Long-term effects of titanium-base abutments on peri-implant health: A 5-year randomized controlled trial
被引:0
|作者:
Rathe, Florian
[1
]
Junker, Ruediger
[2
,3
]
Heumann, Christian
Blumenroehr, Julia
Auschill, Thorsten
Arweilei, Nicole
[4
]
Schlee, Markus
[1
,5
]
机构:
[1] Privatpraxis Implantol & Parodontol, 32 Schonezahne,Bayreuther Str 39, D-91301 Forchheim, Germany
[2] Zahnmedizin Danube Private Univ, Fak Med, Steiner Landstr 124, A-3500 Krems Stein, Austria
[3] Ludwig Maximilians Univ Munchen, Inst Stat, Ludwigstr 3, D-380539 Munich, Germany
[4] Philipps Univ Marburg, Klin Parodontol & periimplantare Erkrankungen, Georg Voigt Str, Marburg, Germany
[5] Goethe Univ Frankfurt, Klin Mund, Kiefer Plast Gesichts Chirurg, Univ Klinikum Frankfurt, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
来源:
IMPLANTOLOGIE
|
2022年
/
30卷
/
04期
关键词:
abutment;
dental implant;
peri-implant bone loss;
titanium-base abutment;
ZIRCONIA;
D O I:
暂无
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Titanium bases are used frequently in daily practice for bonding to CAD/CAM abutments or crowns. Due to intimate contact between the adhesive gap of the titanium-base abutment and the peri-implant bone, the physical and chemical characteristics of the bonding material, or the gap itself, may affect peri-implant inflammatory reactions. The present study therefore aimed to examine the long-term effects of individualized abutments bonded to titanium bases on peri-implant health. A total of 24 patients, each with one test and one control abutment, participated in the present prospective, single-blind, randomized controlled clinical trial. The test abutments were CAD/CAM titanium abutments bonded to titanium bases. As the control abutments were individualized, one-piece CAD/CAM titanium abutments were used. Clinical and radiographic parameters were assessed at abutment insertion and then on a yearly basis over the following 5 years. No significant differences in marginal bone level were observed between the titanium-base and one-piece abutments at any of the follow-up time points; however, when intragroup marginal bone levels were compared to the baseline values, significant differences were found at several follow-up time points. Intergroup differences were only found to be significant for pocket depth at the 4-(P = 0.006) and 5-year follow-ups (P = 0.024), favoring titanium-base abutments. Within the limitations of the present study, it appears that the peri-implant tissues of this specific patient cohort responded to titanium-base abutments in a rather similar manner to one-piece abutments over a 5-year period; however, no definitive conclusions can be drawn due to the low power of the present study.