Investigation of a Modified Novel Technique in Bilateral Sagittal Splitting Osteotomy Fixation: Finite Element Analysis and In Vitro Biomechanical Test

被引:10
作者
Chang, Li-Ren [1 ,2 ]
Chen, Chien-Chung [1 ,3 ]
Jeng, Seng Feng [1 ,3 ]
Chen, Yu-Ray [4 ]
Hwang, Lain-Chyr [2 ]
Lin, Ting-Sheng [5 ]
机构
[1] E Da Hosp, Dept Plast & Reconstruct Surg, Kaohsiung, Taiwan
[2] I Shou Univ, Dept Elect Engn, Kaohsiung, Taiwan
[3] I Shou Univ, Coll Med, Kaohsiung, Taiwan
[4] Chang Gung Univ, Chang Gung Mem Hosp, Craniofacial Ctr, Dept Plast & Reconstruct Surg, Taoyuan, Taiwan
[5] I Shou Univ, Dept Biomed Engn, Kaohsiung, Taiwan
关键词
RAMUS OSTEOTOMY; SKELETAL STABILITY; MANDIBULAR ADVANCEMENT; BICORTICAL SCREWS; RIGID FIXATION; SETBACK; OSTEOSYNTHESIS; MINIPLATE; SURGERY; FORCES;
D O I
10.1155/2020/8707389
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To evaluate the biomechanical properties of the modified novel 2-hole monocortical plate fixation (2HMCPf) and traditional 4-hole monocortical plate fixation (4HMCPf) techniques in bilateral sagittal splitting osteotomy (BSSO) synthesis using a finite element analysis (FEA) and an in vitro biomechanical test with the application of a shearing loading force on a sawbone mandible model.Materials and Methods. A three-dimensional mandible models were generated using the geometry obtained from the computerized tomography image of a sawbone mandible. Plates and screws were generated and combined with the mandible in a CAD environment. The 2HMCPf and traditional 4HMCPf techniques for BSSO osteosynthesis were then analyzed under the occlusal load using the FEA. An in vitro biomechanical test was executed to verify the result of FEA. The force on fixation failure and pattern of failure were recorded.Results. The results revealed that the von Mises Stress on the mandible cortical bone (75.98 MPa) and the screw/plate (457.19 MPa) of the 2HMCPf group was lower than that of the 4HMCPf group (987.68 MPa, 1781.59 MPa). The stress concentrated on the central region of the 4HMCPf group and the distal set of the 2HMCPf group. In vitro study using the sawbone mandible model showed mechanical failure at the region of the proximal segment near the osteotomy site with the 4HMCPf group (average 32.198 N) but no failure on the fixation sites with the 2HMCPf group. Instead, the mandible sawbone fractured on the condyle neck region (average 44.953 N).Conclusion. From the biomechanical perspective, we proved that the 2HMCPf method was able to withstand a higher shearing loading force than the 4HMCPf fixation method in BSSO osteosynthesis.
引用
收藏
页数:8
相关论文
共 38 条
  • [1] SKELETAL STABILITY FOLLOWING MINIPLATE FIXATION AFTER BILATERAL SAGITTAL SPLIT OSTEOTOMY FOR MANDIBULAR ADVANCEMENT
    ABELOOS, J
    DECLERCQ, C
    NEYT, L
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (04) : 366 - 369
  • [2] Are bicortical screw and plate osteosynthesis techniques equal in providing skeletal stability with the bilateral sagittal split osteotomy when used for mandibular advancement surgery? A systematic review and meta-analysis
    Al-Moraissi, E. A.
    Al-Hendi, E. A.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (10) : 1195 - 1200
  • [3] Comparative evaluation of different fixation techniques for sagittal split ramus osteotomy in 10 mm advancements. Part two: Finite element analysis
    Alberto Sigua-Rodriguez, Eder
    Caldas, Ricardo Armini
    Goulart, Douglas Rangel
    de Moraes, Paulo Hemerson
    Olate, Sergio
    Ricardo Barao, Valentim Adelino
    de Albergaria-Barbosa, Jose Ricardo
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (07) : 1015 - 1019
  • [4] SKELETAL STABILITY AFTER MANDIBULAR ADVANCEMENT - A COMPARISON OF 2 RIGID INTERNAL-FIXATION TECHNIQUES
    BLOMQVIST, JE
    ISAKSSON, S
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1994, 52 (11) : 1133 - 1137
  • [5] An In Vitro Evaluation of Rigid Internal Fixation Techniques for Sagittal Split Ramus Osteotomies: Setback Surgery
    Brasileiro, Bernardo Ferreira
    Grotta-Grempel, Rafael
    Bovi Ambrosano, Glaucia Maria
    Passeri, Luis Augusto
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (04) : 941 - 951
  • [6] An in Vitro Evaluation of Rigid internal Fixation Techniques for Sagittal Split Ramus Osteotomies: Advancement Surgery
    Brasileiro, Bernardo Ferreira
    Grempel, Rafael Grotta
    Bovi Ambrosano, Glaucia Maria
    Passeri, Luis Augusto
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (04) : 809 - 817
  • [7] Mandibular Contouring During Orthognathic Surgery Using the Modified Hunsuck Technique
    Chen, Ying-An
    Ng, Li Shia
    Ko, Ellen Wen-Ching
    Chen, Yu-Ray
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (01) : 239 - 240
  • [8] Effect of Rigid Fixation on Orthodontic Finishing After Mandibular Bilateral Sagittal Split Setback: The Case for Miniplate Monocortical Fixation
    Cho, Heon Jae
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (04) : E310 - E321
  • [9] Postoperative stability after sagittal split ramus osteotomies for a mandibular setback with monocortical plate fixation or bicortical screw fixation
    Chung, Il-Hyuk
    Yoo, Chung-Kyu
    Lee, Eun-Kyung
    Ihm, Jong-An
    Park, Chang-Joo
    Lim, Ji-Sun
    Hwang, Kyung-Gyun
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (03) : 446 - 452
  • [10] Immediate mechanical stability of sagittal split ramus osteotomy fixed with resorbable compared with titanium bicortical screws in mandibles of sheep
    Cilasun, Ulkem
    Uckan, Sina
    Dolanmaz, Dogan
    Saglam, Haci
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2006, 44 (06) : 534 - 537