Reliable, Accurate Determination of the Leukocyte Differential of Leukopenic Samples by Using Hematoflow Method

被引:17
作者
Jo, Yongjun [1 ]
Kim, Soo Hwa [1 ]
Koh, Kwangsang [1 ]
Park, Jongmoon [1 ]
Shim, Yang Bo [1 ]
Lim, Jihyang [1 ]
Kim, Yonggoo [1 ]
Park, Yeon-Joon [1 ]
Han, Kyungja [1 ]
机构
[1] Catholic Univ Korea Coll Med, Dept Lab Med, Seoul 137701, South Korea
来源
KOREAN JOURNAL OF LABORATORY MEDICINE | 2011年 / 31卷 / 03期
关键词
Hematoflow; Cytodiff; Leukopenia; Flow cytometry; Hematology cell analyzer; FLOW-CYTOMETRY; ACUTE-LEUKEMIA; BLOOD;
D O I
10.3343/kjlm.2011.31.3.131
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Hematology analyzers may ineffectively recognize abnormal cells, and manual differential counts may be imprecise for leukopenic samples. We evaluated the efficacy of the Hematoflow method for determining the leukocyte differential in leukopenic samples and compared this method with the manual differential method. Methods: We selected 249 blood samples from 167 patients with leukopenia (WBC counts, 500-2,000/mu L) for analysis in this study. The EDTA-anticoagulated blood samples were analyzed using an automatic blood cell counter (DxH800; Beckman Coulter, USA) and flow cytometry (FC 500; Beckman Coulter) by using Cytodiff reagent and analysis software (Beckman Coulter). Hematoflow results were selected or calculated from DxH800 and Cytodiff results. Two trained pathologists performed a manual differential count by counting 50-100 cells. Results:The precision of the Hematoflow method was superior to that of the manual method in counting 5 leukocyte subpopulations, immature granulocytes (IGs), and blasts. Blasts were detected in all 45 cases (100%) by Hematoflow. The correlation of the Cytodiff blast count to the reference count was high (r = 0.8325). For all other cell populations, the correlation of the Hematoflow results with the reference count was stronger than that of the other manual counts with the reference count. Conclusions: The Hematoflow differential counting method is more reproducible and sensitive than manual counting, and is relatively easy to perform. In particular, this method detected leukemic blasts more sensitively than manual differential counts. The Hematoflow method is a very useful supplement to automated cell counting.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 21 条
  • [1] Prophylaxis of chemotherapy-induced febrile neutropenia with granulocyte colony-stimulating factors: where are we now?
    Aapro, Matti
    Crawford, Jeffrey
    Kamioner, Didier
    [J]. SUPPORTIVE CARE IN CANCER, 2010, 18 (05) : 529 - 541
  • [2] Barnes P W, 2005, Lab Hematol, V11, P83, DOI 10.1532/LH96.05019
  • [3] Total nucleated cell differential for blood and bone marrow using a single tube in a five-color flow cytometer
    Bjornsson, Sven
    Wahlstrom, Saga
    Norstrom, Eva
    Bernevi, Ingela
    O'Neill, Ulla
    Johansson, Eva
    Runstrom, Hakan
    Simonsson, Per
    [J]. CYTOMETRY PART B-CLINICAL CYTOMETRY, 2008, 74B (02) : 91 - 103
  • [4] Campana D, 1999, CYTOMETRY, V38, P139, DOI 10.1002/(SICI)1097-0320(19990815)38:4<139::AID-CYTO1>3.0.CO
  • [5] 2-H
  • [6] Evaluation of an 8-Color Flow Cytometric Reference Method for White Blood Cell Differential Enumeration
    Cherian, Sindhu
    Levin, Greg
    Lo, Wing Yin
    Mauck, Megan
    Kuhn, Donald
    Lee, Crystol
    Wood, Brent L.
    [J]. CYTOMETRY PART B-CLINICAL CYTOMETRY, 2010, 78B (05) : 319 - 328
  • [7] 6 markers/5 colors extended white blood cell differential by flow cytornetry
    Faucher, Jean-Luc
    Lacronique-Gazaille, Charlotte
    Frebet, Elise
    Trimoreau, Franck
    Donnard, Magali
    Bordessoule, Dominique
    Lacombe, Francis
    Feuillard, Jean
    [J]. CYTOMETRY PART A, 2007, 71A (11) : 934 - 944
  • [8] Between-examiner reproducibility in manual differential leukocyte counting
    Fuentes-Arderiu, Xavier
    Garcia-Panyella, Mariona
    Dot-Bach, Dolors
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 2007, 12 (12) : 643 - 645
  • [9] Performance evaluation of the PENTRA 60C+ automated hematology analyzer and comparison with the ADVIA 2120
    Guerti, K.
    Vertessen, F.
    Daniels, L.
    Van der Planken, M.
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2009, 31 (02) : 132 - 141
  • [10] JEAN A, 2010, INT J LAB HEMAT 0816