Right Hepatic Vein Stenosis at Anastomosis in Patients after Living Donor Liver Transplantation: Optimal Doppler US Venous Pulsatility Index and CT Criteria-Receiver Operating Characteristic Analysis

被引:18
作者
Hwang, Hye Jeon [1 ,2 ]
Kim, Kyoung Won [1 ,2 ]
Jeong, Woo Kyoung [4 ]
Song, Gi-Won [3 ]
Ko, Gi-Young [1 ,2 ]
Sung, Kyu Bo [1 ,2 ]
Shin, Yong Moon [1 ,2 ]
Kim, Pyo Nyun [1 ,2 ]
Ha, Tae-Yong [3 ]
Moon, Deok-Bog [3 ]
Kim, Ki-Hun [3 ]
Ahn, Chul-Soo [3 ]
Hwang, Shin [3 ]
Lee, Sung-Gyu [3 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, Seoul 138736, South Korea
[3] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Liver Transplantat Surg, Seoul 138736, South Korea
[4] Hanyang Univ, Guri Hosp, Dept Radiol, Guri, South Korea
关键词
RIGHT-LOBE GRAFT; BALLOON ANGIOPLASTY; ENDOVASCULAR TREATMENT; OUTFLOW OBSTRUCTION; WAVE-FORM; CONGESTION; RECIPIENTS; RECONSTRUCTION; REJECTION;
D O I
10.1148/radiol.2532081858
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To establish optimal Doppler ultrasonographic (US) venous pulsatility index and computed tomographic (CT) criteria for right hepatic vein (RHV) stenosis after living donor liver transplantation (LDLT) and to compare accuracies of these methods by using receiver operating characteristic (ROC) analysis. Materials and Methods: This retrospective study was approved by an institutional review board; informed consent was waived. Eighty patients (48 men, 32 women; mean age, 51.5 years +/- 9.2 [standard deviation]) underwent Doppler US and CT within 8 days of hepatic venography following right lobe LDLT between October 2006 and September 2008. At venography, RHVs were classified into a stenosis or nonstenosis group. At Doppler US, venous pulsatility index was defined as the difference between maximum and minimum frequency shifts divided by maximum frequency shift. At CT, diameters of anastomosis and RHV were measured; percentage of stenosis was calculated. Mean Doppler US and CT parameters in the two groups were compared; ROC analysis was performed. Results: There were 30 stenotic and 50 nonstenotic RHVs. Mean venous pulsatility index and mean anastomosis diameter were significantly lower and mean percentage of stenosis was significantly higher in the stenosis than the nonstenosis group (P < .001 each). Optimal cutoffs for venous pulsatility index, anastomosis diameter, and percentage of stenosis were 0.16, 3.7 mm, and 47%, respectively. Sensitivity and specificity were 86.7% and 68.0% for venous pulsatility index, 96.7% and 88.0% for anastomosis diameter, and 96.7% and 86.0% for percentage of stenosis, respectively. At ROC analysis, anastomosis diameter (P = .002) and percentage of stenosis (P = .003) were significantly more accurate than venous pulsatility index. Conclusion: CT is more accurate than Doppler US for RHV stenosis after LDLT, with venous pulsatility index as the sole sonographic criterion. Patients suspected of having RHV stenosis at Doppler US may benefit from CT to reduce unnecessary venography. (C) RSNA, 2009
引用
收藏
页码:543 / 551
页数:9
相关论文
共 24 条
[11]   Doppler sonographic abnormalities suggestive of venous congestion in the right lobe graft of living donor liver transplant recipients [J].
Kim, Kyoung Won ;
Kim, Tae Kyoung ;
Kim, So Yeon ;
Kim, Min-Jeong ;
Park, Mi-Suk ;
Lee, Moon-Gyu ;
Lee, Sung Gyu .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (03) :W239-W245
[12]   Impact of graft size mismatching on graft prognosis in liver transplantation from living donors [J].
Kiuchi, T ;
Kasahara, M ;
Uryuhara, K ;
Inomata, Y ;
Uemoto, S ;
Asonuma, K ;
Egawa, H ;
Fujita, S ;
Hayashi, M ;
Tanaka, K .
TRANSPLANTATION, 1999, 67 (02) :321-327
[13]   Hepatic vein stenosis after living donor liver transplantation: Evaluation with Doppler US [J].
Ko, EY ;
Kim, TK ;
Kim, PN ;
Kim, AY ;
Ha, HK ;
Lee, MG .
RADIOLOGY, 2003, 229 (03) :806-810
[14]   Endovascular treatment of hepatic venous outflow obstruction after living-donor liver transplantation [J].
Ko, GY ;
Sung, KB ;
Yoon, HK ;
Kim, JH ;
Song, HY ;
Seo, TS ;
Lee, SG .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (06) :591-599
[15]   Effect of respiration on the spectral Doppler wave of the right hepatic vein in right lobe living donor liver transplant recipients [J].
Lee, Seung Soo ;
Kim, Kyoung Won ;
Park, Beorn Jin ;
Shin, Yong Moon ;
Kim, Pyo Nyun ;
Lee, Moon-Gyu ;
Lee, Sung Gyu .
JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (12) :1723-1733
[16]   Techniques of reconstruction of hepatic veins in living-donor liver transplantation, especially for right hepatic vein and major short hepatic veins of right-lobe graft [J].
Lee, SG .
JOURNAL OF HEPATO-BILIARY-PANCREATIC SURGERY, 2006, 13 (02) :131-138
[17]   Early postoperative complications following liver transplantation [J].
Mueller, AR ;
Platz, KP ;
Kremer, B .
BEST PRACTICE & RESEARCH CLINICAL GASTROENTEROLOGY, 2004, 18 (05) :881-900
[18]   EFFECT OF TEMPORARY OCCLUSION OF THE HEPATIC VEIN ON DUAL BLOOD-SUPPLY IN THE LIVER - EVALUATION WITH SPIRAL CT [J].
MURATA, S ;
ITAI, Y ;
ASATO, M ;
KOBAYASHI, H ;
NAKAJIMA, K ;
EGUCHI, N ;
SAIDA, Y ;
KURAMOTO, K ;
TOHNO, E .
RADIOLOGY, 1995, 197 (02) :351-356
[19]   Hepatic venous congestion after right-lobe living-donor liver transplantation: The added value of delayed-phase imaging on CT [J].
Park, Eun-Ah ;
Lee, Jeong Min ;
Kim, Se Hyung ;
Lee, Min Woo ;
Han, Joon Koo ;
Choi, Byung Ihn ;
Lee, Jae Young ;
Lee, Whal ;
Chung, Jin Wook ;
Park, Jae Hyung .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (02) :181-187
[20]   STENOSES OF VASCULAR ANASTOMOSES AFTER HEPATIC TRANSPLANTATION - TREATMENT WITH BALLOON ANGIOPLASTY [J].
RABY, N ;
KARANI, J ;
THOMAS, S ;
OGRADY, J ;
WILLIAMS, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :167-171