Optic Nerve Sheath Diameter Ultrasound and the Diagnosis of Increased Intracranial Pressure

被引:26
|
作者
Hylkema, Christopher [1 ,2 ]
机构
[1] Thomas Jefferson Univ, Thomas Jefferson Univ Hosp, Philadelphia, PA 19107 USA
[2] 111 South 11th St, Philadelphia, PA 19107 USA
关键词
Ultrasound; ICP; Optic nerve sheath diameter;
D O I
10.1016/j.cnc.2015.10.005
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Ultrasound has been used for almost 30 years in a wide variety of clinical applications and environments. From the austerity of battlefields to the labor and delivery ward, ultrasound has the ability to give clinicians real-time, noninvasive diagnostic imaging. Ultrasound by emergency physicians (and all nonradiologists) has become more prevalent and has been used for examinations such as the transcranial Doppler to evaluate for stroke, cardiac function, FAST and EFAST examinations for trauma, and now increased intracranial pressure (ICP) via Optic Nerve Sheath Diameter Ultrasound (ONSD). The ONSD is a valid and reliable indicator of ICP.
引用
收藏
页码:95 / +
页数:6
相关论文
共 50 条
  • [1] Optic nerve sheath diameter and intracranial pressure
    Dubourg, Julie
    Javouhey, Etienne
    Messerer, Mahmoud
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 570 - 571
  • [2] OPTIC NERVE SHEATH DIAMETER TO EVALUATE INCREASED INTRACRANIAL PRESSURE IN HEPATIC ENCEPHALOPATHY
    McLaughlin, Diane
    CRITICAL CARE MEDICINE, 2019, 47
  • [3] Effect of Osmotherapy on Optic Nerve Sheath Diameter in Patients with Increased Intracranial Pressure
    Launey, Yoann
    Nesseler, Nicolas
    Le Maguet, Pascale
    Malledant, Yannick
    Seguin, Philippe
    JOURNAL OF NEUROTRAUMA, 2014, 31 (10) : 984 - 988
  • [4] Effect of intracranial pressure on the diameter of the optic nerve sheath
    Watanabe, Arata
    Kinouchi, Hiroyuki
    Horikoshi, Toru
    Uchida, Mikito
    Ishigame, Keiichi
    JOURNAL OF NEUROSURGERY, 2008, 109 (02) : 255 - 258
  • [5] Optic nerve sheath diameter and intracranial pressure RESPONSE
    Driessen, Caroline
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 571 - 571
  • [6] Evaluation of Increased Intracranial Pressure with the Optic Nerve Sheath Diameter by Ultrasound in Epiduroscopic Neural Laser Discectomy Procedures
    Beyaz, Serbulent Gokhan
    Kaya, Burak
    Ulgen, Ali Metin
    Sahin, Fatih
    Kocayigit, Havva
    Issi, Zeynep Tuncer
    PAIN PHYSICIAN, 2021, 24 (05) : E595 - E600
  • [7] Optic Nerve Sheath Diameter Evaluation With Two Ultrasound Techniques in Patients at Risk for Increased Intracranial Pressure Reply
    Agrawal, Ashish
    Cheng, Roger
    Tang, Julin
    Madhok, Debbie Y.
    CRITICAL CARE MEDICINE, 2019, 47 (09) : E787 - E787
  • [8] Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs
    Mija, R.
    Zubak, I
    Schuetz, A.
    Glas, M.
    Fung, C.
    Jakob, S. M.
    Beck, J.
    Z'Graggen, W. J.
    Bloch, Andreas
    PLOS ONE, 2020, 15 (02):
  • [9] Optic nerve sheath diameter/eyeball transverse diameter ratio by ultrasound in prediction of increased intracranial pressure in children with viral encephalitis
    Zhao, Chun
    Sun, Peng-Cheng
    Fang, Ke-Jie
    Fu, Hui-Hui
    Wei, Li-Feng
    Miao, Yin-Yun
    Guo, Xin-Xin
    Weng, Xiao-Ling
    FRONTIERS IN PEDIATRICS, 2025, 12
  • [10] Optic Nerve Sheath Diameter Correlation with Elevated Intracranial Pressure Determined via Ultrasound
    Munawar, Kamran
    Khan, Muhammad Tariq
    Hussain, Syed Waqar
    Qadeer, Aayesha
    Shad, Zahid Siddique
    Bano, Sheher
    Abdullah, Azmat
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (02)