Enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples

被引:82
作者
Hashim, Nor H. [1 ,2 ]
Khan, Stuart J. [1 ]
机构
[1] Univ New S Wales, UNSW Water Res Ctr, Sch Civil & Environm Engn, Sydney, NSW, Australia
[2] Univ Tun Hussein Onn Malaysia, Batu Pahat, Malaysia
基金
澳大利亚研究理事会;
关键词
2-Arylpropionic acids; Non-steroidal anti-inflammatory drugs (NSAIDs); Enantiomeric fraction; Chiral analysis; Profens; PERFORMANCE LIQUID-CHROMATOGRAPHY; NONSTEROIDAL ANTIINFLAMMATORY DRUGS; GAS-CHROMATOGRAPHY; ACIDIC PHARMACEUTICALS; RAPID DERIVATIZATION; SEPARATION; ENANTIOMERS; ENANTIOSEPARATION; RACEMIZATION; PROPRANOLOL;
D O I
10.1016/j.chroma.2011.05.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive and reliable method for the enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples has been developed. These three pharmaceuticals are chiral molecules and the variable presence of their individual (R)- and (S)-enantiomers is of increasing interest for environmental analysis. An indirect method for enantioseparation was achieved by the derivatization of the (R)- and (S)-enantiomers to amide diastereomers using (R)-1-phenylethylamine ((R)-1-PEA). After initial solid phase extraction from aqueous samples, derivatization was undertaken at room temperature in less than 5 min. Optimum recovery and clean-up of the amide diastereomers from the derivatization solution was achieved by a second solid phase extraction step. Separation and detection of the individual diastereomers was undertaken by gas chromatography-tandem mass spectrometry (GC-MS/MS). Excellent analyte separation and peak shapes were achieved for the derivatized (R)- and (S)-enantiomers for all three pharmaceuticals with peak resolution. R-s is in the range of 2.87-4.02 for all diastereomer pairs. Furthermore, the calibration curves developed for the (S)-enantiomers revealed excellent linearity (r(2) >= 0.99) for all three compounds. Method detection limits were shown to be within the range of 0.2-3.3 ng L-1 for individual enantiomers in ultrapure water, drinking water, surface water and a synthetic wastewater. Finally, the method was shown to perform well on a real tertiary treated wastewater sample, revealing measurable concentrations of both (R)- and (S)-enantiomers of ibuprofen, naproxen and ketoprofen. Isotope dilution using racemic D-3-ibuprofen, racemic D-3-ketoprofen and racemic D-3-naproxen was shown to be an essential aspect of this method for accurate quantification and enantiomeric fraction (EF) determination. This approach produced excellent reproducibility for EF determination of triplicate tertiary treated wastewater samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4746 / 4754
页数:9
相关论文
共 36 条