Long-Term Infiltration Performance Evaluation of Dutch Permeable Pavements Using the Full-Scale Infiltration Method

被引:25
作者
Boogaard, Floris [1 ,2 ]
Lucke, Terry [3 ]
机构
[1] Hanze Univ Appl Sci, NoorderRuimte, Ctr Appl Res & Innovat Area Dev, Zernikepl 7,POB 3037, NL-9701 DA Groningen, Netherlands
[2] Energy Acad Europe, Global Ctr Adaptat, Nijenborgh 6, NL-9747 AG Groningen, Netherlands
[3] Univ Sunshine Coast, Stormwater Res Grp, Sch Sci & Engn, Sippy Downs, Qld 4558, Australia
关键词
permeable pavement; infiltration rate; clogging; full-scale test method; monitoring; QUANTITY;
D O I
10.3390/w11020320
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This research used a newly developed, full-scale infiltration testing (FSIT) procedure to determine the saturated surface infiltration rate of 16 existing permeable pavement installations in the Netherlands that have been in service for a number of years. Newly installed permeable pavements in the Netherlands must demonstrate a minimum infiltration capacity of 194 mm/h (540 L/s/ha). Only four of the 16 pavements tested in this study had an infiltration capacity higher than 194 mm/h. Most previous research has focused on unsaturated infiltration rates. However, the results of this study show that the difference in infiltration capacity between saturated and unsaturated can differ by up to 300%. If the unsaturated infiltration capacity is used as design input for computer models, the infiltration capacity may be significantly overestimated. The study demonstrated that the FSIT method is a reliable and accurate way to measure surface infiltration rates of permeable pavements. However, it is recommended that a minimum of three different FSIT tests should be undertaken at the same pavement location, and that the results should be averaged, to ensure appropriate infiltration rates are observed, recorded, and used in design. The results of this study should help stormwater managers with the planning, testing, and scheduling of maintenance requirements for permeable pavements with more confidence so that they will continue to perform satisfactorily over their intended design life.
引用
收藏
页数:13
相关论文
共 24 条
[1]  
American Society for Testing and Materials (ASTM), 2015, C1781C1781M15 ATSM
[2]   Characterization of the Infiltration Capacity of Porous Concrete Pavements with Low Constant Head Permeability Tests [J].
Andres-Valeri, Valerio C. ;
Juli-Gandara, Luis ;
Jato-Espino, Daniel ;
Rodriguez-Hernandez, Jorge .
WATER, 2018, 10 (04)
[3]  
[ASTM] American Society for Testing and Materials D3385-09, 2009, D338509 ASTM
[4]  
Bean E. Z., 2004, P 1 WAT ENV SPEC C C
[5]  
Beecham S., 2009, P 9 INT C CONCRETE B
[6]  
Boogaard F., 2017, P 14 IWA IAHR INT C
[7]   Evaluating the Infiltration Performance of Eight Dutch Permeable Pavements Using a New Full-Scale Infiltration Testing Method [J].
Boogaard, Floris ;
Lucke, Terry ;
van de Giesen, Nick ;
van de Ven, Frans .
WATER, 2014, 6 (07) :2070-2083
[8]   Effect of Age of Permeable Pavements on Their Infiltration Function [J].
Boogaard, Floris ;
Lucke, Terry ;
Beecham, Simon .
CLEAN-SOIL AIR WATER, 2014, 42 (02) :146-152
[9]  
Borgwardt S., 2006, P 8 INT C CONCR BLOC
[10]   Long-term stormwater quantity and quality performance of permeable pavement systems [J].
Brattebo, BO ;
Booth, DB .
WATER RESEARCH, 2003, 37 (18) :4369-4376