Analyses of the V1000CT-1 benchmark with the DYN3D/ATHLET and DYN3D/RELAP coupled code systems including a coolant mixing model validated against CFD calculations

被引:21
作者
Kliem, S. [1 ]
Kozmenkov, Y. [1 ]
Hoehne, T. [1 ]
Rohde, U. [1 ]
机构
[1] Forschungszentrum Rossendorf EV, Inst Safety Res, D-01314 Dresden, Germany
关键词
coupled code systems; 3D neutron kinetics; code validation; VVER-1000; coolant transient benchmark;
D O I
10.1016/j.pnucene.2006.06.008
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Plant-measured data provided within the specification of the OECD/NEAVVER-1000 coolant transient benchmark (V1000CT) were used to validate the DYN3D/RELAP5 and DYN3D/ATHLET coupled code systems. Phase I of the benchmark (V1000CT-1) refers to the MCP (main coolant pump) switching on experiment conducted in the frame of the plant-commissioning activities at the Kozloduy NPP Unit 6 in Bulgaria. The experiment was started at the beginning of cycle (BOC) with average core expose of 30.7 effective full power days (EFPD), when the reactor power was at 27.5% of the nominal level and three out of four MCPs were operating. The transient is characterized by a rapid increase in the primary coolant flow through the core and, as a consequence, a decrease of the space-dependent core inlet temperature. Both DYN3D/RELAP5 and DYN3D/ATHLET analyses were based on the same reactor model, including identical MCP characteristics, boundary conditions, benchmark-specified nuclear data library and nearly identical nodalization schemes. For an adequate modelling of the redistribution of the coolant flow in the reactor pressure vessel during the transient a simplified mixing model for the DYN3D/ATHLET code was developed and validated against a computational fluid dynamics calculation. The results of both coupled code calculations are in good agreement with the available experimental data. The discrepancies between experimental data and the results of both coupled code calculations do not exceed the accuracy of the measurement data. This concerns the initial steady-state data as well as the time histories during the transient. In addition to the validation of the coupled code systems against measured data, a code-to-code comparison between simulation results has been performed to evaluate relevant thermal hydraulic models of the system codes RELAP5 and ATHLET and to explain differences between the calculation results. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:830 / 848
页数:19
相关论文
共 17 条
  • [1] *ANSYS CFX, 2005, CFX571 ANSYSCFX
  • [2] *BPG, 2001, ERCOFTAC BEST PRACT
  • [3] Analysis of the Boiling Water Reactor Turbine Trip Benchmark with the codes DYN3D and ATHLET/DYN3D
    Grundmann, U
    Kliem, S
    Rohde, U
    [J]. NUCLEAR SCIENCE AND ENGINEERING, 2004, 148 (02) : 226 - 234
  • [4] Grundmann U., 2000, P 2000 ANS INT TOP M
  • [5] Grundmann U., 1998, FZR216
  • [6] Grundmann U., 1995, P INT C MATH COMPUTA, V1, P257
  • [7] Validation of coupled neutron kinetic/thermal-hydraulic codes.: Part 2:: Analysis of a VVER-440 transient (Loviisa-1)
    Hämäläinen, A
    Kyrki-Rajamäki, R
    Mittag, S
    Kliem, S
    Weiss, FP
    Langenbuch, S
    Danilin, S
    Hadek, J
    Hegyi, G
    [J]. ANNALS OF NUCLEAR ENERGY, 2002, 29 (03) : 255 - 269
  • [8] IVANOV B, 2003, MAIN COOLANT PUMP MC, V1
  • [9] KOLEV N, 2004, VVER 1000 COOLANT TR, V2
  • [10] Kozmenkov Y., 2001, P ANN M NUCL TECHN D, P15