Optimisation of acoustic emission wavestreaming for structural health monitoring

被引:15
作者
McCrory, John P. [1 ]
Pearson, Matthew R. [1 ]
Pullin, Rhys [1 ]
Holford, Karen M. [1 ]
机构
[1] Cardiff Univ, Sch Engn, Cardiff CF24 3AA, Wales
来源
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL | 2020年 / 19卷 / 06期
关键词
Structural health monitoring; acoustic emission; wavestreaming; optimisation; fatigue; cracking; SOURCE LOCATION; FATIGUE; PROPAGATION; MECHANISMS; STEEL;
D O I
10.1177/1475921720912174
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Structural health monitoring has gained wide appeal for applications with high inspection costs, such as aircraft and wind turbines. As the structures and materials used in these industries evolve, so too must the technologies used to monitor them. Acoustic emission is a passive method of detecting damage which lends itself well to structural health monitoring. One form of acoustic emission monitoring, known as wavestreaming, involves intermittently recording data for set periods of time and using the sequential recordings to detect changes in the state of the structure. However, at present, there is no standard method for selecting appropriate wavestream recording parameters, such as their length or their interval of collection. This article investigates a method of optimising acoustic emission wavestreaming for structural health monitoring purposes by introducing the novel concept of adjoining consecutive discrete acoustic emission hit signals to create synthetic wavestreams. To this end, a pre-notched 492 mm x 67.5 mm x 20 mm, 300M grade steel cantilever specimen was subject to cyclic loading and both acoustic emission hit data and conventional wavestreams were collected as a crack grew in the notched region; crack growth activity was also monitored using digital image correlation for comparison. To demonstrate the proposed optimisation process, four sets of synthetic wavestreams were created from the hit data, 0.25, 0.5, 1.0 and 1.5 s in length, and compared with the 1.5-s-long conventional wavestreams. The activity of the peak frequency and frequency centroid bands of interest within the conventional and synthetic wavestreams were examined to determine whether or not cracking activity could be inferred through them. Across comparisons of all data, it was found that the 0.5-s-long synthetic wavestreams contained enough information to identify the same trends as the conventional wavestreams for this application; thus, the use of synthetic wavestreams as a tool for selecting an appropriate wavestream recording length was demonstrated.
引用
收藏
页码:2007 / 2022
页数:16
相关论文
共 48 条
[1]  
Aggelis D.G., 2011, J. Acoust. Emiss, V29, P113
[2]  
Al-Ghamdi AM, 2004, P 26 EUR C AC EM TES
[3]   Delta T source location for acoustic emission [J].
Baxter, Matthew Geoffrey ;
Pullin, Rhys ;
Holford, Karen M. ;
Evans, Sam L. .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2007, 21 (03) :1512-1520
[4]   The signatures of acoustic emission waveforms from fatigue crack advancing in thin metallic plates [J].
Bhuiyan, Md Yeasin ;
Giurgiutiu, Victor .
SMART MATERIALS AND STRUCTURES, 2018, 27 (01)
[5]  
Buttle D. J., 1990, Journal of Acoustic Emission, V9, P243
[6]  
Buttle D. J., 1990, Journal of Acoustic Emission, V9, P255
[7]  
COX BN, 1986, FATIGUE FRACT ENG M, V9, P435, DOI 10.1111/j.1460-2695.1987.tb00470.x
[8]   Gear tooth root fatigue test monitoring with continuous acoustic emission: Advanced signal processing techniques for detection of incipient failure [J].
Crivelli, Davide ;
McCrory, John ;
Miccoli, Stefano ;
Pullin, Rhys ;
Clarke, Alastair .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2018, 17 (03) :423-433
[9]   Acoustic emission source location in composite materials using Delta T Mapping [J].
Eaton, M. J. ;
Pullin, R. ;
Holford, K. M. .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2012, 43 (06) :856-863
[10]  
Eaton MJ, 2014, P 16 EUR C COMP MAT, P22