Ceramic matrix composite combustor liners: A summary of field evaluations

被引:64
作者
van Roode, Mark [1 ]
Price, Jeff [1 ]
Kimmel, Josh [1 ]
Miriyala, Naren [1 ]
Leroux, Don [1 ]
Fahme, Anthony [1 ]
Smith, Kenneth [1 ]
机构
[1] Solar Turbines Inc, San Diego, CA 92186 USA
来源
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME | 2007年 / 129卷 / 01期
关键词
D O I
10.1115/1.2181182
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Solar Turbines Incorporated, under U.S. government sponsored programs, has been evaluating ceramic matrix composite combustor liners in test rigs and Solars Centaur (R) 50S gas turbine engines since 1992. The objective is to evaluate and improve the performance and durability of CMCs as high-temperature materials for advanced low emissions combustors. Field testing of CMC combustor liners started in May of 1997 and by the end of 2004, over 67,000 operating hours had been accumulated on SiC/SiC and oxide/oxide CMC liners. NOx and CO emissions have been consistently < 15 ppmv and < 110 ppmv, respectively. Maximum test durations of 15,144 h and 13,937 h have been logged,for SiC/SiC liners with protective environmental barrier coatings. All oxide/oxide CMC liner with a Friable Graded Insulation coating has been tested for 12,582 h. EBCs significantly improve SiC/SiC CMC liner life. The basic three-layer EBC consists of consecutive layers of Si, mullite, and BSAS. The durability of the baseline EBC call be improved by mixing BSAS with mullite in the intermediate coating layer. The efficacy of replacing BSAS with SAS has not been demonstrated Yet. Heavy degradation was observed for two-layer Si/BSAS and Si/SAS EBCs, indicating that the elimination of the intermediate layer is detrimental to EBC durability. Equivalent performance was observed when the Hi-Nicalon fiber reinforcement was replaced with Tyranno ZM or ZMI fiber. Melt infiltrated Sic/SiC CMCs have improved durability compared to SiC/SiC CMCs fabricated by Chemical Vapor Infiltration of the matrix, in the absence of an EBC. However, the presence of all EBC results in roughly equivalent service life for MI and CVI CMCs. Results to date indicate that oxide/oxide CMCs with protective FGI show minor degradation under Centaur (R) 50S gas turbine engine operating conditions. The results of, and lessons learned from CMC combustor liner engine field testing, conducted through 2004, have been summarized.
引用
收藏
页码:21 / 30
页数:10
相关论文
共 24 条
[1]  
BRENTNALL WD, 2002, CERAMIC GAS TURBINE, V1, P155
[2]  
EATON H, 2000, 2000GT0631 ASME
[3]   CORROSION OF SILICON-BASED CERAMICS IN COMBUSTION ENVIRONMENTS [J].
JACOBSON, NS .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1993, 76 (01) :3-28
[4]  
KIMMEL J, 2003, GT20338920 ASME
[5]  
Kimmel Josh, 2005, GT200568961 ASME
[6]   Upper temperature limit of environmental barrier coatings based on mullite and BSAS [J].
Lee, KN ;
Fox, DS ;
Eldridge, JI ;
Zhu, DM ;
Robinson, RC ;
Bansal, NP ;
Miller, RA .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2003, 86 (08) :1299-1306
[7]  
Linsey G.D., 2001, 2001GT0513 ASME
[8]  
MIRIYALA N, 2001, 2001GT0512 ASME
[9]  
MIRIYALA N, 2000, 2000GT0648 ASME
[10]  
MIRIYALA N, 2002, GT200230585 ASME