Electro-oxidation of nimesulide at 5% barium-doped zinc oxide nanoparticle modified glassy carbon electrode

被引:72
作者
Bukkitgar, Shikandar D. [1 ]
Shetti, Nagaraj P. [1 ]
Kulkarni, Raviraj M. [2 ]
Doddamani, Mrityunjay R. [3 ]
机构
[1] Visvesvaraya Technol Univ, KLE Inst Technol, Dept Chem, Hubli 580030, Karnataka, India
[2] Visveswaraya Technol Univ, KLS Gogte Inst Technol, Dept Chem, Belagavi 590008, Karnataka, India
[3] Natl Inst Technol, Mech Engn, Surathkal 575025, Karnataka, India
关键词
Nimesulide; Voltammetry; 5% Barium-doped zinc oxide nano particles; Oxidation; Drug analysis; LOOP DIURETIC FUROSEMIDE; ELECTROCHEMICAL OXIDATION; PASTE ELECTRODE; BEHAVIOR; UPDATE;
D O I
10.1016/j.jelechem.2015.12.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Development of methods for the detection of an analyte at low concentration with less time for analysis has become a prior point of interest to every analyst. In reflection of this fact, an effort has been made to synthesize 5% barium doped zinc oxide nanoparticles and was characterized by using XRD, EDX, SEM, and TEM. Further, 5% barium doped zinc oxide nanoparticle modified glassy carbon electrode was used for investigating the electro-chemical behavior of nimesulide. Voltammograms obtained in a range of 3.0-112 (I = 0.2 M) pH had a maximum peak current at pH 7.0. Various physio-chemical parameters such as, process on the surface of the electrode, which was found to be diffusion controlled, heterogeneous rate constant, number of electrons transferred and charge transfer coefficient were estimated. Further, a method for nimesulide determination in a linear range of 1.0 x 10(-5) to 1.0 x 10(-7) M with LOD 1.794 nM was proposed. This technique was later used for analytical application. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 34 条
[1]  
Adamovics J.A., 1997, Chromatographic Analysis of Pharmaceuticals, V2nd
[2]  
Ahuja S., 2001, Handbook of Modern Pharmaceutical Analysis
[3]   Clinical pharmacokinetics and metabolism of nimesulide [J].
Alberto Bernareggi .
InflammoPharmacology, 2001, 9 (1-2) :81-89
[4]  
BROWN ER, 1964, PHYS METHODS CHEM, P423
[5]   Electro-sensing base for mefenamic acid on a 5% barium-doped zinc oxide nanoparticle modified electrode and its analytical application [J].
Bukkitgar, S. D. ;
Shetti, N. P. ;
Kulkarni, R. M. ;
Nandibewoor, S. T. .
RSC ADVANCES, 2015, 5 (127) :104891-104899
[6]   Flow amperometric determination of pharmaceuticals with on-line electrode surface renewal [J].
Catarino, RIL ;
Conceiçao, ACL ;
Garcia, MBQ ;
Gonçalves, MLS ;
Lima, JLFC ;
dos Santos, MMC .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (04) :571-580
[7]  
Chawal M., 2010, J PHARM PHARMACOL, V52, P467
[8]  
Christian G.D., 1962, JELECTROANAL CHEM, V3, P363
[9]  
Constantinescu IC, 2009, FARMACIA, V57, P267
[10]  
Cullity BD., 2001, Elementary of X-Ray Diffraction, V3