Novel 3D heart left ventricle muscle segmentation method for PET-gated protocol and its verification

被引:2
|
作者
Kubik, Tomasz [1 ,2 ]
Kaluzynski, Krzysztof [1 ]
Burger, Cyrill [2 ]
Passeri, Alessandro [3 ]
Margiacchi, Selene [3 ]
Saletti, Paola [4 ]
Bonini, Rita [5 ]
Lorenzini, Elena [6 ]
Sciagra, Roberto [3 ]
机构
[1] Warsaw Univ Technol, Fac Mechatron, Inst Metrol & Biomed Engn, Ul Sw Andrzeja Boboli 8, PL-02525 Warsaw, Poland
[2] Pmod Technol LLC, Sumatrastr 25, CH-8006 Zurich, Switzerland
[3] Univ Florence, ECBSD, Nucl Med, Largo Brambilla 3, I-50134 Florence, Italy
[4] AOU Careggi, Med Phys, Largo Brambilla 3, I-50134 Florence, Italy
[5] ASL Nord Ovest, Nucl Med, Via Risorgimento 18, I-54100 Massa, Italy
[6] ASL Nord Ovest, Med Phys, Piazza Sacco & Vanzetti 5, I-54033 Carrara, Italy
关键词
Segmentation method; Gated PET imaging; Volume quantification; left ventricle; cardiology; MYOCARDIAL BLOOD-FLOW; ACTIVE CONTOURS; IMAGE SEGMENTATION; QUANTIFICATION; AMMONIA; TRACER;
D O I
10.1007/s12149-019-01373-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveThe aim of this study was to propose and verify a universal method of left ventricular myocardium segmentation, able to operate on heart gated PET data with different sizes, shapes and uptake distributions. The proposed method can be classified as active model method and is based on the BEAS (B-spline Explicit Active Surface) algorithm published by Barbosa et al. The method was implemented within the Pmod PCARD software package. Method verification by comparison with reference software and phantom data is also presented in the paper.MethodsThe proposed method extends the BEAS model by defining mechanical features of the model: tensile strength and bending resistance. Formulas describing model internal energy increase during its stretching and bending are proposed. The segmentation model was applied to the data of 60 patients, who had undergone cardiac gated PET scanning. QGS by Cedars-Sinai and ECTb by Emory University Medical Centre served as reference software for comparing ventricular volumes. The method was also verified using data of left ventricular phantoms of known volume.ResultsThe results of the proposed method are well correlated with the results of QGS (slope: 0.841, intercept: 0.944ml, R-2: 0.867) and ECTb (slope: 0.830, intercept: 2.109ml, R-2: 0.845). The volumes calculated by the proposed method were very close to the true cavity volumes of two different phantoms.ConclusionsThe analysis of gated PET data by the proposed method results in volume measurements comparable to established methods. Phantom experiments demonstrate that the volume values correspond to the physical ones.
引用
收藏
页码:629 / 638
页数:10
相关论文
共 50 条
  • [1] Novel 3D heart left ventricle muscle segmentation method for PET-gated protocol and its verification
    Tomasz Kubik
    Krzysztof Kałużyński
    Cyrill Burger
    Alessandro Passeri
    Selene Margiacchi
    Paola Saletti
    Rita Bonini
    Elena Lorenzini
    Roberto Sciagrà
    Annals of Nuclear Medicine, 2019, 33 : 629 - 638
  • [2] A 3D Tool for Left Ventricle Segmentation Editing
    Silva, Samuel
    Santos, Beatriz Sousa
    Madeira, Joaquim
    Silva, Augusto
    IMAGE ANALYSIS AND RECOGNITION, 2010, PT II, PROCEEDINGS, 2010, 6112 : 79 - 88
  • [3] Segmentation of the Left Ventricle in 3D Echocardiographic Images and Simultaneous Visualization Using the 3D Texture Method
    Bosnjak, Antonio
    Montilla, Guillermo
    Villegas, Hyxia
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2349 - 2352
  • [4] 3D reconstruction of the left ventricle by triangulation method
    Souag, N
    PROCEEDINGS OF THE IEEE-ISIE 2004, VOLS 1 AND 2, 2004, : 293 - 297
  • [5] A Novel Method for Respiratory Motion Gated With Geometric Sensitivity of the Scanner in 3D PET
    He, Jianfeng
    O'Keefe, Graeme J.
    Gong, Sylvia Jie
    Jones, Gareth
    Saunder, Tim
    Scott, Andrew M.
    Geso, Moshi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2557 - 2565
  • [6] Deep Atlas Network for Efficient 3D Left Ventricle Segmentation on Echocardiography
    Dong, Suyu
    Luo, Gongning
    Tam, Clara
    Wang, Wei
    Wang, Kuanquan
    Cao, Shaodong
    Chen, Bo
    Zhang, Henggui
    Li, Shuo
    MEDICAL IMAGE ANALYSIS, 2020, 61
  • [7] Robust 3D Active Shape Model for the Segmentation of the Left Ventricle in MRI
    Santiago, Carlos
    Nascimento, Jacinto C.
    Marques, Jorge S.
    PATTERN RECOGNITION AND IMAGE ANALYSIS (IBPRIA 2015), 2015, 9117 : 283 - 290
  • [8] An automatic segmentation method with self-attention mechanism on left ventricle in gated PET/CT myocardial perfusion imaging
    Zhang, Yangmei
    Wang, Fanghu
    Wu, Huiqin
    Yang, Yuling
    Xu, Weiping
    Wang, Shuxia
    Chen, Wufan
    Lu, Lijun
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 229
  • [9] Multi-frame Attention Network for Left Ventricle Segmentation in 3D Echocardiography
    Ahn, Shawn S.
    Ta, Kevinminh
    Thorn, Stephanie
    Langdon, Jonathan
    Sinusas, Albert J.
    Duncan, James S.
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT I, 2021, 12901 : 348 - 357
  • [10] 3D active shape model matching for left ventricle segmentation in cardiac CT
    van Assen, HC
    van der Geest, RJ
    Danilouchkine, MG
    Lamb, HJ
    Reiber, JHC
    Lelieveldt, BPF
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 384 - 393