be missed and 46 (36 to 54) patients without acute myocardial infarction will test positive. Conclusions The results indicate that a single baseline measurement of the Elecsys Troponin T high-sensitive assay could be used to rule out acute myocardial infarction if lower cut-off values such as 3 ng/L or 5 ng/L are used. However, this method should be part of a comprehensive triage strategy and may not be appropriate for patients who present less than three hours after symptom onset. Care must also be exercised because of the higher imprecision of the evaluated assay and the greater effect of lot-to-lot reagent variation at low troponin concentrations. Systematic review registration PROSPERO registration number CRD42013003926.
引用
收藏
页数:14
相关论文
共 61 条
[1]   High-sensitivity troponin T for early rule-out of myocardial infarction in recent onset chest pain [J].
Aldous, Sally ;
Pemberton, Chris ;
Richards, A. Mark ;
Troughton, Richard ;
Than, Martin .
EMERGENCY MEDICINE JOURNAL, 2012, 29 (10) :805-810
[2]  
Aldous SJ, 2012, CLIN CHEM LAB MED, V50, P727, DOI [10.1515/CCLM.2011.830, 10.1515/cclm.2011.830]
[3]   Diagnostic and prognostic utility of early measurement with high-sensitivity troponin T assay in patients presenting with chest pain [J].
Aldous, Sally J. ;
Richards, Mark ;
Cullen, Louise ;
Troughton, Richard ;
Than, Martin .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2012, 184 (05) :E260-E268
[4]   Early Dynamic Change in High-Sensitivity Cardiac Troponin T in the Investigation of Acute Myocardial Infarction [J].
Aldous, Sally J. ;
Richards, A. Mark ;
Cullen, Louise ;
Than, Martin P. .
CLINICAL CHEMISTRY, 2011, 57 (08) :1154-1160
[5]   Comparison of high sensitivity and contemporary troponin assays for the early detection of acute myocardial infarction in the emergency department [J].
Aldous, Sally J. ;
Florkowski, Chris M. ;
Crozier, Ian G. ;
Elliott, John ;
George, Peter ;
Lainchbury, John G. ;
Mackay, Richard J. ;
Than, Martin .
ANNALS OF CLINICAL BIOCHEMISTRY, 2011, 48 :241-248
[6]  
[Anonymous], HIGH SENSITIVITY TRO
[7]  
[Anonymous], EL TROP T HIGH SENS
[8]  
[Anonymous], DIAGN TEST ACC WORK
[9]  
[Anonymous], MYOC INF AC EARL RUL
[10]  
[Anonymous], MIDAS STAT MOD MET I