Vessel architecture imaging using multiband gradient-echo/spin-echo EPI

被引:16
作者
Zhang, Ke [1 ,2 ]
Yun, Seong Dae [3 ]
Triphan, Simon M. F. [4 ]
Sturm, Volker J. [1 ,2 ]
Buschle, Lukas R. [1 ,2 ]
Hahn, Artur [2 ,5 ]
Heiland, Sabine [2 ]
Bendszus, Martin [2 ]
Schlemmer, Heinz-Peter [1 ]
Shah, N. Jon [3 ,6 ]
Ziener, Christian H. [1 ,2 ]
Kurz, Felix T. [1 ,2 ]
机构
[1] German Canc Res Ctr, Dept Radiol, Heidelberg, Germany
[2] Heidelberg Univ Hosp, Dept Neuroradiol, Heidelberg, Germany
[3] Forschungszentrum Julich, Inst Neurosci & Med 4, Med Imaging Phys, Julich, Germany
[4] Heidelberg Univ Hosp, Dept Diagnost & Intervent Radiol, Heidelberg, Germany
[5] Heidelberg Univ, Dept Phys & Astron, Heidelberg, Germany
[6] Rhein Westfal TH Aachen, Dept Neurol, Fac Med, JARA, Aachen, Germany
来源
PLOS ONE | 2019年 / 14卷 / 08期
关键词
SPIN-ECHO; CONTRAST; PERFUSION; SIZE; EXCITATION; DIFFUSION; IMPACT; GRADE;
D O I
10.1371/journal.pone.0220939
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives To apply the MB (multiband) excitation and blipped-CAIPI (blipped-controlled aliasing in parallel imaging) techniques in a spin and gradient-echo (SAGE) EPI sequence to improve the slice coverage for vessel architecture imaging (VAI). Materials and methods Both MB excitation and blipped-CAIPI with in-plane parallel imaging were incorporated into a gradient-echo (GE)/spin-echo (SE) EPI sequence for simultaneous tracking of the dynamic MR signal changes in both GE and SE contrasts after the injection of contrast agent. MB and singleband (SB) excitation were compared using a 20-channel head coil at 3 Tesla, and high-resolution MB VAI could be performed in 32 glioma patients. Results Whole-brain covered high resolution VAI can be achieved after applying multiband excitation with a factor of 2 and in-plane parallel imaging with a factor of 3. The quality of the images resulting from MB acceleration was comparable to those from the SB method: images were reconstructed without any loss of spatial resolution or severe distortions. In addition, MB and SB signal-to-noise ratios (SNR) were similar. A relative low g-factor induced from the MB acceleration method was achieved after using a blipped-CAIPI technique (1.35 for GE and 1.33 for SE imaging). Performing quantitative VAI, we found that, among all VAI parametric maps, microvessel type indicator (MTI), distance map (I) and vascular-induced bolus peak-time shift (VIPS) were highly correlated. Likewise, VAI parametric maps of slope, slope length and short axis were highly correlated. Conclusions Multiband accelerated SAGE successfully doubles the number of readout slices in the same measurement time when compared to conventional readout sequences. The corresponding VAI parametric maps provide insights into the complexity and heterogeneity of vascular changes in glioma.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] MRI detection of hypointense brain lesions in patients with multiple sclerosis: T1 spin-echo vs. gradient-echo
    Dupuy, Sheena L.
    Tauhid, Shahamat
    Kim, Gloria
    Chu, Renxin
    Tummala, Subhash
    Hurwitz, Shelley
    Bakshi, Rohit
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (08) : 1564 - 1568
  • [22] Evaluation of a multiple spin- and gradient-echo (SAGE) EPI acquisition with SENSE acceleration: Applications for perfusion imaging in and outside the brain
    Skinner, Jack T.
    Robison, Ryan K.
    Elder, Christopher P.
    Newton, Allen T.
    Damon, Bruce M.
    Quarles, C. Chad
    MAGNETIC RESONANCE IMAGING, 2014, 32 (10) : 1171 - 1180
  • [23] Oscillating Gradient Spin-Echo (OGSE) Diffusion Tensor Imaging of the Human Brain
    Baron, Corey A.
    Beaulieu, Christian
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 726 - 736
  • [24] Microscopic displacement imaging with pulsed field gradient turbo spin-echo NMR
    Scheenen, TWJ
    van Dusschoten, D
    de Jager, PA
    Van As, H
    JOURNAL OF MAGNETIC RESONANCE, 2000, 142 (02) : 207 - 215
  • [25] Comparison of gradient- and spin-echo imaging: CBF, CBV, and MTT measurements by bolus tracking
    Simonsen, CZ
    Ostergaard, L
    Smith, DF
    Vestergaard-Poulsen, P
    Gyldensted, C
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (03) : 411 - 416
  • [26] FAST SPIN-ECHO IMAGING OF INTRACRANIAL NEOPLASMS
    TICE, HM
    JONES, KM
    MULKERN, RV
    SCHWARTZ, RB
    KALINA, P
    AHN, S
    BARNES, P
    JOLESZ, F
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (03) : 425 - 431
  • [27] Cardiac MR elastography using reduced-FOV, single-shot, spin-echo EPI
    Sui, Yi
    Arunachalam, Shivaram P.
    Arani, Arvin
    Trzasko, Joshua D.
    Young, Phillip M.
    Glockner, James F.
    Glaser, Kevin J.
    Lake, David S.
    McGee, Kiaran P.
    Manduca, Armando
    Rossman, Phillip J.
    Ehman, Richard L.
    Araoz, Philip A.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 231 - 238
  • [28] Sensitivity of BOLD response to increasing visual contrast: Spin echo versus gradient echo EPI
    Chiacchiaretta, Piero
    Romani, Gian Luca
    Ferretti, Antonio
    NEUROIMAGE, 2013, 82 : 35 - 43
  • [29] Resolving temporal differences of hemodynamic response with event-related spin-echo BOLD fMRI at 3T: Comparing to gradient-echo BOLD
    Yeh, Mei-Yu
    Wai, Yau-Yau
    Wan, Yung-Liang
    Liu, Ho-Ling
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 132 - 134
  • [30] Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI
    Ding, SJ
    Wolff, SD
    Epstein, FH
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) : 514 - 519