Impedance labelless detection-based polypyrrole protein biosensor

被引:71
作者
Li, CM
Chen, W
Yang, X
Sun, CQ
Gao, C
Zheng, ZX
Sawyer, J
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 639798, Singapore
[2] Cent China Normal Univ, Coll Life Sci, Wuhan 430079, Peoples R China
[3] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[4] Motorola Life Sci, Tempe, AZ 85287 USA
来源
FRONTIERS IN BIOSCIENCE-LANDMARK | 2005年 / 10卷
关键词
polypyrrole electrode; protein biosensor; labelless detection; impedance measurements; immunosensors;
D O I
10.2741/1716
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A simple and sensitive electrochemical immunosensor with impedance labelless detection and novel data processing method was investigated. One-step polymerization was used to electrochemically deposit an antibody impregnated polypyrrole film on a glassy carbon electrode surface for the immunosensor. Impedance measurements provided a labelless or reporterless method to detect antibody ( Ab)-antigen (Ag) interactions. Dimensionless analysis was employed to successfully process the measured impedance data. Since the method derived unit impedance change to eliminate or reduce the variation of the bulk electronic properties of Ab/polypyrrole films, the signal to noise ratio (S/N) was significantly improved for high sensitivity and specificity. Nonspecific binding effect was studied by array electrode chips and was found out that the polypyrrole electrode without antibody attachment had much stronger nonspecific binding effect than the Ab/polypyrrole electrode; incubation followed by thoroughly washing significantly reduced the nonspecific interference. 10 pg/ml detection limit and superior specificity were achieved by the method, demonstrating a highly sensitive labelless immunosensor in comparison with the detection limit of ng -mu g/ml for the reported polypyrrole based immunosensors. The electrochemical immunosensors presented in this paper, due to its simplicity, low cost, high sensitivity and superior specificity, could be an invaluable tool for clinical diagnostics and could have potential applications in drug discovery, environmental and food analysis.
引用
收藏
页码:2518 / 2526
页数:9
相关论文
共 44 条
  • [11] F Allen J Bard L.R., 2001, Electrochemical Methods: Fundamentals and Applications
  • [12] Functional characterization of a conducting polymer-based immunoassay system
    Fare, TL
    Cabelli, MD
    Dallas, SM
    Herzog, DP
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) : 459 - 470
  • [13] ENZYME RECOGNITION BY POLYPYRROLE FUNCTIONALIZED WITH BIOACTIVE PEPTIDES
    GARNIER, F
    YOUSSOUFI, HK
    SRIVASTAVA, P
    YASSAR, A
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (19) : 8813 - 8814
  • [14] REAL-TIME MONITORING OF IMMUNOCHEMICAL INTERACTIONS WITH A TANTALUM CAPACITANCE FLOW-THROUGH CELL
    GEBBERT, A
    ALVAREZICAZA, M
    STOCKLEIN, W
    SCHMID, RD
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (09) : 997 - 1003
  • [15] Immunosensors: Electrochemical sensing and other engineering approaches
    Ghindilis, AL
    Atanasov, P
    Wilkins, M
    Wilkins, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (01) : 113 - 131
  • [16] SIMULTANEOUS IMMUNOASSAY USING ELECTROCHEMICAL DETECTION OF METAL-ION LABELS
    HAYES, FJ
    HALSALL, HB
    HEINEMAN, WR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (11) : 1860 - 1865
  • [17] DEVELOPMENT OF A POLYPYRROLE-BASED HUMAN SERUM-ALBUMIN SENSOR
    JOHN, R
    SPENCER, M
    WALLACE, GG
    SMYTH, MR
    [J]. ANALYTICA CHIMICA ACTA, 1991, 249 (02) : 381 - 385
  • [18] POLYPYRROLE - AN ELECTROCHEMICALLY SYNTHESIZED CONDUCTING ORGANIC POLYMER
    KANAZAWA, KK
    DIAZ, AF
    GILL, WD
    GRANT, PM
    STREET, GB
    GARDINI, GP
    [J]. SYNTHETIC METALS, 1980, 1 (03) : 329 - 336
  • [19] ELECTROCHEMICAL ENZYME-IMMUNOASSAY USING SEQUENTIAL SATURATION TECHNIQUE IN A 20-MUL CAPILLARY - DIGOXIN AS A MODEL ANALYTE
    KANEKI, N
    XU, Y
    KUMARI, A
    HALSALL, HB
    HEINEMAN, WR
    KISSINGER, PT
    [J]. ANALYTICA CHIMICA ACTA, 1994, 287 (03) : 253 - 258
  • [20] Conductimetric immunosensor based on poly( 3,4-ethylenedioxythiophene)
    Kanungo, M
    Srivastava, DN
    Kumar, A
    Contractor, AQ
    [J]. CHEMICAL COMMUNICATIONS, 2002, (07) : 680 - 681