Regulation-controlling of boundary layer by multi-wire-to-cylinder negative corona discharge

被引:21
作者
Wang, Wei [1 ]
Yang, Lanjun [1 ]
Wu, Kai [1 ]
Lin, Cen [1 ]
Huo, Peng [2 ]
Liu, Shuai [1 ]
Huang, Dong [1 ]
Lin, Mei [3 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian, Peoples R China
[2] Xian High Voltage Apparat Res Inst, Xian, Peoples R China
[3] Xi An Jiao Tong Univ, Natl Specialty Lab Fluid Machinery, Xian, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrohydrodynamic; Boundary layer; Field synergy; Heat transfer enhancement; HEAT-TRANSFER ENHANCEMENT; EHD GAS PUMP; AIR-FLOW; ELECTROSTATIC PRECIPITATOR; EFFICIENCY CHARACTERISTICS; FORCED-CONVECTION; FLAT-PLATE; IONIC WIND; VELOCITY; PLASMA;
D O I
10.1016/j.applthermaleng.2017.03.092
中图分类号
O414.1 [热力学];
学科分类号
摘要
Multi-wire-to-cylinder corona discharge was studied for better understanding of the electrohydrodynamic phenomena which directly relate to the performance of heat transfer enhancement. A unipolar approximation model was established and numerical simulations were conducted to determinate the heat transfer and velocity distribution of ionic wind. The numerical and experiments results show good agreement. It indicates that higher applied voltage and more corona wires can help decreasing thermal boundary layer thickness and increasing velocity gradient of boundary layer, resulting in the enhancement of heat transfer. When the applied voltage increases from -7 kV to -11 kV and the number of wire increases from corona wire number 1-3, there will be a 39.8% decrease of the thickness of thermal boundary layer. In the condition of U = -11 kV, the maximum local forced convection heat transfer coefficient for corona wire number N = 3 is 12 times and the average value is 8 times higher than that of natural convection. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:438 / 448
页数:11
相关论文
共 46 条
[1]   SIMULATION OF CORONA IN WIRE-DUCT ELECTROSTATIC PRECIPITATOR BY MEANS OF THE BOUNDARY-ELEMENT METHOD [J].
ADAMIAK, K .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1994, 30 (02) :381-386
[2]  
[Anonymous], 2015, Electromagnetic Theory
[3]   Electrical and mechanical characteristics of surface AC dielectric barrier discharge plasma actuators applied to airflow control [J].
Benard, Nicolas ;
Moreau, Eric .
EXPERIMENTS IN FLUIDS, 2014, 55 (11)
[4]  
Boulos M. I., 1994, THERMAL PLASMAS FUND, DOI [10.1007/978-3-319-12183-3_1-2, DOI 10.1007/978-3-319-12183-3_1-2]
[5]  
Cengel YA., 1998, HEAT TRANSFER PRACTI
[6]   Model of the negative DC corona plasma: Comparison to the positive DC corona plasma [J].
Chen, JH ;
Davidson, JH .
PLASMA CHEMISTRY AND PLASMA PROCESSING, 2003, 23 (01) :83-102
[7]  
Colas D., 2010, 63 ANN GAS EL C 7 IN
[8]   Ionic wind generation by a wire-cylinder-plate corona discharge in air at atmospheric pressure [J].
Colas, Dorian F. ;
Ferret, Antoine ;
Pai, David Z. ;
Lacoste, Deanna A. ;
Laux, Christophe O. .
JOURNAL OF APPLIED PHYSICS, 2010, 108 (10)
[9]   Ionic winds for locally enhanced cooling [J].
Go, David B. ;
Garimella, Suresh V. ;
Fisher, Timothy S. ;
Mongia, Rajiv K. .
JOURNAL OF APPLIED PHYSICS, 2007, 102 (05)
[10]   Enhancement of external forced convection by ionic wind [J].
Go, David B. ;
Maturana, Raul A. ;
Fisher, Timothy S. ;
Garimella, Suresh V. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (25-26) :6047-6053