Optic Nerve Sheath Diameter Ultrasound and the Diagnosis of Increased Intracranial Pressure

被引:26
作者
Hylkema, Christopher [1 ,2 ]
机构
[1] Thomas Jefferson Univ, Thomas Jefferson Univ Hosp, Philadelphia, PA 19107 USA
[2] 111 South 11th St, Philadelphia, PA 19107 USA
关键词
Ultrasound; ICP; Optic nerve sheath diameter;
D O I
10.1016/j.cnc.2015.10.005
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Ultrasound has been used for almost 30 years in a wide variety of clinical applications and environments. From the austerity of battlefields to the labor and delivery ward, ultrasound has the ability to give clinicians real-time, noninvasive diagnostic imaging. Ultrasound by emergency physicians (and all nonradiologists) has become more prevalent and has been used for examinations such as the transcranial Doppler to evaluate for stroke, cardiac function, FAST and EFAST examinations for trauma, and now increased intracranial pressure (ICP) via Optic Nerve Sheath Diameter Ultrasound (ONSD). The ONSD is a valid and reliable indicator of ICP.
引用
收藏
页码:95 / +
页数:6
相关论文
共 50 条
  • [41] Optic nerve sheath diameter correlates with the presence and severity of acute mountain sickness: evidence for increased intracranial pressure
    Fagenholz, Peter J.
    Gutman, Jonathan A.
    Murray, Alice F.
    Noble, Vicki E.
    Camargo, Carlos A., Jr.
    Harris, N. Stuart
    JOURNAL OF APPLIED PHYSIOLOGY, 2009, 106 (04) : 1207 - 1211
  • [42] The Value of Bedside Ocular Ultrasound Assessment of Optic Nerve Sheath Diameter in The Detection of Increased Intracranial Pressure in Patients Presenting to the Emergency Room with Headache
    Canakci, Y.
    Koksal, O.
    Durak, V. A.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (06) : 778 - 782
  • [43] Ultrasound assessment of optic nerve sheath diameter in healthy volunteers
    Goeres, Patrick
    Zeiler, Frederick A.
    Unger, Bertram
    Karakitsos, Dimitrios
    Gillman, Lawrence M.
    JOURNAL OF CRITICAL CARE, 2016, 31 (01) : 168 - 171
  • [44] Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure
    Frumin, Erica
    Schlang, Joelle
    Wiechmann, Warren
    Hata, Stacy
    Rosen, Sasha
    Anderson, Craig
    Pare, Laura
    Rosen, Mark
    Fox, John Christian
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2014, 15 (02) : 217 - 220
  • [45] Ultrasonographic optic nerve sheath diameter as a noninvasive marker for intracranial hypotension
    Li-juan Wang
    Zhang, Ying
    Li, Cong
    Liu, Ying
    Ya-nan Dong
    Cui, Li
    Ying-qi Xin
    THERAPEUTIC ADVANCES IN NEUROLOGICAL DISORDERS, 2022, 15
  • [46] Noninvasive Transorbital Assessment of the Optic Nerve Sheath in Children: Relationship Between Optic Nerve Sheath Diameter, Deformability Index, and Intracranial Pressure
    Padayachy, Llewellyn
    Brekken, Reidar
    Fieggen, Graham
    Selbekk, Tormod
    OPERATIVE NEUROSURGERY, 2019, 16 (06) : 726 - 733
  • [47] Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults
    Chen, Han
    Ding, Gui-Sheng
    Zhao, Yan-Chun
    Yu, Rong-Guo
    Zhou, Jian-Xin
    BMC NEUROLOGY, 2015, 15
  • [48] Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults
    Han Chen
    Gui-Sheng Ding
    Yan-Chun Zhao
    Rong-Guo Yu
    Jian-Xin Zhou
    BMC Neurology, 15
  • [49] Ultrasound-measured optic nerve sheath diameter correlates well with cerebrospinal fluid pressure
    Gupta, Salil
    Pachisia, Aditya
    NEUROLOGY INDIA, 2019, 67 (03) : 772 - 776
  • [50] Optic nerve sheath diameter based on preoperative brain computed tomography and intracranial pressure are positively correlated in adults with hydrocephalus
    Lee, Hyung-Chul
    Lee, Won-Jong
    Dho, Yun-Sik
    Cho, Won-Sang
    Kim, Yong Hwy
    Park, Hee-Pyoung
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2018, 167 : 31 - 35