Angiographic CT with Intravenous Contrast Injection Compared with Conventional Rotational Angiography in the Diagnostic Work-Up of Cerebral Aneurysms

被引:16
作者
Goelitz, P. [1 ]
Struffert, T. [1 ]
Knossalla, F. [2 ]
Saake, M. [1 ]
Ott, S. [1 ]
Ganslandt, O. [3 ]
Doerfler, A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Neuroradiol, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Neurol, D-91052 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Neurosurg, D-91052 Erlangen, Germany
关键词
DIGITAL-SUBTRACTION-ANGIOGRAPHY; INTRACRANIAL ANEURYSMS; ACCURACY; IMAGES; MRA; TOMOGRAPHY;
D O I
10.3174/ajnr.A2883
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Noninvasive imaging of cerebral aneurysms is still considered inferior to conventional angiography. The purpose of this study was to evaluate the diagnostic accuracy of ivACT in the assessment of intracranial aneurysms compared with 3D-DSA. MATERIALS AND METHODS: We included 13 patients with 15 incidental unruptured saccular aneurysms scheduled for diagnostic angiographic work-up in our study. In each patient, we performed an ivACT and a conventional angiography including a 3D rotational run. During postprocessing, MPR images were generated for each technique. Maximal aneurysm diameter, neck diameter, aneurysm height, maximum width, bulge height, parent artery diameter, and angle between the parent artery and aneurysm apex were measured for each aneurysm. RESULTS: 3D-DSA and ivACT both provided images of high quality without artificial disturbances (ie, motion artifacts). Measurements of all parameters resulted in comparable values for both modalities with a strong correlation (P <= .001). CONCLUSIONS: ivACT is feasible for the noninvasive visualization of saccular cerebral aneurysms and may provide reliable diagnostic information for the assessment of aneurysm size and geometry comparable with conventional intra-arterial 3D rotational angiography. These preliminary results might be a first promising step to replacing conventional angiography in preinterventional aneurysm imaging.
引用
收藏
页码:982 / 987
页数:6
相关论文
共 24 条
[1]  
Adams WM, 2000, AM J NEURORADIOL, V21, P1618
[2]   Intracranial aneurysms: Clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment [J].
Anxionnat, R ;
Bracard, S ;
Ducrocq, X ;
Trousset, Y ;
Launay, L ;
Kerrien, E ;
Braun, M ;
Vaillant, R ;
Scomazzoni, F ;
Lebedinsky, A ;
Picard, L .
RADIOLOGY, 2001, 218 (03) :799-808
[3]   Medical progress: Cerebral aneurysms [J].
Brisman, Jonathan L. ;
Song, Joon K. ;
Newell, David W. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (09) :928-939
[4]   Retreatment of ruptured cerebral aneurysms in patients randomized by coiling or clipping in the international subarachnoid aneurysm trial (ISAT) [J].
Campi, Adriana ;
Ramzi, Najib ;
Molyneux, Andrew J. ;
Summers, Paul E. ;
Kerr, Richard S. C. ;
Sneade, Mary ;
Yarnold, Julia A. ;
Rischmiller, Joan ;
Byrne, James V. .
STROKE, 2007, 38 (05) :1538-1544
[5]   Comparison of computed tomographic angiography with digital subtraction angiography in the diagnosis of cerebral aneurysms: A meta-analysis [J].
Chappell, ET ;
Moure, FC ;
Good, MC .
NEUROSURGERY, 2003, 52 (03) :624-630
[6]   Complications of Modern Diagnostic Cerebral Angiography in an Academic Medical Center [J].
Fifi, Johanna T. ;
Meyers, Philip M. ;
Lavine, Sean D. ;
Cox, Virginia ;
Silverberg, Lynn ;
Mangla, Sundeep ;
Pile-Spellman, John .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (04) :442-447
[7]   Bottleneck factor and height-width ratio: Association with ruptured aneurysms in patients with multiple cerebral aneurysms [J].
Hoh, Brian L. ;
Sistrom, Christopher L. ;
Firment, Christopher S. ;
Fautheree, Gregory L. ;
Velat, Gregory J. ;
Whiting, Jobyna H. ;
Reavey-Cantwell, John F. ;
Lewis, Stephen B. .
NEUROSURGERY, 2007, 61 (04) :716-722
[8]   Detection of intracranial aneurysms: Multi-detector row CT angiography compared with DSA [J].
Jayaraman, MV ;
Mayo-Smith, WW ;
Tung, GA ;
Haas, RA ;
Rogg, JM ;
Mehta, NR ;
Doberstein, CE .
RADIOLOGY, 2004, 230 (02) :510-518
[9]   Intracranial aneurysms: evaluation using CTA and MRA. Correlation with DSA and intraoperative findings [J].
Kouskouras, C ;
Charitanti, A ;
Giavroglou, C ;
Foroglou, N ;
Selviaridis, P ;
Kontopoulos, V ;
Dimitriadis, AS .
NEURORADIOLOGY, 2004, 46 (10) :842-850
[10]   Neuroradiologic Applications with Routine C-arm Flat Panel Detector CT: Evaluation of Patient Dose Measurements [J].
Kyriakou, Y. ;
Richter, G. ;
Doerfler, A. ;
Kalender, W. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (10) :1930-1936