Methylene blue poly(vinyl chloride) membrane electrode based on the methylene blue tetraphenylborate ion-pair complex and its application to pharmaceutical analysis

被引:0
|
作者
Wen, ML [1 ]
Chen, X [1 ]
Zhao, YB [1 ]
Wang, CY [1 ]
机构
[1] Yunnan Univ, Dept Chem, Kunming 650091, Peoples R China
关键词
methylene blue; methylene blue plastic membrane electrode; pharmaceutical analysis;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A methylene blue (MB) poly (vinyl chloride) membrane electrode based on MBtetraphenylborate (TPB) ion-pair complex is described. The linear response covers the range 1x10(-2) -1x10(-6) mof dm(-3) MB solution, with a slope of 56.5+/-0.5 mv/decade (pH range 3.0-1 0.0). The detection limit is 7.75 x 10(-7) mol dm(-3). The electrode shows' stability, good reproducibility and fast response. Interferences from common inorganic cations and some organic bases are negligible. These characteristics of the electrode enabled it to be used successfully for the determination of MB in injection.
引用
收藏
页码:1121 / 1130
页数:10
相关论文
共 37 条
  • [21] Preparation and characterization of poly(acrylic acid-co-acrylamide)/montmorillonite composite and its application for methylene blue adsorption
    Congcong Wei
    Zhiqun Xu
    Fuhao Han
    Wenkai Xu
    Junjie Gu
    Minrui Ou
    Xiaoping Xu
    Colloid and Polymer Science, 2018, 296 : 653 - 667
  • [22] Study on properties of metakaolin-based cement paste coating and its application of adsorbing methylene blue in water
    Mao, Junheng
    Wang, Qing
    Wang, Mingliang
    Li, Xiaodong
    Xu, Shuangshuang
    Shi, Zengqin
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 327
  • [23] METFORMIN-SELECTIVE POLYVINYL-CHLORIDE (PVC) MEMBRANE-ELECTRODE BASED ON THE METFORMINIUM PHOSPHOMOLYBDATE ION-PAIR
    RIZK, MS
    ELECTROANALYSIS, 1995, 7 (07) : 687 - 691
  • [24] Spectrophotometric determination of trace amounts of sulfide ion based on its catalytic reduction reaction with Methylene Blue in the presence of Te(IV)
    Mousavi, MF
    Sarlack, N
    ANALYTICAL LETTERS, 1997, 30 (08) : 1567 - 1578
  • [25] Methylene blue based near-infrared fluorogenic probe for lighting up esterase activity and its application in biological imaging
    Mei, Yu
    Yang, Haifeng
    Liu, Chengmei
    Zhang, Qian
    Zhang, Peng
    Ding, Caifeng
    DYES AND PIGMENTS, 2023, 220
  • [26] Production of non-activated biochar based on Biden pilosa and its application in removing methylene blue from aqueous solutions
    Sangsuk, Supin
    Napanya, Pinanong
    Tasen, Siwabhorn
    Baiya, Phannida
    Buathong, Chatchai
    Keeratisoontornwat, Khemissara
    Suebsiri, Sirisak
    HELIYON, 2023, 9 (05)
  • [27] Quantification of Extractable Total Per- and Polyfluoroalkyl Substances in Water Using Persulfate Preoxidation, Solid Phase Extraction, and Chemical Defluorination with Sodium Biphenyl or Ion-Pair Formation with Methylene Blue
    Cong-Hau, Nguyen
    Choi, Sangki
    Son, Heejong
    Lee, Yunho
    ACS ES&T WATER, 2024, 4 (11): : 4806 - 4817
  • [28] Development of Modified Pencil Graphite Electrode Sensors by Using Polyaniline and Polypyrrole Based Poly(acrylamide-co-amps) Hydrogels for the Detection of Methylene Blue
    Selvaraj, Ramesh
    Ganesan, Selvanathan
    Vinayagam, Elanchezhian Balachandra
    ORIENTAL JOURNAL OF CHEMISTRY, 2024, 40 (05) : 1499 - 1505
  • [29] Amperometric methylene blue-mediated sensor highly sensitive to hydrogen peroxide based on a composite membrane of regenerated silk fibroin and poly-vinyl alcohol as immobilization matrix for horseradish peroxidase
    Haiying Liu
    Jianghong Qian
    Yongcheng Liu
    Tongyin Yu
    Jiagi Deng
    Deyao Qi
    Fresenius' Journal of Analytical Chemistry, 1997, 357 : 302 - 307
  • [30] An Electrochemical Sensing Strategy for Amantadine Detection Based on Competitive Host-guest Interaction of Methylene Blue/β-cyclodextrin/Poly(N-acetylaniline) Modified Electrode
    Hao, Xia
    Li, Na
    Xu, Zhen
    Li, Nian Bing
    Luo, Hong Qun
    ELECTROANALYSIS, 2016, 28 (07) : 1489 - 1494