The standard addition method revisited

被引:33
作者
Andersen, Jens E. T. [1 ]
机构
[1] Botswana Int Univ Sci & Technol, Dept Chem & Forens Sci, Boseja Ward, Plot 10071,Private Bag 016, Palapye, Botswana
关键词
Quality assurance; Standard addition method (SAM); Calibration; Theory; Spectrophotometry; ATOMIC-ABSORPTION-SPECTROMETRY; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; VITAMIN-C; ASCORBIC-ACID; INSTRUMENTAL ANALYSIS; ANALYTICAL-CHEMISTRY; QUANTITATIVE-DETERMINATION; NONLINEAR CALIBRATION; EMISSION-SPECTROMETRY;
D O I
10.1016/j.trac.2016.12.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several flaws of the conventional standard-addition method (SAM) have been unravelled. By revisiting the theory, it has been shown that the SAM cannot be used to correct completely for interferences in analytical chemistry. Therefore, a new theory of SAM was developed, which takes into account the uncertainty of measurement and relates this information to differences that might stem from interferences. The SAM may be used to correct for rotational effects but it cannot be used to correct for translational effects, which confirms earlier findings. A full set of equations were supplied for undertaking a full method validation including a new set of parameters of performance. The equations were tested on determination by UV-VIS spectrophotometry of L-ascorbic acid. Previous results are reviewed and discussed in view of these new findings and recommendations are given about the importance of carrying out full method validations as a prerequisite to the SAM. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:21 / 33
页数:13
相关论文
共 68 条
[1]  
Andersen J.E.T., 2007, CHEM ANAL, V715, P715
[2]   New Concepts of Quality Assurance in Analytical Chemistry: Will They Influence the Way We Conduct Science in General? [J].
Andersen, Jens E. T. ;
Glasdam, Sidsel-Marie ;
Larsen, Daniel Bo ;
Molenaar, Nicolaas .
CHEMICAL ENGINEERING COMMUNICATIONS, 2016, 203 (12) :1582-1590
[3]   On the development of quality assurance [J].
Andersen, Jens E. T. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 60 :16-24
[4]  
Andersen JET, 2013, REV ROUM CHIM, V58, P691
[5]   Determination of iron by Z-GFAAS and the influence of short-term precision and long-term precision [J].
Andersen, Jens E. T. .
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2014, 12 (02) :194-205
[6]   The principle of pooled calibrations and outlier retainment elucidates optimum performance of ion chromatography [J].
Andersen, Jens E. T. ;
Mikolajczak, Maria ;
Wojtachnio-Zawada, Katarzyna Olga ;
Nicolajsen, Henrik Vigan .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 908 :122-127
[7]   Interpolation in the standard additions method [J].
Andrade, J. M. ;
Teran-Baamonde, J. ;
Soto-Ferreiro, R. M. ;
Carlosena, A. .
ANALYTICA CHIMICA ACTA, 2013, 780 :13-19
[9]   Determination of calcium in cereal with flame atomic absorption spectroscopy - An experiment for a quantitative methods of analysis course [J].
Bazzi, A ;
Kreuz, B ;
Fischer, J .
JOURNAL OF CHEMICAL EDUCATION, 2004, 81 (07) :1042-1044
[10]  
Beukelman T.E., 1960, APPL SPECTROSC, V14, P12, DOI DOI 10.1366/000370260774614715