Cyclic fatigue of NiTi rotary instruments in a simulated apical abrupt curvature

被引:58
作者
Plotino, G. [1 ]
Grande, N. M. [1 ]
Melo, M. C. [2 ]
Bahia, M. G. [2 ]
Testarelli, L. [1 ]
Gambarini, G. [1 ]
机构
[1] Univ Roma La Sapienza, Dept Endodont 1, Rome, Italy
[2] Univ Fed Minas Gerais, Belo Horizonte, MG, Brazil
关键词
angle of curvature; cyclic fatigue; NiTi instruments; radius of curvature; TITANIUM ENDODONTIC INSTRUMENTS; CLINICAL-USE; BENDING STRESSES; PROTAPER; FRACTURE; SYSTEMS; PROFILE; MODELS;
D O I
10.1111/j.1365-2591.2009.01668.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
P>Aim To evaluate the cyclic fatigue resistance of five NiTi rotary systems in an abrupt apical curvature. Methodology Cyclic fatigue testing was performed in stainless-steel artificial canals with a 2-mm radius of curvature and an angle of curvature of 90 degrees constructed to the dimensions of the instruments tested. The middle of the simulated curvature was 2.5 mm from the tip of the instrument that was placed at full working length. All instruments were new and 25 mm in length. Ten ProTaper Universal F2 (Dentsply Maillefer, Ballaigues, Switzerland); FlexMaster (VDW, Munich, Germany) tip size 25, taper 0.06; Mtwo (Sweden & Martina, Padova, Italy) tip size 25, taper 0.06; ProFile tip size 25, taper 0.06 from Dentsply Maillefer (Ballaigues, Switzerland); and ProFile tip size 25, taper 0.06 from Dentsply Tulsa (Tulsa, OK, USA) were rotated passively at 300 rpm until fracture occurred, and the number of cycles to failure (NCF) recorded. Length of the fractured tip was measured. Data were analysed by one-way anova and Tukey HSD test to determine any statistical difference amongst groups. Results Mtwo had the highest fatigue resistance compared to the other instruments (NCF 124 +/- 25) (P < 0.001); there was no statistical difference between ProFile from the two different brands, although ProFile from Maillefer had the higher fatigue life (NCF 75 +/- 10) compared to ProFile from Tulsa (NCF 66 +/- 10). No difference was registered between FlexMaster (NCF 53 +/- 5) and ProFile from Tulsa; ProTaper F2 had a significantly (P < 0.001) lower fatigue life compared to the other instruments tested (NCF 29 +/- 5). Conclusions Lifespan registered for the instruments tested in an apical abrupt curvature was Mtwo > ProFile from Maillefer > ProFile from Tulsa > FlexMaster > ProTaper.
引用
收藏
页码:226 / 230
页数:5
相关论文
共 19 条
[1]   Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile [J].
Berutti, E ;
Chiandussi, G ;
Gaviglio, I ;
Ibba, A .
JOURNAL OF ENDODONTICS, 2003, 29 (01) :15-19
[2]  
Cheung G. S., 2007, ENDODONTIC TOPICS, V16, P1, DOI [10.1111/j.1601-1546.2009.00239.x, DOI 10.1111/J.1601-1546.2009.00239.X]
[3]   Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical use [J].
Fife, D ;
Gambarini, G ;
Britto, LR .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2004, 97 (02) :251-256
[4]   Cyclic fatigue of Profile rotary instruments after prolonged clinical use [J].
Gambarini, G .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (05) :386-389
[5]   Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems [J].
Grande, N. M. ;
Plotino, G. ;
Pecci, R. ;
Bedini, R. ;
Malagnino, V. A. ;
Somma, F. .
INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (10) :755-763
[6]   Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments [J].
Haïkel, Y ;
Serfaty, R ;
Bateman, G ;
Senger, B ;
Allemann, C .
JOURNAL OF ENDODONTICS, 1999, 25 (06) :434-440
[7]  
MALAGNINO VA, 1999, ITALIAN J ENDODONTIC, V13, P190
[8]  
McSpadden J T., 2007, Mastering Endodontic Instrumentation, P105
[9]   Rotary NiTi instrument fracture and its consequences [J].
Parashos, Peter ;
Messer, Harold H. .
JOURNAL OF ENDODONTICS, 2006, 32 (11) :1031-1043
[10]   Current challenges and concepts in the preparation of root canal systems: A review [J].
Peters, OA .
JOURNAL OF ENDODONTICS, 2004, 30 (08) :559-567