A TECHNIQUE TO VERIFY OR CORRECT ANALOGUE POSITION AND SOFT TISSUE PROFILE ON AN IMPLANT WORKING CAST

被引:14
作者
Di Vitale, Nicola [1 ]
Tung, Francis [1 ]
Goldstein, Gary [1 ]
机构
[1] NYU, Coll Dent, Dept Prosthodont, New York, NY 10010 USA
关键词
SUPPORTED PROSTHESES; VERIFICATION JIG; IMPRESSION; ACCURACY;
D O I
10.1016/S0022-3913(09)00098-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A procedure which allows verification of the implant working cast and a method to correct the position of one or more implant analogues, if necessary, is described. In a single procedure, a corrected, accurate cast with soft tissue profile can be obtained by using a polyether impression material in conjunction with an acrylic resin Jig. (J Prosthet Dent 2009;102:137-139)
引用
收藏
页码:137 / 139
页数:3
相关论文
共 15 条
[1]  
Assuncao Wirley Goncalves, 2004, Implant Dent, V13, P358
[2]  
Barrett M G, 1993, J Prosthodont, V2, P75
[3]  
Carr A B, 1991, Int J Oral Maxillofac Implants, V6, P448
[4]   Verification jig for implant-supported prostheses: A comparison of standard impressions with verification jigs made of different materials [J].
De la Cruz, JE ;
Funkenbusch, PD ;
Ercoli, C ;
Moss, ME ;
Graser, GN ;
Tallents, RH .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (03) :329-336
[5]  
Del'Acqua MA, 2008, INT J ORAL MAX IMPL, V23, P226
[6]  
HUMPHRIES R M, 1990, International Journal of Oral and Maxillofacial Implants, V5, P331
[7]   AN IMPRESSION TECHNIQUE FOR OSSEOINTEGRATED IMPLANTS [J].
IVANHOE, JR ;
ADRIAN, ED ;
KRANTZ, WA ;
EDGE, MJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1991, 66 (03) :410-411
[8]   IMPLANT TRANSFER COPING VERIFICATION JIG [J].
KNUDSON, RC ;
WILLIAMS, EO ;
KEMPLE, KP .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 61 (05) :601-602
[9]   SEGMENTAL FRAMEWORK MATRIX - MASTER CAST VERIFICATION, CORRECTED CAST GUIDE, AND ANALOG TRANSFER TEMPLATE FOR IMPLANT-SUPPORTED PROSTHESES [J].
MCCARTNEY, JW ;
PEARSON, R .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (02) :197-200
[10]  
Naconecy MM, 2004, INT J ORAL MAX IMPL, V19, P192