Study of anxiety in patients with glaucoma undergoing standard automated perimetry and optical coherence tomography - A prospective comparative study

被引:6
作者
Kaliaperumal, Subashini [1 ]
Janani, V. S. [1 ]
Menon, Vikas [2 ]
Sarkar, Sandip [1 ]
Behera, Geeta [1 ]
Kattamani, Shivanand [2 ]
机构
[1] Jawaharlal Inst Postgrad Med Educ & Res, Dept Ophthalmol, Pondicherry, India
[2] Jawaharlal Inst Postgrad Med Educ & Res, Dept Psychiat, Pondicherry, India
关键词
Anxiety; glaucoma; optical coherence tomography (OCT); State-Trait Anxiety Inventory [STAI; visual field testing;
D O I
10.4103/ijo.IJO_508_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the anxiety levels related to visual field testing and optical coherence tomography (OCT) in patients with glaucoma. Methods: This prospective, comparative study was conducted on patients with glaucoma. The participants' anxiety traits were assessed using the State-Trait Anxiety Inventory [STAI]. Before visual field testing on Humphrey visual field analyzer (HVF) and retinal nerve fiber analysis on OCT, the participants completed Form Y1 to measure the current pretest level or 'State' anxiety [pretest anxiety]. Immediately after testing, participants were administered the Form Y1 questionnaire to assess the induced anxiety level during the testing [Intratest anxiety]. Results: A total of 228 patients were enrolled with 152 participants in the HVF group and 76 in the OCT group. The mean age of the participants in the HVF group was 57.2 +/- 20.8 years and in the OCT group was 56.8 +/- 20 years. There was no significant difference in trait and pretest anxiety between the HVF group and the OCT group (P = 0.971 and P = 0.716). Intratest test anxiety score was slightly higher in the HVF group (HVF: 42.13 +/- 10.63, OCT: 40.71 +/- 9.76; P = 0.33). The anxiety scores were higher when the experience of previous HVF tests was <2 and least when the number of tests exceeded five. Conclusion: Automated perimetry induces slightly more anxiety than OCT, which may affect test performance. The measured anxiety reduces as patients gain familiarity with the test with experience. This adds credence to the recommendation of more frequent visual field testing in newly diagnosed glaucoma patients.
引用
收藏
页码:2883 / 2887
页数:5
相关论文
共 50 条
  • [1] Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics
    Dimitrios Bizios
    Anders Heijl
    Boel Bengtsson
    BMC Ophthalmology, 11
  • [2] Diagnostic Consistency and Relation Between Optical Coherence Tomography and Standard Automated Perimetry in Primary Open-Angle Glaucoma
    Toprak, Ibrahim
    Yaylali, Volkan
    Yildirim, Cem
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (02) : 185 - 190
  • [3] Agreement Among Spectral-Domain Optical Coherence Tomography, Standard Automated Perimetry, and Stereophotography in the Detection of Glaucoma Progression
    Banegas, Sebastian A.
    Anton, Alfonso
    Morilla-Grasa, Antonio
    Bogado, Marco
    Ayala, Eleonora M.
    Moreno-Montanes, Javier
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (02) : 1253 - 1260
  • [4] Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma
    Kampmeier, J
    Eisert, B
    Buchwald, HJ
    Lang, GK
    Lang, GE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (03) : 157 - 167
  • [5] Glaucoma awareness, anxiety and its impact on patients undergoing visual field testing and optical coherence tomography
    Maheshwari, Devendra
    Pillai, Madhavi Ramanatha
    Koshy, T. Nithin George
    Nagdev, Nimrita
    Gunaselvi, D. Ranitha
    Uduman, Mohammed Sithiq
    Kader, Mohideen Abdul
    Ramakrishnan, Rengappa
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2025, 35 (01) : 155 - 162
  • [6] Improving Glaucoma Detection Using Spatially Correspondent Clusters of Damage and by Combining Standard Automated Perimetry and Optical Coherence Tomography
    Raza, Ali S.
    Zhang, Xian
    De Moraes, Carlos G. V.
    Reisman, Charles A.
    Liebmann, Jeffrey M.
    Ritch, Robert
    Hood, Donald C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (01) : 612 - 624
  • [7] Glaucoma and optical coherence tomography changes in migraine: A comparative cross-sectional study
    Panicker, Gayathri
    Kaliaperumal, Subashini
    Narayan, Sunil
    Mani, Malavika
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (12) : 3546 - 3551
  • [8] A Comparison Among Microperimetry, Standard Automated Perimetry and Spectral Domain Optical Coherence Tomography in the Evaluation of the Macula in Glaucoma Eyes with Hemifield Defects
    Tian, Tian
    Cai, Yu
    Li, Mei
    Fang, Yuan
    Pan, Yingzi
    OPHTHALMOLOGY AND THERAPY, 2022, 11 (01) : 239 - 248
  • [9] A Comparison Among Microperimetry, Standard Automated Perimetry and Spectral Domain Optical Coherence Tomography in the Evaluation of the Macula in Glaucoma Eyes with Hemifield Defects
    Tian Tian
    Yu Cai
    Mei Li
    Yuan Fang
    Yingzi Pan
    Ophthalmology and Therapy, 2022, 11 : 239 - 248
  • [10] Short wave-automated perimetry (SWAP) versus optical coherence tomography in early detection of glaucoma
    Zaky, Adel Galal
    Yassin, Ahmed Tarek
    El Sayid, Saber Hamed
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 1819 - 1824