Reducing radiation exposure during procedures performed in the electrophysiology laboratory

被引:12
作者
Thibault, Bernard [1 ,2 ]
Macle, Laurent [1 ,2 ]
Mondesert, Blandine [1 ,2 ]
Dubuc, Marc [1 ,2 ]
Shohoudi, Azadeh [3 ]
Dyrda, Katia [1 ,2 ]
Guerra, Peter G. [1 ,2 ]
Rivard, Lena [1 ,2 ]
Roy, Denis [1 ,2 ]
Talajic, Mario [1 ,2 ]
Khairy, Paul [1 ,2 ]
机构
[1] Univ Montreal, Montreal Heart Inst, Electrophysiol Serv, Montreal, PQ, Canada
[2] Univ Montreal, Dept Med, Montreal, PQ, Canada
[3] Univ Montreal, Montreal Hlth Innovat Coordinating Ctr, Montreal Heart Innovat Coordinating Ctr, Montrel Heart Inst, Montreal, PQ, Canada
关键词
cardiac implantable electronic device; catheter ablation; fluoroscopy; interventional electrophysiology; radiation exposure; radiation safety; CARDIAC RESYNCHRONIZATION THERAPY; ATRIAL-FIBRILLATION ABLATION; CATHETER TRACKING SYSTEM; IMAGE INTEGRATION MODULE; PULMONARY VEIN ISOLATION; INITIAL-EXPERIENCE; INTERVENTIONAL CARDIOLOGY; RANDOMIZED-TRIAL; IMPLANTATION; PATIENT;
D O I
10.1111/jce.13373
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Expert societies recently published strong recommendations to reduce the exposure of patients and staff to ionizing radiation (IR) during interventional and electrophysiology (EP) procedures. However, adherence to these guidelines remains difficult and the impact of implementing such recommendations is poorly characterized. Methods and results: We conducted a single-center cohort study to quantify radiation exposure over time in three EP laboratories at the Montreal Heart Institute during 5,546 consecutive procedures from 2012 to 2015 by 11 primary operators. Overall, 2,618 (47.2%) procedures were catheter-based and 2,928 (52.8%) were device interventions. Interventions to reduce radiation exposure included educational initiatives to raise awareness (i.e., limiting cine acquisition, patient position, table height), slower frame rate, lower radiation dose per pulse, collimation, and integration with 3-D mapping systems and/or MediGuide technology. An 85% reduction in IR exposure was observed from 2012 to 2015, with the mean dose-area-product (DAP) decreasing from 7.65 +/- 0.05 Gy.cm(2) to 1.15 +/- 0.04 Gy.cm(2) (P < 0.001). This was true for catheter-based procedures (mean DAP 16.99 +/- 0.08 to 2.00 +/- 0.06 Gy.cm(2), P < 0.001) and device interventions (mean DAP 4.18 +/- 0.06 to 0.64 +/- 0.05 Gy.cm(2), P < 0.001). The median effective dose of IR recorded per quarter by 282 cervical dosimeters on EP staff decreased from 0.57 (IQR 0.18, 1.03) mSv in 2012 to 0.00 (IQR 0.00, 0.19) mSv in 2015, P < 0.001. Conclusion: Enforcing good clinical practices with simple measures and low-dose fluoroscopy settings are highly effective in reducing IR exposure in the EP lab. These promising results should encourage other EP labs to adopt similar protective measures.
引用
收藏
页码:308 / 315
页数:8
相关论文
共 35 条
  • [1] Measures to Reduce Radiation in a Modern Cardiac Catheterization Laboratory
    Agarwal, Shikhar
    Parashar, Akhil
    Ellis, Stephen G.
    Heupler, Frederick A., Jr.
    Lau, Evan
    Tuzcu, E. Murat
    Kapadia, Samir R.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (04) : 447 - +
  • [2] Relationship of Beam Angulation and Radiation Exposure in the Cardiac Catheterization Laboratory
    Agarwal, Shikhar
    Parashar, Akhil
    Bajaj, Navkaranbir Singh
    Khan, Imran
    Ahmad, Imran
    Heupler, Fredrick A., Jr.
    Bunte, Matthew
    Modi, Dhruv K.
    Tuzcu, E. Murat
    Kapadia, Samir R.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (05) : 558 - 566
  • [3] Reduction of Radiation Exposure in Atrial Fibrillation Ablation Using a New Image Integration Module: A Prospective Randomized Trial in Patients Undergoing Pulmonary Vein Isolation
    Akbulak, Ruken Oezge
    Schaeffer, Benjamin
    Jularic, Mario
    Moser, Julia
    Schreiber, Doreen
    Salzbrunn, Tim
    Meyer, Christian
    Eickholt, Christian
    Kuklik, Pawel
    Hoffmann, Boris A.
    Willems, Stephan
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (07) : 747 - 753
  • [4] Predictive factors of difficult implantation procedure in cardiac resynchronization therapy
    Bisch, Laurence
    Da Costa, Antoine
    Dauphinot, Virginie
    Romeyer-Bouchard, Cecile
    Khris, Lila
    M'Baye, Alassane
    Isaaz, Karl
    [J]. EUROPACE, 2010, 12 (08): : 1141 - 1148
  • [5] The European cardiac resynchronization therapy survey: patient selection and implantation practice vary according to centre volume
    Bogale, Nigussie
    Priori, Silvia
    Gitt, Anselm
    Alings, Marco
    Linde, Cecilia
    Dickstein, Kenneth
    [J]. EUROPACE, 2011, 13 (10): : 1445 - 1453
  • [6] Reducing operator radiation exposure during cardiac resynchronization therapy
    Brambilla, Marco
    Occhetta, Eraldo
    Ronconi, Martina
    Plebani, Laura
    Carriero, Alessandro
    Marino, Paolo
    [J]. EUROPACE, 2010, 12 (12): : 1769 - 1773
  • [7] Radiation Exposure of Patient and Physician during Implantation and Upgrade of Cardiac Resynchronization Devices
    Butter, Christian
    Schau, Thomas
    Meyhoefer, Juergen
    Neumann, Klaus
    Minden, Hans H.
    Engelhardt, Joerg
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (08): : 1003 - 1012
  • [8] Initial Experience with a New Image Integration Module Designed for Reducing Radiation Exposure During Electrophysiological Ablation Procedures
    Cano, Oscar
    Alonso, Pau
    Osca, Joaquin
    Andres, Ana
    Sancho-Tello, Maria-Jose
    Olaguee, Jose
    Salvador, Antonio
    Martinez-Dolz, Luis
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (06) : 662 - 670
  • [9] Near zerO fluoroscopic exPosure during catheter ablAtion of supRavenTricular arrhYthmias: the NO-PARTY multicentre randomized trial
    Casella, Michela
    Dello Russo, Antonio
    Pelargonio, Gemma
    Del Greco, Maurizio
    Zingarini, Gianluca
    Piacenti, Marcello
    Di Cori, Andrea
    Casula, Victor
    Marini, Massimiliano
    Pizzamiglio, Francesca
    Zucchetti, Martina
    Riva, Stefania
    Russo, Eleonora
    Narducci, Maria Lucia
    Soldati, Ezio
    Panchetti, Luca
    Startari, Umberto
    Bencardino, Gianluigi
    Perna, Francesco
    Santangeli, Pasquale
    Di Biase, Luigi
    Cichocki, Fabrizio
    Fattore, Giovanni
    Bongiorni, Mariagrazia
    Picano, Eugenio
    Natale, Andrea
    Tondo, Claudio
    [J]. EUROPACE, 2016, 18 (10): : 1565 - 1572
  • [10] Fluoroscopy integrated 3D mapping significantly reduces radiation exposure during ablation for a wide spectrum of cardiac arrhythmias
    Christoph, Marian
    Wunderlich, Carsten
    Moebius, Stefanie
    Forkmann, Mathias
    Sitzy, Judith
    Salmas, Jozef
    Mayer, Julia
    Huo, Yan
    Piorkowski, Christopher
    Gaspar, Thomas
    [J]. EUROPACE, 2015, 17 (06): : 928 - 937