O-armA®-based spinal navigation and intraoperative 3D-imaging: first experiences

被引:13
作者
Gonschorek, O. [1 ]
Hauck, S. [1 ]
Spiegl, U. [1 ]
Weiss, T. [1 ]
Paetzold, R. [1 ]
Buehren, V. [1 ]
机构
[1] BGU Murnau, Ctr Trauma, Dept Spinal Surg, D-82418 Murnau, Germany
关键词
Spinal navigation; O-arm (R); Stealth (R) station; Minimally invasive approach; 3D imaging; PEDICLE SCREW PLACEMENT; COMPUTER-ASSISTED SURGERY; IMAGE GUIDANCE; RADIATION-EXPOSURE; THORACIC SPINE; FLUOROSCOPIC NAVIGATION; C-ARM; ACCURACY; FIXATION; SYSTEM;
D O I
10.1007/s00068-011-0089-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Since the first use of instrument-tracking techniques in the early 1990s, image-guided technologies became a leading topic in all branches of spine surgery. Today, navigation is a widely available tool in spine surgery and has become a part of clinical routine in many centers for a large variety of indications. Spinal navigation may not only contribute to more precision during surgery, but it may also reduce radiation exposure and fluoroscopy time, with advantages not only for the patient but also for the operating room personnel. Different registration algorithms have been developed differing in terms of the type of image data used by the navigation system (preoperatively acquired computed tomography [CT] images, intraoperatively acquired fluoroscopy images) and the way virtual and physical reality is matched. There is a tendency toward a higher accuracy for 3D fluoroscopy-based registration algorithms. The O-arm(A (R)) represents a new flat-panel technology with the source and detector moving in a 360A degrees arc around the patient. In combination with the Stealth(A (R)) station system, navigation may start immediately after automated registration with already referenced instruments. After instrumentation, an additional scan may confirm intraoperatively the correct positioning of the instrumentation. The first experiences with the system are described in this paper.
引用
收藏
页码:99 / 108
页数:10
相关论文
共 52 条
[1]   Frameless stereotactic image-guided C1-C2 transarticular screw fixation for atlantoaxial instability - Review of 20 patients [J].
Acosta, FL ;
Quinones-Hinojosa, A ;
Gadkary, CA ;
Schmidt, MH ;
Chin, CT ;
Ames, CP ;
Rosenberg, WS ;
Weinstein, P .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (05) :385-391
[2]  
Acosta Frank L Jr, 2005, Spine J, V5, P339, DOI 10.1016/j.spinee.2004.09.012
[3]  
Arand M, 2001, Comput Aided Surg, V6, P170, DOI 10.3109/10929080109146003
[4]  
Arand M, 2002, CLIN ORTHOP RELAT R, P211
[5]  
Arand M, 2001, UNFALLCHIRURG, V104, P1076, DOI 10.1007/s001130170023
[6]   Image-guided endoscopic spine surgery - Part II: Clinical applications [J].
Assaker, R ;
Reyns, N ;
Pertruzon, B ;
Lejeune, JP .
SPINE, 2001, 26 (15) :1711-1718
[7]   Image-guided endoscopic spine surgery - Part I. A feasibility study [J].
Assaker, R ;
Cinquin, P ;
Cotten, A ;
Lejeune, JP .
SPINE, 2001, 26 (15) :1705-1710
[8]  
Battaglia Todd C, 2005, J Surg Orthop Adv, V14, P175
[9]   Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement [J].
Bloch, O ;
Holly, LT ;
Park, J ;
Obasi, C ;
Kim, K ;
Johnson, JP .
JOURNAL OF NEUROSURGERY, 2001, 95 (01) :74-79
[10]   Percutaneous transarticular atlantoaxial screw fixation using a cannulated screw system and image guidance [J].
Börm, W ;
König, RW ;
Albrecht, A ;
Richter, HP ;
Kast, E .
MINIMALLY INVASIVE NEUROSURGERY, 2004, 47 (02) :111-114