Experimental and numerical study of water-cooled datacom equipment

被引:12
作者
Douchet, Fabien [1 ,2 ]
Nortershauser, David [1 ]
Le Masson, Stepahne [1 ]
Glouannec, Patrick [2 ]
机构
[1] Orange Labs, F-22300 Lannion, France
[2] Univ Bretagne Sud, LIMATB, F-56321 Lorient, France
关键词
Data center; Cooling; Instrumentation; Heat exchanger; Energy efficiency; Numerical model; OF-THE-ART; HEAT-RECOVERY; DATA CENTERS; POWER USAGE; MANAGEMENT; EXCHANGER; CLIMATE; SYSTEMS; REUSE;
D O I
10.1016/j.applthermaleng.2015.03.030
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an experimental and numerical study of an electronic rack cooled by a finned tube heat exchanger. The objectives are to evaluate cooling and energy performance of this system and formulate a numerical model based on measurements. Experimentation has been carried out using commercial servers. A substantial instrumentation has been conducted at different scales (servers, rack and exchanger). Several tests have been made with different sets of parameters like water inlet temperature or power dissipated by servers. In each case, the heat exchanger has removed more than 90% of electrical power consumed by the rack (with no chiller use). Furthermore, promising results are obtained with this system, especially the reduction of energy consumption of cooling part compared to traditional air cooling. Finally, the rack and heat exchanger are simplified into two numerical models which can predict temperature outputs as a function of defined inputs (water and air flow rate and temperature, power dissipation). Validation tests have been carried out with different sequences of measure and numerical models have given satisfactory results. They will be duplicated to compute the impact of this cooling system at a data center room scale. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:350 / 359
页数:10
相关论文
共 33 条
[1]   Heat pipe heat exchanger for heat recovery in air conditioning [J].
Abd El-Baky, Mostafa A. ;
Mohamed, Mousa M. .
APPLIED THERMAL ENGINEERING, 2007, 27 (04) :795-801
[2]   Computational fluid dynamic investigation of liquid rack cooling in data centres [J].
Almoli, Ali ;
Thompson, Adam ;
Kapur, Nikil ;
Summers, Jonathan ;
Thompson, Harvey ;
Hannah, George .
APPLIED ENERGY, 2012, 89 (01) :150-155
[3]  
[Anonymous], 2012, PUE: A Comprehensive Examination of the Metric
[4]  
ASHRAE, 2011, ASHRAE TC 9.9
[5]  
Beck J. V., 1977, Parameter Estimation in Engineering and Science
[6]   A case study and critical assessment in calculating power usage effectiveness for a data centre [J].
Brady, Gemma A. ;
Kapur, Nikil ;
Summers, Jonathan L. ;
Thompson, Harvey M. .
ENERGY CONVERSION AND MANAGEMENT, 2013, 76 :155-161
[7]   Toward zero-emission data centers through direct reuse of thermal energy [J].
Brunschwiler, T. ;
Smith, B. ;
Ruetsche, E. ;
Michel, B. .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 2009, 53 (03)
[8]   A trust region method based on interior point techniques for nonlinear programming [J].
Byrd, RH ;
Gilbert, JC ;
Nocedal, J .
MATHEMATICAL PROGRAMMING, 2000, 89 (01) :149-185
[9]   Viability of datacenter cooling systems for energy efficiency in temperate or subtropical regions: Case study [J].
Cho, Jinkyun ;
Lim, Taesub ;
Kim, Byungseon Sean .
ENERGY AND BUILDINGS, 2012, 55 :189-197
[10]   A review of data center cooling technology, operating conditions and the corresponding low-grade waste heat recovery opportunities [J].
Ebrahimi, Khosrow ;
Jones, Gerard F. ;
Fleischer, Amy S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 31 :622-638